Kollmorgen AKM1 Руководство пользователя

Тип
Руководство пользователя

Это руководство также подходит для

AKM
English Instructions Manual
Deutsch Betriebsanleitung
Italiano Manuale di Istruzioni
Español Manual de Instrucciones
Français Manuel d'Installation
Русский Руководство по эксплуатации
Edition June 2018
European Version (CE region)
English Deutsch Italiano Español Français Русский
Original Language is English. All other content is translated from the original language.
Keep all manualsas a product component during the life
span of the product. Pass all manualsto future users and
owners of the product.
Bewahren Sie alle Anleitungen während der gesamten Nutzungsdauer
des Produkts als Produktkomponente auf. Händigen Sie alle Anlei-
tungen künftigen Anwendern/Besitzern des Produkts aus.
Conserve el manual durante toda la vida útildel producto.
Entregue el manual a posteriores usuarios o propietarios del
producto.
Conservare il manuale per l’intera durata del prodotto. In caso di cam-
bio di proprietà ilmanuale deve essere fornito al nuovo utilizzatore
quale parte integrante del prodotto.
Сохраняйте все руководства как составную часть
продукта в течение всего срока его эксплуатации.
Передавайте руководство следующемупользователю
или владельцу продукта.
Le manuel faisant partie intégrante du produit, conservez-le pendant
toute la durée de vie du produit. Remettez le manuel au futur utilisateur
ou propriétaire du produit.
Record of Document Revisions
Revision Remarks
... Table with lifecycle information of this document ( # 209)
11/2017 Connector options G, H updated, Low Voltage windings added, corrected value B
10d
for AKM4
brake, note about B
10d
and number of springs, AKM82T resistance updated, Web pages updated
01/2018 Number of springs updated
06/2018 Thermal sensor KTY 83-110 replaced by PT1000, Pin-outs updated
Table of Contents
Instructions Manual
English
( # 3)
Technical Data ( # 167)
Betriebsanleitung
Deutsch
( # 29)
DimensionDrawings ( # 186)
Manuale di Istruzioni
Italiano
( # 55)
Connector Pinout ( # 200)
Manual de Instrucciones
Español
( # 83)
Approvals ( # 207)
Manuel d'Installation
Français
( # 111)
Руководство по эксплуатации
Русский
( # 139)
Trademarks
l EnDat is a registered trademark of Dr. Johannes Heidenhain GmbH
l HIPERFACE is a registered trademark of Max Stegmann GmbH
l HIPERFACE DSL® is registered trademark of SICK STEGMANN GmbH.
l DRIVE-CLiQ and SIMATIC are registered trademarks of SIEMENS Aktiengesellschaft
Technische Änderungen, die der Verbesserung der Geräte dienen, vorbehalten!
Gedruckt in der BRD. Alle Rechte vorbehalten. Kein Teil des Werkes darf in irgendeiner Form (Fotokopie, Mikrofilm
oder in einem anderen Verfahren) ohne schriftliche Genehmigung der Firma Kollmorgen Europe GmbH reproduziert
oder unter Verwendung elektronischer Systeme verarbeitet, vervielfältigt oder verbreitet werden.
Technical changes to improve the performance of the equipment may be made without prior notice!
Printed in the Federal Republic of Germany. All rights reserved. No part of this work may be reproduced in any form
(by photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means
without the written permission of Kollmorgen Europe GmbH.
Il produttore si riserva la facol di apportare modifiche tecniche volte al miglioramento degli apparecchi
Stampato nella Repubblica federale tedesca. Tutti i diritti riservati. Nessuna parte di questo documento può essere
rielaborata, riprodotta in qualsiasi forma (fotocopia, microfilm o altro processo) o diffusa mediante l'uso di sistemi
elettronici senza l'approvazione scritta della ditta Kollmorgen Europe GmbH o rielaborata, riprodotta o diffusa medi-
ante luso di sistemi elettronici.
Reservado el derecho de introducir modificaciones cnicas para la mejora de los equipos
Impreso en la RFA. Reservados todos los derechos. Prohibida la reproducción total o parcial de la presente obra por
cualquier medio (fotocopia, microfilm u otros), así como su procesamiento, reproducción y divulgación por medio de
sistemas electrónicos, sin expresa autorización escrita de la empresa Kollmorgen Europe GmbH.
Toutes modifications techniques concourant pour l'amélioration des appareils réservées !
Impri en Allemagne. Tous droits réservés. Aucune partie de l'ouvrage ne peut être reproduite sous quelque forme
que ce soit (imprie, photocopiée, microfile ou par un autre prodé) ou encore traitée, reproduite ou diffue
au moyen de systèmes électroniques sans autorisation écrite préalable de Kollmorgen Europe GmbH.
Сохраняется право вносить технические изменения, служащие для совершенствования устройств!
Напечатано в ФРГ. Все права защищены. Без письменного согласия фирмы Kollmorgen Europe GmbH
запрещается воспроизводить какие бы то ни было части данного руководства в любой форме печатной, в
виде фотокопии, микрофильма или другим способом), а также обрабатывать, размножать или распространять
их с использованием электронных систем.
