Mitsubishi Electric AL2-2TC-ADP Инструкция по установке

Тип
Инструкция по установке
JY997D09501H
AL2-2TC-ADP
Installation Manual Installationsanleitung
Manuel d’installation Manuale di installazione
Manual de Instalación Installationshandbok
Руководство по установке
JY997D09501H
Caution
Persons trained in the local and national electrical standards must perform all
tasks associated with wiring the
α2 Series Controller and AL2-2TC-ADP.
Please use an isolated Power supply and turn off the Power before any wiring
operation is performed.
Input and Output cables should not be run through the same multicore cable or
share the same wire.
Input cable (from sensor to AL2-2TC-ADP) must be less than 10m (32’81’’)
and the output cable length must be less than 3m (9' 10").
The wire should be used as a single cable or the multicore wires (can be used
with a crimp terminal) should be carefully twisted together.
Do not connect a soldered wire end to the AL2-2TC-ADP.
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Do not install in areas with: excessive or conductive dust, corrosive or
flammable gas, moisture or rain, excessive heat, regular impact shocks or
excessive vibration.
The connectors must be covered to prevent contact with “Live” wires.
The
α2 Series Controller and AL2-2TC-ADP must be installed in a distribution
box or a control cabinet. The distribution box should be equipped with a cover
for the AL2-2TC-ADP module to avoid any possible foreign objects from falling
inside
Leave a minimum of 10mm (0.40") of space for ventilation between the top and
bottom edges of the AL2-2TC-ADP and the enclosure walls.
The
α2 Series is not designed to be used in life critical or fail safe applications.
Under no circumstances will Mitsubishi Electric be liable or responsible for any
consequential damage that may arise as a result of the installation or use of
this equipment.
Please read the
α2 Series Hardware and α2 Series Programming Manuals
for further information.
The AL2-2TC-ADP should be adjusted for offset and gain purposes, therefore,
turn off the Power before performing the adjustment wiring. Please refer to the
α2 Hardware manual for further details concerning offset and gain adjustment.
The maximum distance between the
α2 Series Controller and the AL2-2TC-
ADP should be 3m (9' 10") or less.
The power cable should be less than 10 m (32' 81") in length.
A sensor with insulation rated for 500 V or more should be used when the
sensor is placed near a conductive material.
Achtung
Nur speziell ausgebildetes Personal darf die elektrische Verdrahtung der
Geräte vornehmen. Sollten Sie spezialisierte Unterstützung brauchen, wenden
Sie sich an eine anerkannt ausgebildete Elektrofachkraft, die mit den lokalen
und nationalen Sicherheitsstandards der Automatisierungstechnik vertraut ist.
Verwenden Sie ein isoliertes Netzgerät, und schalten Sie vor allen
Verdrahtungsarbeiten die Spannung ab.
Die Ein- und Ausgangskabel dürfen nicht durch das gleiche Multikernkabel
oder den gleichen Kabelbaum verlegt werden.
Die Länge der Leitungen für Eingangssignale (vom Sensor zum AL2-2TC-
ADP) darf 10 m und die der Leitungen für Ausgangssignale darf 3 m nicht
überschreiten.
Verwenden Sie zum Anschluss Leitungen mit starren oder flexiblen Drähten
(für Crimp-Anschluss), die sorgfältig verdrillt sind.
Verwenden Sie keine flexible Drähte mit verlötetem Ende an einem AL2-2TC-
ADP.
Um eine Beschädigung der Kabel zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Die Geräte dürfen den folgenden Umgebungsbedingungen nicht ausgesetzt
werden: Umgebungen mit einem hohen Grad an leitfähigen Stäuben,
Korrosion, entzündbaren Gasen, Nebel, Regen, direkte Sonnenbestrahlung,
große Hitze, starke Schockwellen und Vibrationen.
Die Anschlüsse müssen abgedeckt werden, um Stromberührung zu
vermeiden.
•Die
α2-Steuerung und das AL2-2TC-ADP müssen in einen Schaltschrank
nach DIN 43880 oder einen Steuerkasten eingebaut werden. Das AL2-2TC-
ADP muss durch eine Abdeckung vor dem Eindringen von Fremdkörpern
geschützt werden.
Zur Kühlung muss zwischen der oberen und unteren Seite des AL2-2TC-ADP
und anderen Geräten ein Abstand von 10 mm eingehalten werden.
ENG
GER
•Die α2-Steuerung wurde nicht für lebenserhaltende oder selbstüberwachende
Anwendungen entwickelt.
MITSUBISHI ELECTRIC übernimmt unter keinen Umständen die Haftung oder
Verantwortung für einen Schaden, der aus einer unsachgemäßen Installation oder
Anwendung der Geräte oder des Zubehörs entstanden ist.
Weitere Informationen entnehmen Sie bitte der Hardware- und der
Programmieranleitung zur
α2-Steuerung.
Vor der Einstellung von Offset und Verstärkung am AL2-2TC-ADP muss die
Versorgungspannung ausgeschaltet werden. Nähere Hinweise zur Offset- und
Verstärkungseinstellung finden Sie in der Hardware-Beschreibung zur
α2-
Steuerung.
Die Leitung zwischen der
α2-Steuerung und dem AL2-2TC-ADP darf max. 3 m lang
sein.
Die Länge der Stromversorgungsleitungen darf 10 m nicht überschreiten.
Wird der Sensor in der Nähe von leitfähigen Material platziert, muss ein Sensor mit
einer Isolierung für min. 500 V verwendet werden.
Attention
Toutes les opérations liées au câblage du bloc logique α2 devraient être effectuées
par un technicien ou un ingénieur compétent en matière de normes électriques
nationales et locales.
Utilisez une alimentation isolée et déconnectez la tension avant tout travail de
câblage.
Les câbles d’entrée et de sortie ne devraient pas passer par un même câble
renfermant plusieurs conducteurs internes ou partager le même fil.
La longueur des lignes pour les signaux d'entrée (du capteur vers l'AL2-2TC-ADP)
ne doit pas dépasser 10 m et celle des lignes des signaux de sortie ne doit pas
dépasser 3 m.
Utilisez pour le raccordement des lignes avec des fils rigides ou flexibles (pour
raccordements sertis) qui sont torsadés soigneusement.
N'utilisez aucun fil flexible avec extrémité brasée sur l'AL2-2TC-ADP.
Afin d’éviter un endommagement du câble, serrer avec un couple de 0,5 - 0,6 Nm.
Ne pas installer le système dans des endroits dont l’atmosphère est riche en
poussières conductrices, en gaz corrosifs ou inflammables. Ne pas l'exposer à
l’humidité ou à la pluie, à une chaleur excessive, à des chocs ou à des vibrations
importantes.
Recouvrir les connecteurs pour éviter de vous blesser en touchant des fils “sous
tension”.
Le bloc logique
α2 doit être installé dans un coffret conforme à la norme DIN 43880
ou dans un boîtier de commande. L'AL2-2TC-ADP doit être protégé contre la
pénétration de corps étranger par un couvercle.
Pour le refroidissement, un espace de 10 mm doit être respecté entre les bords
supérieur et inférieur de l'AL2-2TC-ADP et les autres appareils.
La série
α2 n’est pas conçue pour être utilisée dans des applications
opérationnelles critiques ou à sécurité relative.
