5
Alternatively use citric acid crystals
(available from most pharmacies) as
f
ollows.
1 F
ill the kettle 3/4 full, boil, then
unplug the kettle (remove the
cordless kettle from the base unit)
a
nd stand it in an empty sink or
bowl.
2 Add 50gm of citric acid crystals to
t
he water gradually, then leave the
kettle to stand. Do not use a more
c
oncentrated solution.
3 As soon as the effervescence
subsides, empty the kettle and rinse
it thoroughly with cold water.
4 Wipe the outside of the kettle
thoroughly with a damp cloth to
remove all traces of acid which may
damage the finish.
IMPORTANT: Ensure that the
electrical connections are
completely dry before using the
kettle.
Cleaning
WARNING: Always disconnect
the plug from the mains and
allow the kettle to cool before
cleaning.
Wipe the outside with a damp cloth.
IMPORTANT: Do not use abrasive
cleaners on the outside of the kettle
which may scratch the surface.
YOUR TWO-YEAR
GUARANTEE
This appliance is covered by two-
year repair or replacement warranty.
It is important to retain the retailers
receipt as proof of purchase. Staple
your receipt to this back cover for
future reference.
Please quote the following
information if the product develops
a fault. These numbers can be
found on the base of the pr
oduct.
Model no.
Serial no.
All Morphy Richards products are
individually tested before leaving the
factory. In the unlikely event of any
appliance proving to be faulty within
28 days of purchase it should be
r
eturned to the place of purchase
f
or it to be replaced.
If the fault develops after 28 days
and within 24 months of original
p
urchase, you should contact
Morphy Richards quoting Model
number and Serial number on the
product, or write to Morphy
R
ichards at the address shown.
Y
ou will be asked to return the
product (in secure, adequate
packaging) to the address below
along with a copy of proof of
purchase.
Subject to the exclusions set out
below (1-6) the faulty appliance will
then be repaired or replaced and
dispatched usually within 7 working
days of receipt.
If for any reason this item is
replaced during the 2-year
guarantee period, the guarantee on
the new item will be calculated from
original purchase date. Therefore it
is vital to retain your original till
receipt or invoice to indicate the
date of initial purchase.
To qualify for the 2-year guarantee
the appliance must have been used
according to the manufacturers
instructions. For example,
appliances must have been
descaled and filters must have been
kept clean as instructed.
Morphy Richards shall not be liable
to replace or repair the goods under
the terms of the guarantee where:
1 The fault has been caused or is
attributable to accidental use,
misuse, negligent use or used
contrary to the manufacturers
recommendations or where the fault
has been caused by power surges
or damage caused in transit.
2 The appliance has been used on a
voltage supply other than that
stamped on the products.
3
Repairs have been attempted by
persons other than our service staff
(or authorised dealer).
4 Where the appliance has been used
for hire purposes or non domestic
use.
g
4
Features
A
⁄
Lid
¤ Lid knob
‹ Spout filter
› Concealed element
fi 360°connector
fl Cordless base unit
‡ Cord storage
· On/off switch
‚ Power on neon
„ Water level indicator
Using
Filling the kettle
1
Wherever possible fill through the
spout, as this helps to free the filter
from limescale build-up.
• The integrated water level indicator
allows you to easily see the amount
of water in the kettle.
• Always ensure that the level of
water in the kettle is filled to at least
the minimum level shown on the
water gauge. Should your kettle not
have a water gauge, always ensure
that the element is covered.
• Boil only as much water as you
need as this saves electricity.
2 Place the kettle on the base unit,
ensuring the kettle locates on to the
360° connector.
•
The 360
°
connector allows the
kettle to be located at any position.
- ideal for left and right handed
users and for convenient positioning
on the worktop.
3 Plug in and switch on at the wall
socket.
4 Switch the kettle on. The ‘power on’
neon will light up.
5 W
hen the water boils the kettle will
s
witch off automatically.
• If you are using the kettle for the
f
irst time, pour away the boiled
water and refill.
6 Lift the kettle from the base unit by
t
he handle ensuring you hold the
kettle level.
• To re-boil, switch to ON again. If the
kettle has just switched off wait a
minute or so before switching it
back on again.
• If you do not put in enough water, or
switch on the kettle when it is
empty, the safety cut-out will switch
off the power automatically. If this
happens, refill and wait a few
minutes for the element to cool,
then use as normal.
Filter removal
1 Open the lid.
2 Lift the filter upwards from its
holder.
3 To refit the filter, slide it into the side
wall guides of the filter holder until it
clicks into place.
WARNING: Unless the filter is
fitted correctly, the kettle lid
may not close and lock
securely.
Descaling
IMPORTANT: As this kettle is fitted
with a concealed element it must be
descaled regularly. The frequency of
descaling depends on usage and
the hardness of the water in your
area.
Excessive scale can cause the
kettle to switch off before boiling
and may damage the element
invalidating the warranty
.
It is essential that regular descaling
takes place.
Remove hard scale using a
proprietary descaling product
suitable for stainless steel kettles.
⁄
¤
›
fi
fl
‚
‡
·
„‹
A