2 Kollmorgen | kdn.kollmorgen.com | June 2018
1 English
1.1 General 4
1.1.1 About this manual 4
1.1.2 Abbreviations used 4
1.1.3 Symbols Used 4
1.2 Safety 5
1.2.1 You should pay attention to this 5
1.2.2 Use as directed 7
1.2.3 Prohibited use 7
1.2.4 Handling 8
1.3 Package 10
1.3.1 Delivery package 10
1.3.2 Nameplate 10
1.3.3 Model number description 11
1.4 Technical Description 15
1.4.1 General technical data 15
1.4.2 Style 15
1.4.3 Flange 15
1.4.4 Protection class 15
1.4.5 Insulation material class 16
1.4.6 Surface 16
1.4.7 Shaft end, A-side 16
1.4.8 Shaft seal 16
1.4.9 Protective device 16
1.4.10 Vibration class 17
1.4.11 Wiring technology 17
1.4.12 Holding brake 18
1.4.13 Fan for AKM7 18
1.4.14 Washdown and Washdown Food 19
1.5 Mechanical Installation 22
1.5.1 Important Notes 22
1.6 Electrical Installation 23
1.6.1 Important notes 23
1.6.2 Guide for electrical installation 24
1.6.3 Connection of the motors with preassembled cables 24
1.7 Setup 25
1.7.1 Important notes 25
1.7.2 Guide for setup 26
1.7.3 Trouble Shooting 27
1.8 Definition of Terms for Technical Data 28
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 3
AKM Installation | 1 English
1.1 General
1.1.1 About this manual
This manual describes the adjust in target series of synchronous servomotors (standard ver-
sion). The motors are operated in drive systems together with Kollmorgen servo amplifiers.
Please observe the entire system documentation, consisting of:
l Instructions manual for the servo amplifier
l Manual Bus Communication (e.g. CANopen or EtherCAT)
l Online help of the amplifier's setup software
l Regional accessories manual
l Technical description of the AKM series of motors
More background information can be found on the Kollmorgen Developer Network, available
at kdn.kollmorgen.com.
1.1.2 Abbreviations used
Abbreviations used for technical data see chapter "Definition of terms" ( # 28).
In this document, the symbolism ( # 53) means: see page 53.
1.1.3 Symbols Used
Symbol Indication
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
Indicates situations which, if not avoided, could result in
property damage.
This symbol indicates important notes.
Warning of a danger (general). The type of danger is specified
by the text next to the symbol.
Warning of danger from electricity and its effects.
Warning of danger from hot surface.
Warning of suspended loads.
4 Kollmorgen | kdn.kollmorgen.com | June 2018
1.2 Safety
This section helps you to recognize and avoid dangers to people and objects.
1.2.1 You should pay attention to this
Specialist staff required!
Only properly qualified personnel are permitted to perform such tasks as transport,
assembly, setup and maintenance. Qualified specialist staff are persons who are familiar
with the transport, installation, assembly, commissioning and operation of motors and who
bring their relevant minimum qualifications to bear on their duties:
l Transport: only by personnel with knowledge of handling electrostatically sensitive com-
ponents.
l Mechanical Installation: only by mechanically qualified personnel.
l Electrical Installation: only by electrically qualified personnel.
l Setup: only by qualified personnel with extensive knowledge of electrical engineering and
drive technology
The qualified personnel must know and observe IEC 60364 / IEC 60664 and national acci-
dent prevention regulations.
Read the documentation!
Read the available documentation before installation and commissioning. Improper handling
of the motor can cause harm to people or damage to property. The operator must therefore
ensure that all persons entrusted to work on the motor have read and understood the manual
and that the safety notices in this manual are observed.
Pay attention to the technical data!
Adhere to the technical data and the specifications on connection conditions (rating plate and
documentation). If permissible voltage values or current values are exceeded, the motors
can be damaged, for example by overheating.
Perform a risk assessment!
The manufacturer of the machine must generate a risk assessment for the machine, and take
appropriate measures to ensure that unforeseen movements cannot cause injury or damage
to any person or property. Additional requirements on specialist staff may also result from the
risk assessment.
Transport safely!
Lift and move motors with more than 20 kg weight (AKM7 and AKM8) only with lifting tools.
Lifting unassisted could result in back injury. Always observe the hints on ( # 8)
Secure the key!
Remove any fitted key (if present) from the shaft before letting the motor run without coupled
load, to avoid the dangerous results of the key being thrown out by centrifugal forces. When
delivered, the key is protected with a plastic cap.
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 5
AKM Installation | 1 English
Hot surface!
The surfaces of the motors can be very hot in operation, according to their protection cat-
egory. Risk of minor burns! The surface temperature can exceed 100°C. Measure the tem-
perature, and wait until the motor has cooled down below 40°C before touching it.
Earthing! High voltages!
It is vital that you ensure that the motor housing is safely earthed to the PE (protective earth)
busbar in the switch cabinet. Risk of electric shock. Without low-resistance earthing no per-
sonal protection can be guaranteed and there is a risk of death from electric shock.