MITSUBISHI ELECTRIC décline toute responsabilité pour les dommages
imputables à une installation ou à une utilisation incorrecte des appareils ou des
accessoires.
Prière de lire les manuels du matériel des séries
α2et les manuels de
programmation des séries
α2 pour de plus amples informations.
Avant le réglage de l'offset et du gain sur l'AL2-2TC-ADP, la tension d'alimentation
doit être déconnectée. Vous trouverez de plus amples informations sur le réglage
de l'offset et du gain dans la description du matériel du bloc logique
α2.
La ligne entre le bloc logique
α2 et l'AL2-2TC-ADP doit avoir au maximum une
longueur de 3 m.
La longueur des lignes d'alimentation en courant ne doit pas dépasser 10 m.
Si le capteur est placé à proximité de matériel conducteur, un capteur avec une
isolation pour minimum 500 V doit être utilisé.
Attenzione
Tutte le operazioni relative al cablaggio elettrico dei microcontrollori della serie α2
devono essere effettuate da un tecnico esperto in materia di standard elettrici locali
e nazionali.
Utilizzare un alimentatore di rete isolato e prima di tutti i lavori di cablaggio
disconnettere la tensione di alimentazione.
I cavi di ingresso e di uscita non devono essere instradati nello stesso cavo
multipolare o condividere lo stesso filo.
La lunghezza dei circuiti dei segnali di ingresso (dal sensore fino a AL2-2TC-ADP)
non deve superare i 10 m e quella dei circuiti dei segnalidi uscita non deve superare
i 3 m.
Il cablaggio dovrebbe essere eseguito usando filo singolo e crimpando lo stesso ad
un capicorda o avvolgendo accuratamente la trecciola.
Non usare cavi flessibili con estremità saldata su AL2-2TC-ADP.
Per evitare danneggiamenti del filo, serrare con una coppia di 0,5 - 0,6 Nm.
Non installate in aree soggette a: polvere eccessiva o conduttiva, gas corrosivo o
infiammabile, umidità o pioggia, calore eccessivo, urti regolari o vibrazione
eccessiva.
I connettori devono essere coperti per evitare il rischio di lesioni dovute al contatto
con conduttori “sotto tensione”.
FRE
ITL
I microcontrollori
α
2 devono essere installati in cassette progettate per
l'installazione di dispositivi conformi alla norma DIN 43880. Il modulo AL2-2TC-ADP
deve essere protetto con un involucro per evitare che vi penetrino corpi estranei.
Per il raffreddamento fra la parte in alto ed in basso del modulo AL2-2TC-ADP ed
altri apparecchi, si deve mantenere una distanza di 10 mm.
Il microcontrollore
α
2 non è progettato per essere utilizzao in applicazioni critiche
quali quelle di sicurezza e quelle a rischio di vita.
La MITSUBISHI ELECTRIC non si assume alcuna responsabilità per danni causati
da un’installazione o un funzionamento inadeguato degli apparecchi o degli
accessori.
Per favore leggere il manuale hardware dell'
α
2 e il manuale di programmazione
per ulteriori informazioni.
Prima di regolare offset ed guadagno, la tensione di alimentazione su AL2-2TC-
ADP deve essere scollegata. Istruzioni più dettagliate sulla regolazione di offset e
guadagno si trovano nella descrizione dell´hardware relativa al microcontrollore
α
2.
La lunghezza del cavo di collegamento tra il microcontrollore
α
2 e il modulo AL2-
2TC-ADP non deve superare i 3 m.
La lunghezza delle line di alimentazione di corrente non deve superare 10 m.
Se un sensore viene sistemato vicino a materiale conduttivo, si deve usare un
sensore con una tensione di isolamento di almeno 500 V.
Atención
Un técnico o ingeniero experimentados en los estándares eléctricos nacionales y
locales debe realizar todas las tareas asociadas con el cableado eléctrico del
α
2
.
Utilice un bloque de alimentación aislado y desconecte la tensión antes de realizar
los trabajos de cableado.
Los cables de entrada y salida no deben ser pasados a través del mismo cable
multieje o compartir el mismo alambre.
La longitud de las líneas para las señales de entrada (desde el sensor al AL2-2TC-
ADP) no debe exceder los 10 m, así como los 3 m en caso de las líneas para las
señales de salida.
Para la conexión deben utilizarse líneas con alambres rígidos o flexibles (para
conexión de engarzado a presión) que están cuidadosamente torcidos.
En el AL2-2TC-ADP no han de utilizarse alambres flexibles con extremos soldados.
Para evitar daños del cable, debe aplicarse un torque de 0,5 - 0,6 Nm.
El diseño seguro de
α2 Series significa que el usuario puede instalarlo casi en
todas partes, pero se deberían tomar en consideración los siguientes puntos. No lo
instale en zonas con polvo excesivo o conductor, corrosivos o gas inflamable,
humedad o lluvia, calor excesivo, impactos usuales o vibración excesiva.
Los conectores deben estar recubiertos para prevenir algún daño por contacto con
los alambres “energizados”.
•El
α2 debe instalarse en gabinetes que estén diseñados para el conjunto de
dispositivos, que cumplen con DIN 43880 o en una caja de control. ·El control
α2 y
el AL2-2TC-ADP debe instalarse en un armario de distribución cerrado según la
norma DIN 43880 o bien en una caja de mando. El AL2-2TC-ADP debe protegerse
mediante una cubierta frente al ingreso de cuerpos extraños.
Para la refrigeración debe mantenerse una distancia de 10 mm entre el lado
superior e inferior del AL2-2TC-ADP y de los demás aparatos.
•El
α2 no está diseñado para utilizar en situaciones críticas que ponen la vida en
peligro ni en aplicaciones de seguridad contra averías.
MITSUBISHI ELECTRIC no asumirá responsabilidad alguna de los daños que se
hayan podido producir por causa de una instalación inadecuada o por un uso
inapropiado tanto de las unidades como de los accesorios.
Para mayores informaciones, le rogamos leer los Manuales de Programación y
Hardware de la serie
α2.
Antes de la regulación de la desviación y de la ganancia en el AL2-2TC-ADP debe
desconectarse la tensión de alimentación. Mayor información acerca de la
regulación de la desviación y de la ganancia se encuentra en la descripción de
hardware para el control
α2.
La línea entre el control
α2 y el AL2-2TC-ADP debe tener una longitud máxima de
3 m.
La longitud de las líneas de alimentación de corriente no deben sobrepasar los 10
m.
Al colocar un sensor en la cercanía de material conductor, debe utilizarse un sensor
con una aislación para al menos 500 V.
Viktigt
Alla arbetsuppgifter rörande elektrisk anslutning av styrenheter i α2-serien måste
utföras av tekniker med utbildning i och erfarenhet av lokala och nationella regler för
elarbeten.
Det använda nätaggregatet ska vara isolerat och spänningen vara frånslagen innan
arbeten med kabeldragningen påbörjas.
In- och utgående kablar skall inte dras i samma flerledarkabel eller dela samma
ledare.
Ledningarna för ingångssignalerna (från sensorn till AL2-2TC-ADP) får inte vara
längre än 10 m och ledningarna för utgångssignalerna inte längre än 3 m.
För anslutningen ska ledningar med styva eller flexibla ledare användas (för
crimpanslutning) vilka är omsorgsfullt tvinnade.
Använd inga flexibla ledare med fastlödda ändar på AL2-2TC-ADP.
