Holding registers
Data type Description Data Default Values
1Device slave address unsigned int. Modbus device address 1—247 1
2Modbus baud rate unsigned int. Modbus communication baud rate 0—6 2
0 =
1 =
2 =
3 =
4 =
5 =
6 =
4.800
9.600
19.200
38.400
57.600
115.200
230.400
3Modbus parity mode unsigned int. Parity check mode 0 =
1 =
2 =
8N1
8E1
8O1 10 =
1 =
2 =
None
Even
Odd
4Device type unsigned int. Device type (Read-only) ALR -M1 = 2200
5HW version unsigned int. Hardware version of the device
(Read-only) XXXX 0 x 0100
= HW version 1.00
6FW version unsigned int. Firmware version of the device
(Read-only) XXXX 0 x 0110
= FW version 1.00
7–10 Reserved, return “0”
11 Рабочий режим unsigned int. Mode of operation 0—3 0
0 =
1 =
2 =
3 =
OK (green LED is ON)
Warning (yellow LED is ON)
Alarm (red LED and buzzer are
ON)
Custom (next 4 registers are
allowed)
12 Green LED unsigned int. Direct control green LED (allowed
in Custom operating mode only) 0—1 0 0 =
1 = OFF
ON
13 Yellow LED unsigned int. Direct control yellow LED (allowed
in Custom operating mode only) 0—1 0 0 =
1 = OFF
ON
14 Red LED unsigned int. Direct control red LED (allowed in
Custom operating mode only) 0—1 0 0 =
1 = OFF
ON
15 Режим работы
зуммера unsigned int. Buzzer control (allowed in Custom
operating mode only) 0—1 0 0 =
1 = OFF
ON
16 Sound mode unsigned int. Pulsing / continuous sound 0—1 0 0 =
1 = pulsing
continuous
17 Start-up action unsigned int. Start up indication 0—1 1 0 =
1 = Nothing
All LEDs on for 1 s
18 Not used
19 Modbus registers
reset unsigned int.
Resets Modbus Holding registers
to default values. When finished
this register is automatically reset
to ‘0’
0—1 0 0 =
1 = Idle
Reset Modbus registers
20 Modbus network
bus termination
resistor (NBT) unsigned int. Set device as ending the line or
not by connecting NBT 0—1 00 =
1 = NBT disconnected
NBT connected
Для получения дополнительной информации о протоколе обмена данных Modbus, посетите: http://www.modbus.org/docs/Modbus_over_serial_line_
V1_02.pdf
РЕГИСТРЫ ВВОДА (см. Таблица Входные регистры выше )
Регистры ввода используются только для чтения. Вся информация доступна
при помощи функции «Чтение значений из нескольких регистров ввода».
Таблица Регистры ввода показывают возвращаемый тип данных и способ их
интерпретации.
РЕГИСТРЫ ХРАНЕНИЯ( см. Таблица Регистры хранения выше )
Регистры хранения можно читать и записывать. Для этого доступные команды:
«Читай регистра хранения», «Запись отдельного регистра» и «Запиши
множество регистров». Регистры, которые не используются, доступны только
для чтения, и поэтому запись в этих регистрах не возвращает исключения
ошибки Modbus и не вносит никаких изменений.
УСТРОЙСТВО
СИГНАЛИЗАЦИИ
ALR -M1