Not having optical displays does not guarantee an absence of voltage. Power connections
may carry voltage even if the motor shaft is not rotating.
Do not unplug any connectors during operation. There is a risk of death or severe injury from
touching exposed contacts. Power connections may be live even when the motor shaft is not
rotating. This can cause flashovers with resulting injuries to persons and damage to the con-
tacts.
After disconnecting the servo amplifier from the supply voltage, wait several minutes before
touching any components which are normally live (e.g. contacts, screw connections) or open-
ing any connections.
The capacitors in the servo amplifier can still carry a dangerous voltage several minutes after
switching off the supply voltages. To be quite safe, measure the DC-link voltage and wait
until the voltage has fallen below 60 V.
Secure hanging loads!
Built-in holding brakes do not ensure functional safety!
Hanging loads (vertical axes) require an additional, external mechanical brake to ensure per-
sonnel safety.
6 Kollmorgen | kdn.kollmorgen.com | June 2018
1.2.2 Use as directed
l The AKM series of synchronous servomotors is designed especially for drives for industrial
robots, machine tools, textile and packing machinery and similar with high requirements for
dynamics.
l The user is only permitted to operate the motors under the ambient conditions which are
defined in this documentation.
l The use of Washdown motors is allowed in environments with caustic acids and bases with
respect to the defined conditions on page ( # 19).
l The use of Washdown Food motors is allowed in applications with indirect contact to food
and beverage.
l The AKM series of motors is exclusively intended to be driven by servo amplifiers under
speed and / or torque control.
l The motors are installed as components in electrical apparatus or machines and can only be
commissioned and put into operation as integral components of such apparatus or machines.
l The thermal sensor which is integrated in the motor windings must be observed and eval-
uated.
l The holding brakes are designed as standstill brakes and are not suited for repeated oper-
ational braking.
l The conformity of the servo system to the standards mentioned in the CE Declaration of
Conformity ( # 207) is only guaranteed when the components (servo amplifier, motor,
cables etc.) that are used have been supplied by Kollmorgen.
1.2.3 Prohibited use
l The use of the Standard Motors is prohibited
o
directly on mains supply networks,
o
in areas where there is a risk of explosions,
o
in contact with food and beverage,
o
in environments with caustic and/or electrically conducting acids, bases, oils, vapors,
dusts.
l The use of the Washdown Motors is prohibited
o
directly on mains supply networks,
o
in areas where there is a risk of explosions,
o
in contact with food and beverage,
o
in environments with acids or bases with pH value below 2 or above 12,
o
in environments with acids or bases that have not been tested by Kollmorgen.
l The use of the Washdown Food Motors is prohibited
o
directly on mains supply networks,
o
in areas where there is a risk of explosions,
o
in direct contact with food and beverage.
l Commissioning the motor is prohibited if the machine in which it was installed
o
does not meet the requirements of the EC Machinery Directive,
o
does not comply with the EMC Directive,
o
does not comply with the Low Voltage Directive.
l Built-in holding brakes without further equipment must not be used to ensure functional
safety.
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 7
AKM Installation | 1 English
1.2.4 Handling
1.2.4.1 Transport
l Climate category 2K3 according to IEC 60721-3-2, EN61800-2
l Temperature: -25...+70°C, max. 20K/hr change
l Humidity: rel. humidity 5% - 95% , no condensation
l Only by qualified personnel in the manufacturer’s original recyclable packaging
l Avoid shocks, especially to the shaft end
l If the packaging is damaged, check the motor for visible damage. Inform the car rier and, if
appropriate, the manufacturer.
Transport of motors with a weight of more than 20kg
Lifting eyes must be used to safely transport AKM7 and AKM8 motors (> 20kg). Observe any
transport instructions included in the packaging of the motor.
We recommend the transport tool ZPZM 120/292 for moving the motors.
Suspension Unit ZPMZ 120/292 consists of a beam, suspended to the crane hook and two
double-run chain suspenders.
DANGER
Suspended load. Risk of death if load falls. Never step under the load,
while the motor is raised.
l The fastening screws of the lifting eyes must be fully screwed in.
l The lifting eyes must be positioned on the supporting surface in an even and flat manner.
l Prior to use, check the lifting eyes for secure fitting and any obvious damages (corrosion,
deformation).
l Lifting eyes with deformations must not continue to be used.
8 Kollmorgen | kdn.kollmorgen.com | June 2018
1.2.4.2 Packaging
l Cardboard packing with Instapak® foam cushion.
l You can return the plastic portion to the supplier (see "Disposal").