ESP
SWE
För att undvika att skada kabeln, drar du åt med 0,5 - 0,6 Nm.
Installera inte i områden med mycket damm, ledande damm, korrosiv eller
brännbar gas, fukt eller regn, stark värme, kraftiga stötar eller kraftig vibration.
Anslutningarna måste vara täckta, för att förhindra kontakt med
spänningsförande ledare.
Styrenheten serie
α2 måste installeras i skåp avsedda för montering av
enheter som uppfyller DIN 43880, eller i en styrenhetsbox. AL2-2TC-ADP
måste täckas över för att skydda den mot främmande partiklar.
För att säkerställa kylningen måste avståndet från över- och undersida på AL2-
2TC-ADP till andra apparater uppgå till 10 mm.
α2 är inte avsedd att användas i livskritiska eller felsäkra tillämpningar.
Mitsubishi Electric är under inga omständigheter ersättningsskyldigt eller
ansvarigt för följdskador som kan uppstå till följd av installation eller
användning av utrustningen.
Ytterligare information finns i maskinvaruhandboken för
α2- och
programmeringshandboken för
α2-serien.
Innan offset och förstärkning på AL2-2TC-ADP ställs in måste
försörjningsspänningen slås från. För närmare information om inställning av
offset och förstärkning se beskrivningen av hårdvara för
α2-styrningen.
Ledningen mellan
α2-styrningen och AL2-2TC-ADP får inte vara längre än
max. 3 m.
Elledningen får inte vara längre än 10 m.
Placeras sensorn i närheten av ledande material, skall en sensor med en
isolering på minst 500 V användas.
Внимание
К работам по монтажу контроллера серии
α
2 и модуля AL2-2TC-ADP
допускаются только квалифицированные электрики, прошедшие
подготовку к электромонтажным работам в соответствии с местными и
государственными стандартами.
Используйте изолированный источник питания и отключите
электропитание, прежде чем приступать к каким-либо электромонтажным
работам.
Кабели входных и выходных цепей не должны проходить в одном и том
же многожильном кабеле; в кабелях вх
одных и выходных цепей не
должны использоваться общие провода.
Длина входного кабеля (от датчика к модулю AL2-2TC-ADP) не должна
превышать 10 м, длина выходного кабеля не должна превышать 3 м.
Для подключения следует использовать одинарный провод, обжимку или
аккуратно скрутить многожильный провод.
Не подключайте к модулю AL2-2TC-ADP паяный конец провода
Чтобы не повредить п
ровод, затягивайте его с вращательным моментом
0,5-0,6 Нм.
Не допускается установка устройства в местах с повышенным
содержанием пыли, а также в местах, где пыль является
электропроводящей или в воздухе присутствуют агрессивные или
воспламеняющиеся газы; под дождем или в местах с повышенной
влажностью, либо там, где устройство может быть подвержено
избыточному нагреванию, виб
рации или регулярным ударным
воздействиям.
Соединительные разъемы должны быть закрыты, чтобы избежать
соприкосновения с проводами, находящимся под напряжением.
Контроллер серии
α
2 следует установить в распределительную коробку
или шкаф управления. Распределительная коробка должна быть
снабжена крышкой для модуля AL2-2TC-ADP, чтобы исключить
попадание внутрь посторонних предметов.
Оставьте между верхом и низом модуля AL2-2TC-ADP и окружающими
стенками коробки зазор для вентиляции минимум 10 мм.
Контроллер серии
α
2 не рассчитан на применение в условиях,
требующих полной отказоустойчивости, либо критичных для жизни
человека.
Mitsubishi Electric ни при каких обстоятельствах не несет ответственности
за какие-либо повреждения, которые могут оказаться следствием
установки или эксплуатации данного устройства.
Дальнейшую информацию вы найдете в Руководстве по аппаратной
части контроллера серии
α
2 или в Руководстве по программированию
контроллера серии
α
2.
В модуле AL2-2TC-ADP необходимо выставить величины смещения и
усиления; перед выполнением этой регулировки выключите
электропитание. Для получения дальнейшей информации по регулировке
величин смещения и усиления см. Руководстве по программированию
контроллера серии
α
2.
Максимальное расстояние между контроллером серии
α
2 и модулем
AL2-2TC-ADP не должно превышать 3 м.
Длина кабеля от источника питания не должна превышать 10 м.
Если датчик расположен вблизи проводящего материала, его изоляция
должна быть рассчитана на номинальное напряжение не менее 500 В.
RUS
1. DIMENSIONS
Figure1. Dimensions
Abmessungen
Dimensions
Dimensioni
Dimensiones
Mått
Габариты
Table 1. Allocation of Terminals
Klemmenbelegung
Affectation des bornes
Significato dei morsetti
Ocupaciones de bornes
Plintlayout
Расположение контактных клемм
Ref. Item Description
1
24+
24-
ENG +24V DC Power Supply
GER +24 V DC Eingangsklemme
FRE +24 V CC borne d'entrée
ITL Morsetto di Alimentazione +24 V CC
ESP +24 V CC Terminal de entrada
SWE +24 V DC ingångsklämma
RUS Источник питания +24 В постоянного тока
2
V1+
V1-
ENG Channel 1 Voltage Output Terminal
GER Kanal 1: Spannungsausgang
FRE Canal 1 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 1
ESP Canal 1 Terminal de salida de tensión
SWE Kanal 1 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 1
3
V2+
V2-
ENG Channel 2 Voltage Output Terminal
GER Kanal 2: Spannungsausgang
FRE Canal 2 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 2
ESP Canal 2 Terminal de salida de tensión
SWE Kanal 2 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 2
ENG
GER
FRE
ITL
ESP
SWE
RUS
60(2.37")
90(3.55")
31.0(1.23")
1.5(0.06")
35.5(1.40")
15(0.60")
15(0.60")
8
7
4
5
1 2 3
6
5
Unit: mm(inches)
ENG
GER
FRE
ITL
ESP
SWE
RUS
2. INSTALLATION DIAGRAMS
Figure2. Installation Diagrams
Installations-Skizze
Diagrammes d'installation
Schema di installazione
Esquemas de instalación
Installation
Схемы установки
4
L1+
L1-
ENG Channel 1 K-type Thermocouple Sensor Input Terminal
GER Kanal 1: Anschluss für Thermoelement Typ K
FRE Canal 1: Branchement pour thermocouple de type K
ITL Canale 1: connessione per termoelemento tipo K
ESP Canal 1: Conexión para termoelemento del tipo K
SWE Kanal 1: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 1
5SLD
ENG Shield Grounding Terminal
GER Masseanschluss für die Abschirmung
FRE Borne de masse pour le blindage
ITL Connessione per la schermatura
ESP Conexión a masa para el blindaje
SWE Anslutning av skärm
RUS Контактная клемма заземления экрана
6
L2+
L2-
ENG Channel 2 K-type Thermocouple Sensor Input Terminal
GER Kanal 2: Anschluss für Thermoelement Typ K
FRE Canal 2: Branchement pour thermocouple de type K
ITL Canale 2: connessione per termoelemento tipo K
ESP Canal 2: Conexión para termoelemento del tipo K
SWE Kanal 2: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 2
7
ENG Jumper pins for adjustment
GER Jumper zur Einstellung des Moduls
FRE Cavalier pour le réglage du module
ITL Ponticello per l'impostazione del modulo
ESP Puente para la regulación del módulo
SWE Jumper för inställning av modul
RUS Штырьки перемычек для настройки
8
ENG Power LED
GER Power-LED zur Anzeige der Betriebsbereitschaft
FRE DEL alimentation pour l'affichage de l'état de service
ITL
Led "POWER" per l'indicazione dello stato di
funzionamento del modulo.