Motor
type
Packing Max. stacking
height
Motor
type
Packing Max. stacking
height
AKM1 Cardboard 10 AKM5 Cardboard 5
AKM2 Cardboard 10 AKM6 Cardboard 1
AKM3 Cardboard 6 AKM7 Cardboard 1
AKM4 Cardboard 6 AKM8 Pallet 1
1.2.4.3 Storage
l Climate category 1K4 according to IEC 60721-3-1, EN61800-2
l Storage temperature: - 25...+55°C, max. variation 20K/hr.
l Humidity: rel. humidity 5% - 95%, no condensation
l Store only in the manufacturer’s original recyclable packaging
l Max. stacking height: see table in chapter "Packaging"
l Storage time: unlimited
1.2.4.4 Maintenance / Cleaning
l Maintenance and cleaning only by qualified personnel
l The ball bearings should be replaced after 20,000 hours of operation under rated conditions
(by the manufacturer).
l Check the motor for bearing noise every 2500 operating hours, respectively each year. If any
noises are heard, stop the operation of the motor, the bearings must be replaced (by the man-
ufacturer).
l Opening the motor invalidates the warranty.
l If the housing is dirty, clean housing with Isopropanol or similar, do not immerse or spray
1.2.4.5 Repair / Disposal
Repair of the motor must be done by the manufacturer. Opening the motor invalidates the war-
ranty. In accordance to the WEEE-2002/96/EG-Guidelines we take old devices and
accessories back for professional disposal, if the transport costs are taken over by the
sender. Send the motor to:
KOLLMORGEN Europe GmbH
Pempelfurtstr. 1
D-40880 Ratingen
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 9
AKM Installation | 1 English
1.3 Package
1.3.1 Delivery package
l Motor from the AKM series
l Product manual (multi language) printed, one per delivery
1.3.2 Nameplate
With standard motors the nameplate is adhesive on the housing side. With washdown
motors the nameplate is engraved on the housing side, an additional nameplate is added to
every motor package.
Legend Description
MODEL motor type
CUST P/N customer part no.
Ics I0rms (standstill current)
Tcs M0 (standstill torque)
Vs Un (DC bus link voltage)
Nrtd nn (rated speed @ Un)
Prtd Pn (rated power)
Year of manufacturing is coded in the serial number: the first two digits of the serial number
are the year of manufacturing, e.g. "17" means 2017.
10 Kollmorgen | kdn.kollmorgen.com | June 2018
1.3.3 Model number description
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 11
AKM Installation | 1 English
1.3.3.1 Connector Options (C)
Pinout for the connector options are listed in chapter "Connector Pinout" from ( # 200).
Technical description of used connectors see KDN (Mating Connectors).
Connector Description
Contacts -
Pins
max. Current
[A]
max. Cross
Section [mm²]
Protection
Class
Suggested mating
connector
Connector Usage* Power/Signal Power/Signal Power/Signal
M23
SpeedTec
Ready
(Size 1)
Power & Brake 4 / 4 30 / 10 4 / 1.5 IP65 BSTA-108-NN-00-08-0036
Feedback - / 12 - / 10 - / 0.5 IP65 ASTA-021-NN-00-10-0035
Feedback - / 17 - / 9 - / 0.5 IP65 ASTA-035-NN-00-10-0035
Hybrid* 4 / 4 30 / 10 4 / 1.5 IP65 BSTA-108-NN-00-08-0036
M40 (Size
1.5)
Power & Brake 4 / 2 75 / 30 16 / 4 IP65 CSTA-263-NN-00-26-0001
M12 DRIVE-CLiQ - / 8 - / 2 - / 0.5 IP65
Standard Siemens
Drive-Cliq cable
M23-6 DRIVE-CLiQ 6 / - 30 / - 4 / - IP65
i-tec Hybrid* 4 / 5 14 / 3.6 1.5 / 0.75 IP65
ESTB-202-NN-00-1110-
0500
y-tec
Power & Brake 4 / 5 14 / 3.6 1.5 / 0.75 IP65 ESTB-202-NN-00-31-0500
Feedback - / 12 - / 5 - / 0.75 IP65 ESTB-002-NN-00-31-0001
Feedback - / 15 - / 5 - / 0.75 IP65 ESTB-205-NN-00-31-0002
Terminal
box
Power & Brake 4 / 2 150 / 15 25 / 2.5 IP65 -
* Hybrid means: Power and Feedback (plus Brake) on the same connector and in one cable
Reference Connector-Motor
PTC*
KTY 84-
130*
PT1000* Connection Usable with
Position of con-
nection
B 1 3 2 SpeedTec Ready connectors AKM2
Angular, rotatable,
motor mounted
C 7 4 2 SpeedTec Ready connectors AKM1-AKM2 0.5m cable mounted
C 1 4 2 SpeedTec Ready connectors AKM3-AKM7 (≤ 23,5A)
Angular, rotatable,
motor mounted
D** - 9 1 i-tec Hybrid connector AKM1 Motor mounted
D** - 9
1 Hybrid connector SpeedTec
Ready
AKM2-AKM6
Angular, rotatable,
motor mounted
G - V 2 SpeedTec Ready connectors AKM2-AKM7 (≤ 23,5A)
Straight, motor moun-
ted
H - W
1 power connector M40, 1 Feed-
back connector SpeedTec Ready
AKM7xQ & AKM82T
Angular, rotatable,
motor mounted
- R** -
1 power connector M23-6,
1 Feedback connector M12
AKM4-AKM7 (≤23,5A)
Motor mounted.