ESP LED de potencia, indica la disposición de servicio
SWE Power-LED, indikerar spänningsmatning
RUS Светодиодный индикатор подачи питания
Ref. Item Description
ENG
GER
FRE
ITL
ESP
SWE
RUS
Attach
(1)
(2)
(
1
)
(2)
Release
When installing the AL2-2TC-ADP module refer to Figure 2.
Units can be snap mounted to 35mm DIN rail (DIN EN 50022). To release pull the spring
loaded clips away from the rail and slide the unit off and up.
a) To Attach
Align the upper side of the AL2-2TC-ADP DIN rail mounting groove with the DIN rail
(1) and push it onto the rail (2).
b) To Release
Pull the DIN rail hook (1) and remove the AL2-2TC-ADP (2).
Installieren Sie das AL2-2TC-ADP so, wie in Figure 2 gezeigt.
Das Modul kann auf eine DIN-Schiene (35 mm, DIN EN 50022) montiert werden. Zur
Demontage ziehen Sie an den mit einer Feder versehenen Riegel und nehmen das Modul
von der Schiene.
a) Montage
Setzen Sie das AL2-2TC-ADP mit der oberen Seite auf die DIN-Schiene (1) und
drücken Sie das Modul auf die Schiene (2).
b) Demontage
Ziehen Sie den Riegel nach unten (1) und entfernen Sie das AL2-2TC-ADP (2).
Installez l'AL2-2TC-ADP comme indiqué dans la figure 2.
Le module peut être monté sur un rail DIN (35 mm, DIN EN 50022). Pour le démontage,
tirez sur le verrouillage équipé d'un ressort et enlevez le module du rail.
a) Montage
Placez l'AL2-2TC-ADP avec la face supérieure sur le rail DIN (1) et POUSSEZ le
module sur le rail (2).
b) Démontage
Tirez le verrouillage vers le bas (1) et enlevez l'AL2-2TC-ADP (2).
Installare AL2-2TC-ADP come illustrato nella figura 2.
Il modulo può essere montato su una guida (35 mm, DIN EN 50022). Per lo smontaggio
spingere verso il basso il modulo provvisto di una molla e togliere il modulo dalla guida.
a) Montaggio
Mettere il modulo AL2-2TC-ADP con il lato superiore sulla guida Din (1) e premere
il modulo sulla guida (2).
b) Smontaggio
Spingere il blocco verso il basso (1) e toglierlo (2).
Instale el AL2-2TC-ADP según las indicaciones en la figura 2.
El módulo puede montarse sobre un riel DIN (35 mm, DIN NE 50022). Para el desmontaje
debe extraerse el pasador equipado con un resorte y retirarse el módulo del riel.
a) Montaje
Coloque el AL2-2TC-ADP con la parte superior sobre el riel DIN (1) y empuje el
módulo sobre el riel (2).
b) Desmontaje
Extraiga el pasador hacia abajo (1) y retire el AL2-2TC-ADP (2).
För installationen av AL2-2TC-ADP se bild 2.
Modulen kan monteras på en DIN-skena (35 mm, DIN EN 50022). För demontering drag i
den fjäderförsedda regeln och lyft bort modulen från skenan.
a) Montage
Placera AL2-2TC-ADP med den övre sidan på DIN-skenan (1) och tryck fast mod-
ulen på skenan (2).
b) Demontage
Drag regeln nedåt (1) och lyft bort AL2-2TC-ADP (2).
Перед установкой модуля AL2-2TC-ADP ознакомьтесь с рис. 2.
Устройства можно монтировать на защелке к 35 мм рельсу DIN (DIN EN 50022).
Чтобы снять устройство с рельса, оттяните подпружиненные зажимы от рельса и
сдвиньте устройство вверх.
a) Для установки: совместите верхний край канавки на корпусе модуля AL2-2TC-
ADP с рельсом DIN (1) и защелкните его на рельсе (2).
b) Для съема
Оттяните крючок (1) и снимите модуль AL2-2TC-ADP (2) с рельса DIN.
3. WIRING DIAGRAMS
Figure3. End Processing of Cable
Bearbeitung der Leiterenden
Manipulation de fin de câble
Preparazione del cavo
Fin de procesamiento del cable
Kabelns ände
Оконцевание кабеля
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Wire the Inputs and Outputs using 26 - 12 AWG wire (0.13 mm
2
-
3.31 mm
2
).
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Multicore cable: Remove sheath, twist core wires, then connect
cable (or use a crimp terminal).
Single cable: Remove sheath, then connect cable.
Verwenden Sie für die Eingänge und Ausgänge Leitungen mit einem
Aderquerschnitt von 0,13 mm
2
- 3,31 mm
2
(26 - 12 AWG).
Um eine Beschädigung der Leitungen zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Flexible Leitung: Isolation entfernen, Aderendhülsen anbringen
oder Litze verdrillen und Leitung anschließen.
Starre Leitung: Isolation entfernen und Leitung anschließen.
Raccordez les entrées et les sorties avec des fils de 0,13 mm
2
à
3,31 mm
2
(26 - 12 AWG).
Afin d'éviter un endommagement du câble, serrer avec un couple de
0,5-0,6 Nm.
Ligne flexible: Enlever la gaine, le fil central de torsion et
connecter ensuite le câble (ou utiliser une borne
sertie).
Câble simple: Enlever la gaine et connecter ensuite le câble.
Collegare gli ingressi e le uscite con fili di diam. da 0,13 mm
2
- 3,31
mm
2
.
Per evitare di danneggiare il filo, serrare con una coppia di 0,5-0,6
Nm.
Cavo a trecciola: Togliere la guaina, torcere l´anima dei fili, poi
collegare il cavo (o usare un capocorda a
crimpare).
Cavo rigido: Togliere la guaina, poi collegare il cavo.
Alambrar las entradas y salidas usando alambre de 0,13 mm
2
- 3,31
mm
2
(26 - 12 AWG).
Para evitar daños del cable, debe aplicarse un torque de 0,5-0,6
Nm.
Línea flexible: Remover el revestimiento, retorcer las almas y
conectar luego el cable (o utilizar un terminal de
presión).
Cable único: Remover el revestimiento y conectar luego el
cable.
Anslut in-och utgångarna med kabel 26 -12 AWG (0,13 - 3,31 mm
2
).
För att undvika att skada kabeln, drar du åt med 0,5-0,6 Nm.
Flexibel ledning: Avlägsna höljet, tvinna trådarna och anslut
kabeln (eller använd klämkoppling).
Entrådig kabel: Avlägsna höljet och anslut kabeln.
Подключение входных и выходных цепей производится с
помощью проводов сечением 26 – 12 по стандарту AWG (0,13
мм
2
– 3,31 мм
2
).
Чтобы не повредить провод, затягивайте его с вращательным
моментом 0,5-0,6 Нм
Многожильный кабель: удалите изоляцию, скрутите провода,
затем подсоедините кабель (или
используйте обжимку)
Одинарный провод: удалите изоляцию, затем
подсоедините провод
4. WIRING
Note:
When wiring DC supplies the "positive" cable should be con-
nected to the "+" terminal and the negative cable should be con-
nected to the "-" terminal. On no account should the power supply
terminals be connected to any other terminal on the unit. Revers-
ing the terminals will seriously damage the AL2-2TC-ADP expan-
sion module.
Under no circumstances should AC voltage be used as the AL2-
2TC-ADP expansion module will be seriously damaged.
Do not lay signal cabling near to high voltage power cables or
house them in the same trunking duct. Effects of noise or surge
induction may occur. Keep signal cables a safe of more than 100
mm (3.94") distance away from these power cables.
The AL2-2TC-ADP and
α2 Series main unit must use the same
power supply.
7mm(0.276") ±0.5mm(0.02")
26 -12 AWG
Temperature Rating: Min. 80ºC (176ºF)
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
JY997D09501H
AL2-2TC-ADP
Installation Manual Installationsanleitung
Manuel d’installation Manuale di installazione
Manual de Instalación Installationshandbok
Руководство по установке
JY997D09501H
Caution
Persons trained in the local and national electrical standards must perform all
tasks associated with wiring the
α2 Series Controller and AL2-2TC-ADP.
Please use an isolated Power supply and turn off the Power before any wiring
operation is performed.
Input and Output cables should not be run through the same multicore cable or
share the same wire.
Input cable (from sensor to AL2-2TC-ADP) must be less than 10m (32’81’’)
and the output cable length must be less than 3m (9' 10").
The wire should be used as a single cable or the multicore wires (can be used
with a crimp terminal) should be carefully twisted together.
Do not connect a soldered wire end to the AL2-2TC-ADP.
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Do not install in areas with: excessive or conductive dust, corrosive or
flammable gas, moisture or rain, excessive heat, regular impact shocks or
excessive vibration.
The connectors must be covered to prevent contact with “Live” wires.
The
α2 Series Controller and AL2-2TC-ADP must be installed in a distribution
box or a control cabinet. The distribution box should be equipped with a cover
for the AL2-2TC-ADP module to avoid any possible foreign objects from falling
inside
Leave a minimum of 10mm (0.40") of space for ventilation between the top and
bottom edges of the AL2-2TC-ADP and the enclosure walls.
The
α2 Series is not designed to be used in life critical or fail safe applications.
Under no circumstances will Mitsubishi Electric be liable or responsible for any
consequential damage that may arise as a result of the installation or use of
this equipment.
Please read the
α2 Series Hardware and α2 Series Programming Manuals
for further information.
The AL2-2TC-ADP should be adjusted for offset and gain purposes, therefore,
turn off the Power before performing the adjustment wiring. Please refer to the
α2 Hardware manual for further details concerning offset and gain adjustment.
The maximum distance between the
α2 Series Controller and the AL2-2TC-
ADP should be 3m (9' 10") or less.
The power cable should be less than 10 m (32' 81") in length.
A sensor with insulation rated for 500 V or more should be used when the
sensor is placed near a conductive material.
Achtung
Nur speziell ausgebildetes Personal darf die elektrische Verdrahtung der
Geräte vornehmen. Sollten Sie spezialisierte Unterstützung brauchen, wenden
Sie sich an eine anerkannt ausgebildete Elektrofachkraft, die mit den lokalen
und nationalen Sicherheitsstandards der Automatisierungstechnik vertraut ist.
Verwenden Sie ein isoliertes Netzgerät, und schalten Sie vor allen
Verdrahtungsarbeiten die Spannung ab.
Die Ein- und Ausgangskabel dürfen nicht durch das gleiche Multikernkabel
oder den gleichen Kabelbaum verlegt werden.
Die Länge der Leitungen für Eingangssignale (vom Sensor zum AL2-2TC-
ADP) darf 10 m und die der Leitungen für Ausgangssignale darf 3 m nicht
überschreiten.
Verwenden Sie zum Anschluss Leitungen mit starren oder flexiblen Drähten
(für Crimp-Anschluss), die sorgfältig verdrillt sind.
Verwenden Sie keine flexible Drähte mit verlötetem Ende an einem AL2-2TC-
ADP.
Um eine Beschädigung der Kabel zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Die Geräte dürfen den folgenden Umgebungsbedingungen nicht ausgesetzt
werden: Umgebungen mit einem hohen Grad an leitfähigen Stäuben,
Korrosion, entzündbaren Gasen, Nebel, Regen, direkte Sonnenbestrahlung,
große Hitze, starke Schockwellen und Vibrationen.
Die Anschlüsse müssen abgedeckt werden, um Stromberührung zu
vermeiden.
•Die
α2-Steuerung und das AL2-2TC-ADP müssen in einen Schaltschrank
nach DIN 43880 oder einen Steuerkasten eingebaut werden. Das AL2-2TC-
ADP muss durch eine Abdeckung vor dem Eindringen von Fremdkörpern
geschützt werden.
Zur Kühlung muss zwischen der oberen und unteren Seite des AL2-2TC-ADP
und anderen Geräten ein Abstand von 10 mm eingehalten werden.
ENG
GER
•Die α2-Steuerung wurde nicht für lebenserhaltende oder selbstüberwachende
Anwendungen entwickelt.
MITSUBISHI ELECTRIC übernimmt unter keinen Umständen die Haftung oder
Verantwortung für einen Schaden, der aus einer unsachgemäßen Installation oder
Anwendung der Geräte oder des Zubehörs entstanden ist.
Weitere Informationen entnehmen Sie bitte der Hardware- und der
Programmieranleitung zur
α2-Steuerung.
Vor der Einstellung von Offset und Verstärkung am AL2-2TC-ADP muss die
Versorgungspannung ausgeschaltet werden. Nähere Hinweise zur Offset- und
Verstärkungseinstellung finden Sie in der Hardware-Beschreibung zur
α2-
Steuerung.
Die Leitung zwischen der
α2-Steuerung und dem AL2-2TC-ADP darf max. 3 m lang
sein.
Die Länge der Stromversorgungsleitungen darf 10 m nicht überschreiten.
Wird der Sensor in der Nähe von leitfähigen Material platziert, muss ein Sensor mit
einer Isolierung für min. 500 V verwendet werden.
Attention
Toutes les opérations liées au câblage du bloc logique α2 devraient être effectuées
par un technicien ou un ingénieur compétent en matière de normes électriques
nationales et locales.
Utilisez une alimentation isolée et déconnectez la tension avant tout travail de
câblage.
Les câbles d’entrée et de sortie ne devraient pas passer par un même câble
renfermant plusieurs conducteurs internes ou partager le même fil.
La longueur des lignes pour les signaux d'entrée (du capteur vers l'AL2-2TC-ADP)
ne doit pas dépasser 10 m et celle des lignes des signaux de sortie ne doit pas
dépasser 3 m.
Utilisez pour le raccordement des lignes avec des fils rigides ou flexibles (pour
raccordements sertis) qui sont torsadés soigneusement.
N'utilisez aucun fil flexible avec extrémité brasée sur l'AL2-2TC-ADP.
Afin d’éviter un endommagement du câble, serrer avec un couple de 0,5 - 0,6 Nm.