M23-6 angular, rotat-
able.
M12 Straight.
T 2 X
1 Terminal box, 1 Feedback con-
nector SpeedTec Ready
AKM8 Motor mounted
- U** -
1 power connector M23-6,
1 Feedback connector M12
AKM4-AKM7 (≤23,5A)
Straight, motor moun-
ted
Y 1 Z 1 y-tec connector AKM1 Motor mounted
* Temperature sensor PTC or KTY or PT1000( # 16)
** With connector options D, R, and U the temperature sensor type depends on the feedback, see ( # 14)
12 Kollmorgen | kdn.kollmorgen.com | June 2018
1.3.3.2 Feedback Options (CA)
Motor length depends on the built-in feedback device, see dimension diagrams from ( #
186).
Retrofitting is not possible. Pinout for the connector options are listed ( # 200).
Technical description of the feedback systems see Kollmorgen Developer Network
(MultiFeedback).
Feedback Description
Code Description Type Remarks
Lines per
rev.
# of
revs.
usable
with drives
1- Comcoder EPC 15T Single turn, optical 1024 1 All
2- Comcoder EPC 15T Single turn, optical 2048 1 All
AA BiSS B Encoder AD34/AD58 Single turn, optical 2048 1 All
AB BiSS B Encoder AD34/AD58 Multi turn, optical 2048 4096 All
C- SFD Size 10/15/21 Single turn, inductive, 4 lines 11bit 1 AKD
CA SFD3 Size 10/15/21 Single turn, inductive, 2 lines 11bit 1 AKD,S700
DA EnDAT 2.1 Encoder ECN1113/1313 Single turn, optical 512/2048* 1 All
DB EnDAT 2.1 Encoder EQN1125/1325 Multi turn, optical 512/2048* 4096 All
LA EnDAT 2.1 Encoder ECI1118/1319 Single turn, inductive 16/32** 1 All
LB EnDAT 2.1 Encoder EQI1130/1331 Multi turn, inductive 16/32** 4096 All
MA DRIVE-CLiQ Encoder ECN1324S Safety Single turn, optical 24bit 1 Siemens****
MB DRIVE-CLiQ Encoder EQN1336S Safety Multi turn, optical 24bit 4096 Siemens****
GA HIPERFACE Encoder SKS36 Single turn, optical 128 1 Sx
GB HIPERFACE Encoder SKM36 Multi turn, optical 128 4096 Sx
GC HIPERFACE Encoder SEK34 Single turn, capacitive 16 1 Sx
GD HIPERFACE Encoder SEL34 Multi turn, capacitive 16 4096 Sx
GE HIPERFACE DSL Encoder EKS36 Single turn, optical, 18bit 1 AKD,S700
GF HIPERFACE DSL Encoder EKM36 Multi turn, optical,
18bit +
12bit
4096 AKD,S700
GJ HIPERFACE Encoder SKS36 Single turn, optical 128 1 AKD
GK HIPERFACE Encoder SKM36 Multi turn, optical 128 4096 AKD
GM Safe HIPERFACE Encoder SKS36S
Safety, like GJ, SIL2, PLd,
Cat.3
128*** 1 AKD
GN Safe HIPERFACE Encoder SKM36S
Safety, like GK, SIL2, PLd,
Cat.3
128*** 4096 AKD
GP HIPERFACE Encoder SEK34 Single turn, capacitive 16 1 AKD
GR HIPERFACE Encoder SEL34 Multi turn, capacitive 16 4096 AKD
R- Resolver Size 10/15/21 Single turn, inductive 2 poles 1
All except
AKD-N
* x/y data for AKM2-4/AKM5-8
** x/y data for AKM2-3/AKM4-8
*** Certificates for safety feedbacks: see Kollmorgen Developer Network (Approvals) or Kollmorgen website.
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 13
AKM Installation | 1 English
Reference Feedback-Motor
Connector code (PTC/KTY
84-130/PT1000)
B/1/3 C/1/4 C/7/4 (Kabel) D/-/9 G/-/V H/-/W -/R/- T/2/X -/U/- Y/1/Z
Code Feedback Usable with AKM...