Ne pas installer le système dans des endroits dont l’atmosphère est riche en
poussières conductrices, en gaz corrosifs ou inflammables. Ne pas l'exposer à
l’humidité ou à la pluie, à une chaleur excessive, à des chocs ou à des vibrations
importantes.
Recouvrir les connecteurs pour éviter de vous blesser en touchant des fils “sous
tension”.
Le bloc logique
α2 doit être installé dans un coffret conforme à la norme DIN 43880
ou dans un boîtier de commande. L'AL2-2TC-ADP doit être protégé contre la
pénétration de corps étranger par un couvercle.
Pour le refroidissement, un espace de 10 mm doit être respecté entre les bords
supérieur et inférieur de l'AL2-2TC-ADP et les autres appareils.
La série
α2 n’est pas conçue pour être utilisée dans des applications
opérationnelles critiques ou à sécurité relative.
MITSUBISHI ELECTRIC décline toute responsabilité pour les dommages
imputables à une installation ou à une utilisation incorrecte des appareils ou des
accessoires.
Prière de lire les manuels du matériel des séries
α2et les manuels de
programmation des séries
α2 pour de plus amples informations.
Avant le réglage de l'offset et du gain sur l'AL2-2TC-ADP, la tension d'alimentation
doit être déconnectée. Vous trouverez de plus amples informations sur le réglage
de l'offset et du gain dans la description du matériel du bloc logique
α2.
La ligne entre le bloc logique
α2 et l'AL2-2TC-ADP doit avoir au maximum une
longueur de 3 m.
La longueur des lignes d'alimentation en courant ne doit pas dépasser 10 m.
Si le capteur est placé à proximité de matériel conducteur, un capteur avec une
isolation pour minimum 500 V doit être utilisé.
Attenzione
Tutte le operazioni relative al cablaggio elettrico dei microcontrollori della serie α2
devono essere effettuate da un tecnico esperto in materia di standard elettrici locali
e nazionali.
Utilizzare un alimentatore di rete isolato e prima di tutti i lavori di cablaggio
disconnettere la tensione di alimentazione.
I cavi di ingresso e di uscita non devono essere instradati nello stesso cavo
multipolare o condividere lo stesso filo.
La lunghezza dei circuiti dei segnali di ingresso (dal sensore fino a AL2-2TC-ADP)
non deve superare i 10 m e quella dei circuiti dei segnalidi uscita non deve superare
i 3 m.
Il cablaggio dovrebbe essere eseguito usando filo singolo e crimpando lo stesso ad
un capicorda o avvolgendo accuratamente la trecciola.
Non usare cavi flessibili con estremità saldata su AL2-2TC-ADP.
Per evitare danneggiamenti del filo, serrare con una coppia di 0,5 - 0,6 Nm.
Non installate in aree soggette a: polvere eccessiva o conduttiva, gas corrosivo o
infiammabile, umidità o pioggia, calore eccessivo, urti regolari o vibrazione
eccessiva.
I connettori devono essere coperti per evitare il rischio di lesioni dovute al contatto
con conduttori “sotto tensione”.
FRE
ITL
I microcontrollori
α
2 devono essere installati in cassette progettate per
l'installazione di dispositivi conformi alla norma DIN 43880. Il modulo AL2-2TC-ADP
deve essere protetto con un involucro per evitare che vi penetrino corpi estranei.
Per il raffreddamento fra la parte in alto ed in basso del modulo AL2-2TC-ADP ed
altri apparecchi, si deve mantenere una distanza di 10 mm.
Il microcontrollore
α
2 non è progettato per essere utilizzao in applicazioni critiche
quali quelle di sicurezza e quelle a rischio di vita.
La MITSUBISHI ELECTRIC non si assume alcuna responsabilità per danni causati
da un’installazione o un funzionamento inadeguato degli apparecchi o degli
accessori.
Per favore leggere il manuale hardware dell'
α
2 e il manuale di programmazione
per ulteriori informazioni.
Prima di regolare offset ed guadagno, la tensione di alimentazione su AL2-2TC-
ADP deve essere scollegata. Istruzioni più dettagliate sulla regolazione di offset e
guadagno si trovano nella descrizione dell´hardware relativa al microcontrollore
α
2.
La lunghezza del cavo di collegamento tra il microcontrollore
α
2 e il modulo AL2-
2TC-ADP non deve superare i 3 m.
La lunghezza delle line di alimentazione di corrente non deve superare 10 m.
Se un sensore viene sistemato vicino a materiale conduttivo, si deve usare un
sensore con una tensione di isolamento di almeno 500 V.
Atención
Un técnico o ingeniero experimentados en los estándares eléctricos nacionales y
locales debe realizar todas las tareas asociadas con el cableado eléctrico del
α
2
.
Utilice un bloque de alimentación aislado y desconecte la tensión antes de realizar
los trabajos de cableado.
Los cables de entrada y salida no deben ser pasados a través del mismo cable
multieje o compartir el mismo alambre.
La longitud de las líneas para las señales de entrada (desde el sensor al AL2-2TC-
ADP) no debe exceder los 10 m, así como los 3 m en caso de las líneas para las
señales de salida.
Para la conexión deben utilizarse líneas con alambres rígidos o flexibles (para
conexión de engarzado a presión) que están cuidadosamente torcidos.
En el AL2-2TC-ADP no han de utilizarse alambres flexibles con extremos soldados.
Para evitar daños del cable, debe aplicarse un torque de 0,5 - 0,6 Nm.
El diseño seguro de
α2 Series significa que el usuario puede instalarlo casi en
todas partes, pero se deberían tomar en consideración los siguientes puntos. No lo
instale en zonas con polvo excesivo o conductor, corrosivos o gas inflamable,
humedad o lluvia, calor excesivo, impactos usuales o vibración excesiva.
Los conectores deben estar recubiertos para prevenir algún daño por contacto con
los alambres “energizados”.
•El
α2 debe instalarse en gabinetes que estén diseñados para el conjunto de
dispositivos, que cumplen con DIN 43880 o en una caja de control. ·El control
α2 y
el AL2-2TC-ADP debe instalarse en un armario de distribución cerrado según la
norma DIN 43880 o bien en una caja de mando. El AL2-2TC-ADP debe protegerse
mediante una cubierta frente al ingreso de cuerpos extraños.
Para la refrigeración debe mantenerse una distancia de 10 mm entre el lado
superior e inferior del AL2-2TC-ADP y de los demás aparatos.
•El
α2 no está diseñado para utilizar en situaciones críticas que ponen la vida en
peligro ni en aplicaciones de seguridad contra averías.
MITSUBISHI ELECTRIC no asumirá responsabilidad alguna de los daños que se
hayan podido producir por causa de una instalación inadecuada o por un uso
inapropiado tanto de las unidades como de los accesorios.
Para mayores informaciones, le rogamos leer los Manuales de Programación y
Hardware de la serie
α2.
Antes de la regulación de la desviación y de la ganancia en el AL2-2TC-ADP debe
desconectarse la tensión de alimentación. Mayor información acerca de la
regulación de la desviación y de la ganancia se encuentra en la descripción de
hardware para el control
α2.
La línea entre el control
α2 y el AL2-2TC-ADP debe tener una longitud máxima de
3 m.
La longitud de las líneas de alimentación de corriente no deben sobrepasar los 10
m.
Al colocar un sensor en la cercanía de material conductor, debe utilizarse un sensor
con una aislación para al menos 500 V.