1- Comcoder 2 3-7 1-2 - 2-6 7,82T - 8 - 1
2- Comcoder 2 3-7 1-2 - 2-6 7,82T - 8 - 1
AA BiSS B 2 3-7 2 - 2-6 7,82T - 8 - -
AB BiSS B 2 3-7 2 - 2-6 7,82T - 8 - -
C- SFD* 2 3-7 1-2 1-6 (PTC) 2-6 7,82T - 8 - 1
CA SFD3 - - - 1-6 (PT1000) - - - - - -
DA EnDAT 2.1 2 3-7 2 - 2-6 7,82T - 8 - -
DB EnDAT 2.1 2 3-7 2 - 2-6 7,82T - 8 - -
LA EnDAT 2.1 2 3-7 2 - 2-6 7,82T - 8 - -
LB EnDAT 2.1 2 3-7 2 - 2-6 7,82T - 8 - -
MA DRIVE-CLiQ** - - - - - - 4-7 - 4-7 -
MB DRIVE-CLiQ** - - - - - - 4-7 - 4-7 -
GA Hiperface 2 3-7 2 - 2-6 7,82T - 8 - -
GB Hiperface 2 3-7 2 - 2-6 7,82T - 8 - -
GC Hiperface - - 1 - - - - - - 1
GD Hiperface - - 1 - - - - - - 1
GE Hiperface DSL - - - 2-6 (PT1000) - - - - - -
GF Hiperface DSL - - - 2-6 (PT1000) - - - - - -
GJ Hiperface 2 3-7 2 - 2-6 7,82T - 8 - -
GK Hiperface 2 3-7 2 - 2-6 7,82T - 8 - -
GM Safe Hiperface*** 2 3-7 2 - 2-6 7,82T - 8 - -
GN Safe Hiperface*** 2 3-7 2 - 2-6 7,82T - 8 - -
GP Hiperface - - 1 - - - - - - 1
GR Hiperface - - 1 - - - - - - 1
R- Resolver 2 3-7 1-2 - 2-6 7,82T - 8 - 1
* no brake
** temperature sensor according to current Siemens requirements. For more information contact Kollmorgen.
*** with PTC temperature sensor only
14 Kollmorgen | kdn.kollmorgen.com | June 2018
1.4 Technical Description
1.4.1 General technical data
Ambient temperature
(at rated values)
5...+40°C for site altitude up to 1000m amsl
It is vital to consult our applications department for ambient tem-
peratures above 40°C and encapsulated mounting of the
motors.
Permissible humidity
(at rated values)
95% rel. humidity, no condensation
Power derating
(currents and torques)
1%/K in range 4C...50°C up to 1000m amsl
for site altitude above 1000m amsl and 4C
6% up to 2000m amsl
17% up to 3000m amsl
30% up to 4000m amsl
55% up to 5000m amsl
No derating for site altitudes above 1000m amsl with tem-
perature reduction of 10K / 1000m
Ball-bearing life 20.000 operating hours
Technical data for every motor type can be found in chapter "Technical Data" from ( #
167).
1.4.2 Style
The basic style for the AKM
motors is style IM B5 accord-
ing to EN 60034-7.
1.4.3 Flange
IEC flange accuracy according to DIN 42955. Tolerances of shaft extension run-out and of
mounting flanges for rotating electrical machines.
Code Flange
A IEC with accuracy N, fit AKM1: h7, fit AKM2-8: j6
R IEC with accuracy R, fit AKM1: h7, fit AKM2-8: j6
M IEC with accuracy N, fit j6, reinforced bearing, AKM8 only
W IEC, fit j6,special flange coating for Washdown or Washdown Food motors
B NEMA, dimensions see AKM Selection Guide (Kollmorgen website, US-English)
1.4.4 Protection class
Standard Motor Connector Option Shaft Seal Protection class
AKM1 C, D without IP40
AKM1 C, D, Y with IP65
AKM2-AKM7 B, C, D, G, H, T without IP54
AKM8 H, T without IP52
AKM2-AKM8 B, C, D, G, H, T with IP65
AKM2-AKM6 Washdown B, C, D, G with IP67
AKM2-AKM6 Washdown Food B, C, D, G with IP67
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 15
AKM Installation | 1 English
1.4.5 Insulation material class
The motors come up to insulation material class F according to IEC 60085 (UL1446 class F).
1.4.6 Surface
The motors are coated with polyester powder coating in matte black. This finish is not res-
istant against solvents (e.g. trichlorethylene, nitro-thinners, or similar).
1.4.7 Shaft end, A-side
Power transmission is made through the cylindrical shaft end A, fit k6 (AKM1: h7) to
EN50347, with a locking thread but without a fitted keyway.
Motors are also available with keyway and inserted key according to DIN 6885. The shaft
with keyway is balanced with short (half) key.
Bearing life is calculated with 20.000 operating hours.
Order code Shaft end Available for
N Smooth shaft all types, standard
C Keyway, closed AKM 2...8
K Keyway, open AKM 1...8
Radial force
If the motors drive via pinions or toothed belts, then high radial forces will occur. The per-
missible values at the end of the shaft may be read from the diagrams in chapter "Drawings"
from ( # 186). The maximum values at rated speed you will find at the technical data from
( # 167). Power take-off from the middle of the free end of the shaft allows a 10% increase
in F
R
.
Axial force
When assembling pinions or wheels to the axis and use of e.g. angular gearheads axial
forces arise. The maximum values at rated speed are found in the technical data.
Coupling
Double-coned collets have proved to be ideal zero-backlash coupling devices, combined, if
required, with metal bellows couplings.