Viktigt
Alla arbetsuppgifter rörande elektrisk anslutning av styrenheter i α2-serien måste
utföras av tekniker med utbildning i och erfarenhet av lokala och nationella regler för
elarbeten.
Det använda nätaggregatet ska vara isolerat och spänningen vara frånslagen innan
arbeten med kabeldragningen påbörjas.
In- och utgående kablar skall inte dras i samma flerledarkabel eller dela samma
ledare.
Ledningarna för ingångssignalerna (från sensorn till AL2-2TC-ADP) får inte vara
längre än 10 m och ledningarna för utgångssignalerna inte längre än 3 m.
För anslutningen ska ledningar med styva eller flexibla ledare användas (för
crimpanslutning) vilka är omsorgsfullt tvinnade.
Använd inga flexibla ledare med fastlödda ändar på AL2-2TC-ADP.
ESP
SWE
För att undvika att skada kabeln, drar du åt med 0,5 - 0,6 Nm.
Installera inte i områden med mycket damm, ledande damm, korrosiv eller
brännbar gas, fukt eller regn, stark värme, kraftiga stötar eller kraftig vibration.
Anslutningarna måste vara täckta, för att förhindra kontakt med
spänningsförande ledare.
Styrenheten serie
α2 måste installeras i skåp avsedda för montering av
enheter som uppfyller DIN 43880, eller i en styrenhetsbox. AL2-2TC-ADP
måste täckas över för att skydda den mot främmande partiklar.
För att säkerställa kylningen måste avståndet från över- och undersida på AL2-
2TC-ADP till andra apparater uppgå till 10 mm.
α2 är inte avsedd att användas i livskritiska eller felsäkra tillämpningar.
Mitsubishi Electric är under inga omständigheter ersättningsskyldigt eller
ansvarigt för följdskador som kan uppstå till följd av installation eller
användning av utrustningen.
Ytterligare information finns i maskinvaruhandboken för
α2- och
programmeringshandboken för
α2-serien.
Innan offset och förstärkning på AL2-2TC-ADP ställs in måste
försörjningsspänningen slås från. För närmare information om inställning av
offset och förstärkning se beskrivningen av hårdvara för
α2-styrningen.
Ledningen mellan
α2-styrningen och AL2-2TC-ADP får inte vara längre än
max. 3 m.
Elledningen får inte vara längre än 10 m.
Placeras sensorn i närheten av ledande material, skall en sensor med en
isolering på minst 500 V användas.
Внимание
К работам по монтажу контроллера серии
α
2 и модуля AL2-2TC-ADP
допускаются только квалифицированные электрики, прошедшие
подготовку к электромонтажным работам в соответствии с местными и
государственными стандартами.
Используйте изолированный источник питания и отключите
электропитание, прежде чем приступать к каким-либо электромонтажным
работам.
Кабели входных и выходных цепей не должны проходить в одном и том
же многожильном кабеле; в кабелях вх
одных и выходных цепей не
должны использоваться общие провода.
Длина входного кабеля (от датчика к модулю AL2-2TC-ADP) не должна
превышать 10 м, длина выходного кабеля не должна превышать 3 м.
Для подключения следует использовать одинарный провод, обжимку или
аккуратно скрутить многожильный провод.
Не подключайте к модулю AL2-2TC-ADP паяный конец провода
Чтобы не повредить п
ровод, затягивайте его с вращательным моментом
0,5-0,6 Нм.
Не допускается установка устройства в местах с повышенным
содержанием пыли, а также в местах, где пыль является
электропроводящей или в воздухе присутствуют агрессивные или
воспламеняющиеся газы; под дождем или в местах с повышенной
влажностью, либо там, где устройство может быть подвержено
избыточному нагреванию, виб
рации или регулярным ударным
воздействиям.
Соединительные разъемы должны быть закрыты, чтобы избежать
соприкосновения с проводами, находящимся под напряжением.
Контроллер серии
α
2 следует установить в распределительную коробку
или шкаф управления. Распределительная коробка должна быть
снабжена крышкой для модуля AL2-2TC-ADP, чтобы исключить
попадание внутрь посторонних предметов.
Оставьте между верхом и низом модуля AL2-2TC-ADP и окружающими
стенками коробки зазор для вентиляции минимум 10 мм.
Контроллер серии
α
2 не рассчитан на применение в условиях,
требующих полной отказоустойчивости, либо критичных для жизни
человека.
Mitsubishi Electric ни при каких обстоятельствах не несет ответственности
за какие-либо повреждения, которые могут оказаться следствием
установки или эксплуатации данного устройства.
Дальнейшую информацию вы найдете в Руководстве по аппаратной
части контроллера серии
α
2 или в Руководстве по программированию
контроллера серии
α
2.
В модуле AL2-2TC-ADP необходимо выставить величины смещения и
усиления; перед выполнением этой регулировки выключите
электропитание. Для получения дальнейшей информации по регулировке
величин смещения и усиления см. Руководстве по программированию
контроллера серии
α
2.
Максимальное расстояние между контроллером серии
α
2 и модулем
AL2-2TC-ADP не должно превышать 3 м.
Длина кабеля от источника питания не должна превышать 10 м.
Если датчик расположен вблизи проводящего материала, его изоляция
должна быть рассчитана на номинальное напряжение не менее 500 В.
RUS
1. DIMENSIONS
Figure1. Dimensions
Abmessungen
Dimensions
Dimensioni
Dimensiones
Mått
Габариты
Table 1. Allocation of Terminals
Klemmenbelegung
Affectation des bornes
Significato dei morsetti
Ocupaciones de bornes
Plintlayout
Расположение контактных клемм
Ref. Item Description
1
24+
24-
ENG +24V DC Power Supply
GER +24 V DC Eingangsklemme
FRE +24 V CC borne d'entrée
ITL Morsetto di Alimentazione +24 V CC
ESP +24 V CC Terminal de entrada
SWE +24 V DC ingångsklämma
RUS Источник питания +24 В постоянного тока
2
V1+
V1-
ENG Channel 1 Voltage Output Terminal
GER Kanal 1: Spannungsausgang
FRE Canal 1 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 1
ESP Canal 1 Terminal de salida de tensión
SWE Kanal 1 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 1
3
V2+
V2-
ENG Channel 2 Voltage Output Terminal
GER Kanal 2: Spannungsausgang
FRE Canal 2 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 2
ESP Canal 2 Terminal de salida de tensión
SWE Kanal 2 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 2
ENG
GER
FRE
ITL
ESP
SWE
RUS
60(2.37")
90(3.55")
31.0(1.23")
1.5(0.06")
35.5(1.40")
15(0.60")
15(0.60")
8
7
4
5
1 2 3
6
5
Unit: mm(inches)
ENG
GER
FRE
ITL
ESP
SWE
RUS
2. INSTALLATION DIAGRAMS
Figure2. Installation Diagrams
Installations-Skizze
Diagrammes d'installation
Schema di installazione
Esquemas de instalación
Installation
Схемы установки
4
L1+
L1-
ENG Channel 1 K-type Thermocouple Sensor Input Terminal
GER Kanal 1: Anschluss für Thermoelement Typ K
FRE Canal 1: Branchement pour thermocouple de type K
ITL Canale 1: connessione per termoelemento tipo K
ESP Canal 1: Conexión para termoelemento del tipo K
SWE Kanal 1: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 1
5SLD
ENG Shield Grounding Terminal
GER Masseanschluss für die Abschirmung
FRE Borne de masse pour le blindage
ITL Connessione per la schermatura
ESP Conexión a masa para el blindaje
SWE Anslutning av skärm
RUS Контактная клемма заземления экрана
6
L2+
L2-
ENG Channel 2 K-type Thermocouple Sensor Input Terminal
GER Kanal 2: Anschluss für Thermoelement Typ K
FRE Canal 2: Branchement pour thermocouple de type K
ITL Canale 2: connessione per termoelemento tipo K
ESP Canal 2: Conexión para termoelemento del tipo K
SWE Kanal 2: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 2
7
ENG Jumper pins for adjustment
GER Jumper zur Einstellung des Moduls
FRE Cavalier pour le réglage du module
ITL Ponticello per l'impostazione del modulo
ESP Puente para la regulación del módulo
SWE Jumper för inställning av modul
RUS Штырьки перемычек для настройки
8
ENG Power LED
GER Power-LED zur Anzeige der Betriebsbereitschaft
FRE DEL alimentation pour l'affichage de l'état de service
ITL
Led "POWER" per l'indicazione dello stato di
funzionamento del modulo.