1.4.8 Shaft seal
If AKM is connected to a machine flange with unsealed shaft region, then the shaft seal
(option "01") ensures the shaft sealing.
l The Teflon shaft seal ensures the IP67 protection for the shaft area.
l The rated performance is achieved after some hours of shaft seal run-in. No special pro-
cedure for run-in is needed.
l Some shedding of Teflon material is normal and does not affect the function.
l Shaft seal operation in dry-running mode is prohibited. Contact Kollmorgen for special shaft
seal solution in case the dry-running operation is required.
l Shaft seal is pre-lubricated by FDA grease.
1.4.9 Protective device
The standard version of each motor is fitted with an electrically isolated PTC (rated
temperature 15C ± 5%). The PTC does not provide any protection against short, heavy
overloading.
The motor can be delivered with a PT1000 or KTY 84-130 sensors optionally (see Connector
Options 1, 2, 7 and D on ( # 200)( # 12).
16 Kollmorgen | kdn.kollmorgen.com | June 2018
With digital feedback system SFD, SFD3, DSL (C-, CA, GE, GF) the temperature sensor
status is transmitted digitally and evaluated in the drive.
Provided that our configured feedback cables are used, the sensor is integrated into the mon-
itoring system of the digital servo amplifiers.
1.4.10 Vibration class
The motors are made to vibration class A according to EN60034-14. For a speed range of
600-3600rpm and a shaft center between 56-132mm, this means that the actual value of the
permitted vibration severity is 1.6mm/s.
Velocity [rpm] max. rel. Vibration Displacement [µm] max. Run-out [µm]
<= 1800 90 23
> 1800 65 16
1.4.11 Wiring technology
1.4.11.1 Connectors
Descriptions of the available connectors: ( # 12). Connector pinout: from ( # 200).
1.4.11.2 Wire cross sections
Power Cable, Combi Cable
Combi cables contain 4 power lines and 2 additional lines for motor holding brake control.
Cross Section Current Carrying
Capacity
Remarks
Cable Combi Cable
(4x1) (4x1+(2x0.75)) 0A < I0rms 10.1A The brackets (...) show the
shielding.
Current carrying capacity
acc. to EN60204-1:2006
Table 6, Column B2
(4x1.5) (4x1.5+(2x0.75)) 10.1A < I0rms 13.1A
(4x2.5) (4x2.5+(2x1)) 13.1A < I0rms 17.4A
(4x4) (4x4+(2x1)) 17.4A < I0rms 23A
(4x6) (4x6+(2x1)) 23A < I0rms 30A
(4x10) (4x10+(2x1.5)) 30A < I0rms 40A
(4x16) (4x16+(2x1.5)) 40A < I0rms 54A
(4x25) (4x25+(2x1.5)) 54A < I0rms 70A
Feedback Cable
Type Cross Section Remarks
Resolver, SFD (4x2x0.25)
Encoder (7x2x0.25) BiSS, EnDAT, HIPERFACE
Comcoder (8x2x0.25) Incremental Encoder + Hall
Hybrid Cable
Type Cross Section Remarks
SFD (4x1.0+2x(2x0.75)) 4 power lines & 4 signal lines for SFD
respectivelySFD (4x1.5+2x(2x0.75))
SFD3/DSL (4x1.0+(2x0.34)+(2x0.75)) 4 power lines & 2 brake lines &
2 signal lines for SFD3/DSLSFD3/DSL (4x1.5+(2x0.34)+(2x0.75))
SFD3/DSL (4x2.5+(2x0.34)+(2x1.0))
SFD3/DSL (4x4+(2x0.34)+(2x1.0))
Technical description of Hybrid Cable see KDN (Hybrid Cables).
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 17
AKM Installation | 1 English
1.4.12 Holding brake
All motors are optionally available with a holding brake. A spring applied brake (24V DC) is
integrated into the motors. When this brake is de-energized it blocks the rotor.
WARNING
If there is a suspended load (vertical axes), the motor's holding brake is
released, and, at the same time, the servo drive does not produce any out-
put, the load may fall down! Risk of injury for the personnel operating the
machine. Functional safety in case of hanging loads (vertical axes) can
be ensured only by using an additional, external, mechanical brake.
The holding brakes are designed as standstill brakes and are not suited for repeated oper-
ational braking. In the case of frequent, operational braking, premature wear and failure of the
holding brake is to be expected.
The motor length increases when a holding brake is mounted.
The holding brake can be controlled directly by the servo amplifier (no personal safety !), the
winding is suppressed in the servo amplifier additional circuitry is not required (see instruc-
tion manual of the servo amplifier). If the holding brake is not controlled directly by the servo
drive, an additional wiring (e.g. varistor) is required. Consult our support department.
Brake data are listed in chapter "Technical Data Brakes" from ( # 184) .
1.4.13 Fan for AKM7
For the AKM7 model size, an add-on kit for forced ventilation is available. The integrated fan
enables up to 30% more power output for the AKM7 motors. Assembly instructions for the
fan kit is contained within the scope of delivery of the add-on kit.
The fan housing can be mounted either with both the supplied
brackets and spacers or with the brackets only. The choice of
mounting method depends on the application. If strong vibra-
tions are expected, you should use both brackets and
spacers. Motors with integrated brakes require the longs
spacers.
Make sure, that free air flow is available for the fan. Keep a space of at least 25 mm behind
the fan guard.
The motors become dirty considerably faster due to forced convection. Dirt deposits lead to
falling cooling capacity and can put the motors at risk. Dust may burn in case of over-
heating.So clean the air duct, the fan, and the motor at regular intervals.
By adding a fan, the mounting dimensions of AKM7 motors increase.
In case of AKM7 motors with connector option "C", winding "Q" and forced ventilation you
must limit the motor current to 23,5A for connector protection.
You can find technical information on AKM7 motors with fans ( # 181).
You can find the dimensional drawing for AKM7 motors with fans on ( # 195).
18 Kollmorgen | kdn.kollmorgen.com | June 2018
1.4.14 Washdown and Washdown Food
These motor variants are used in applications that are subject to strict hygiene regulations in
which it is essential that the formation of nucleation and corrosion are avoided and in which
machines must be cleaned cyclically.
The motors are based on the standard types AKM2 - AKM6 with special modifications for use
in the food-processing industry or even in the packaging industry. In addition, it is also pos-
sible to coat the flange in each case but then it is not possible to assure tolerance class N
for the flange.
In the type code, the coating of the motor housing (type W for Washdown, "F" for Wash-
down Food) is defined separately in the version (last two digits) and the flange coating.
Washdown/Washdown
Food Motor
Connector
Options
Suggested mating connector Flange
Options
AKM2 B*, D*, G
Option B, C, D, G (Hummel M23 INOX con-
nectors):
Power & Brake:
7084943102
Feedback 12-pin:
7004912102
Feedback 18-pin:
7003917102
A, B, W, R
AKM3, 4, 6 C*, D*, G A, B, W, R
AKM5 C*, D*, G B, C, W
* Do not turn the connector on the motor more than +/- 180 °, greater rotation angle will dam-
age the internal connections.
1.4.14.1 Washdown
AKM^^^-^^^^^-^W
AKM^^^-W^^^^^-^W
Washdown without flange coating
Washdown with flange coating of IEC A flange
The Washdown motors must not come into contact with any unpacked foodstuffs.
Application Area: Harsh environments, outdoors
Example: Transport in the foodstuff and packing area without contact with
foodstuff, radar stations, wind turbines, offshore installations
Standards: UL, CE, RoHS
Surface: Silver coating
Immunity: Against tested industrial cleaning agent ( # 20), corrosion-proof
Degree of protection: IP67
Shaft: Stainless steel
Rotary shaft seal: PTFE
Lubricant: Industrial bearing grease, non-food-grade
Connector: Stainless steel, smooth surface
Screws: Stainless Steel
Name plate: Engraved, additional nameplate in the package
Size: AKM2 - AKM6
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018 19
AKM Installation | 1 English
1.4.14.2 Washdown Food
AKM^^^-^^^^^-^F
AKM^^^-W^^^^^-^F
Washdown Food without flange coating
Washdown Food with flange coating of IEC A flange
The surface of the Washdown food motor has passed all tests as per FDA GlobalMigration
for indirect contact with foodstuffs. Any direct contact with unpacked foodstuffs is not per-
mitted.
Application Area: Foodstuffs and drinks industry, no direct contact with unpacked
foodstuff
Example: Cutting, packing and filling without direct contact with foodstuffs.
Motor laterally or below the food.
Standards: UL, CE, RoHS, FDA
Surface: White coating
Immunity: Against tested industrial cleaning agent ( # 20), corrosion-proof
Global Migration: US FDA Regulations 21 CFR 175.300, Condition of Use E
Degree of protection: IP67
Shaft: Stainless steel
Rotary shaft seal: PTFE as per FDA
Lubricant: food-grade as per FDA
Connector: Stainless steel, smooth surface
Screws: Stainless Steel
Name plate: Engraved, additional nameplate in the package
Size: AKM2 - AKM6
1.4.14.3 Tested and confirmed properties with respect to cleaning agents
The testing lab of ECOLAB Deutschland GmbH tested the resistance of the Washdown and
Washdown Food surfaces to the following industrial cleaning agents:
l P3-topactive DES
l P3-topactive LA
l P3-topax 56
l P3-topax 66
l P3-topax 91
In the process, the surfaces were immersed in the respective cleaning agent at room tem-
perature for 28 days. This corresponds to approx. 2,500 cleaning cycles with 15-minute con-
tact each with the cleaning agent or 1,500 cleaning cycles with cleaning and subsequent
disinfection.
The certificates are located in our Kollmorgen Developer Network on the Approvals page.
Kollmorgen can only give a guarantee for the motor's lifecycle if the tested cleansing agents
are used. Any cleansing agent other than those mentioned above can be tested by Koll-
morgen upon request and, if appropriate, be approved.
20 Kollmorgen | kdn.kollmorgen.com | June 2018
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212

Kollmorgen AKM1 Руководство пользователя

Тип
Руководство пользователя
Это руководство также подходит для

Задайте вопрос, и я найду ответ в документе

Поиск информации в документе стал проще с помощью ИИ