ESP LED de potencia, indica la disposición de servicio
SWE Power-LED, indikerar spänningsmatning
RUS Светодиодный индикатор подачи питания
Ref. Item Description
ENG
GER
FRE
ITL
ESP
SWE
RUS
Attach
(1)
(2)
(
1
)
(2)
Release
When installing the AL2-2TC-ADP module refer to Figure 2.
Units can be snap mounted to 35mm DIN rail (DIN EN 50022). To release pull the spring
loaded clips away from the rail and slide the unit off and up.
a) To Attach
Align the upper side of the AL2-2TC-ADP DIN rail mounting groove with the DIN rail
(1) and push it onto the rail (2).
b) To Release
Pull the DIN rail hook (1) and remove the AL2-2TC-ADP (2).
Installieren Sie das AL2-2TC-ADP so, wie in Figure 2 gezeigt.
Das Modul kann auf eine DIN-Schiene (35 mm, DIN EN 50022) montiert werden. Zur
Demontage ziehen Sie an den mit einer Feder versehenen Riegel und nehmen das Modul
von der Schiene.
a) Montage
Setzen Sie das AL2-2TC-ADP mit der oberen Seite auf die DIN-Schiene (1) und
drücken Sie das Modul auf die Schiene (2).
b) Demontage
Ziehen Sie den Riegel nach unten (1) und entfernen Sie das AL2-2TC-ADP (2).
Installez l'AL2-2TC-ADP comme indiqué dans la figure 2.
Le module peut être monté sur un rail DIN (35 mm, DIN EN 50022). Pour le démontage,
tirez sur le verrouillage équipé d'un ressort et enlevez le module du rail.
a) Montage
Placez l'AL2-2TC-ADP avec la face supérieure sur le rail DIN (1) et POUSSEZ le
module sur le rail (2).
b) Démontage
Tirez le verrouillage vers le bas (1) et enlevez l'AL2-2TC-ADP (2).
Installare AL2-2TC-ADP come illustrato nella figura 2.
Il modulo può essere montato su una guida (35 mm, DIN EN 50022). Per lo smontaggio
spingere verso il basso il modulo provvisto di una molla e togliere il modulo dalla guida.
a) Montaggio
Mettere il modulo AL2-2TC-ADP con il lato superiore sulla guida Din (1) e premere
il modulo sulla guida (2).
b) Smontaggio
Spingere il blocco verso il basso (1) e toglierlo (2).
Instale el AL2-2TC-ADP según las indicaciones en la figura 2.
El módulo puede montarse sobre un riel DIN (35 mm, DIN NE 50022). Para el desmontaje
debe extraerse el pasador equipado con un resorte y retirarse el módulo del riel.
a) Montaje
Coloque el AL2-2TC-ADP con la parte superior sobre el riel DIN (1) y empuje el
módulo sobre el riel (2).
b) Desmontaje
Extraiga el pasador hacia abajo (1) y retire el AL2-2TC-ADP (2).
För installationen av AL2-2TC-ADP se bild 2.
Modulen kan monteras på en DIN-skena (35 mm, DIN EN 50022). För demontering drag i
den fjäderförsedda regeln och lyft bort modulen från skenan.
a) Montage
Placera AL2-2TC-ADP med den övre sidan på DIN-skenan (1) och tryck fast mod-
ulen på skenan (2).
b) Demontage
Drag regeln nedåt (1) och lyft bort AL2-2TC-ADP (2).
Перед установкой модуля AL2-2TC-ADP ознакомьтесь с рис. 2.
Устройства можно монтировать на защелке к 35 мм рельсу DIN (DIN EN 50022).
Чтобы снять устройство с рельса, оттяните подпружиненные зажимы от рельса и
сдвиньте устройство вверх.
a) Для установки: совместите верхний край канавки на корпусе модуля AL2-2TC-
ADP с рельсом DIN (1) и защелкните его на рельсе (2).
b) Для съема
Оттяните крючок (1) и снимите модуль AL2-2TC-ADP (2) с рельса DIN.
3. WIRING DIAGRAMS
Figure3. End Processing of Cable
Bearbeitung der Leiterenden
Manipulation de fin de câble
Preparazione del cavo
Fin de procesamiento del cable
Kabelns ände
Оконцевание кабеля
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Wire the Inputs and Outputs using 26 - 12 AWG wire (0.13 mm
2
-
3.31 mm
2
).
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Multicore cable: Remove sheath, twist core wires, then connect
cable (or use a crimp terminal).
Single cable: Remove sheath, then connect cable.
Verwenden Sie für die Eingänge und Ausgänge Leitungen mit einem
Aderquerschnitt von 0,13 mm
2
- 3,31 mm
2
(26 - 12 AWG).
Um eine Beschädigung der Leitungen zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Flexible Leitung: Isolation entfernen, Aderendhülsen anbringen
oder Litze verdrillen und Leitung anschließen.
Starre Leitung: Isolation entfernen und Leitung anschließen.
Raccordez les entrées et les sorties avec des fils de 0,13 mm
2
à
3,31 mm
2
(26 - 12 AWG).
Afin d'éviter un endommagement du câble, serrer avec un couple de
0,5-0,6 Nm.
Ligne flexible: Enlever la gaine, le fil central de torsion et
connecter ensuite le câble (ou utiliser une borne
sertie).
Câble simple: Enlever la gaine et connecter ensuite le câble.
Collegare gli ingressi e le uscite con fili di diam. da 0,13 mm
2
- 3,31
mm
2
.
Per evitare di danneggiare il filo, serrare con una coppia di 0,5-0,6
Nm.
Cavo a trecciola: Togliere la guaina, torcere l´anima dei fili, poi
collegare il cavo (o usare un capocorda a
crimpare).
Cavo rigido: Togliere la guaina, poi collegare il cavo.
Alambrar las entradas y salidas usando alambre de 0,13 mm
2
- 3,31
mm
2
(26 - 12 AWG).
Para evitar daños del cable, debe aplicarse un torque de 0,5-0,6
Nm.
Línea flexible: Remover el revestimiento, retorcer las almas y
conectar luego el cable (o utilizar un terminal de
presión).
Cable único: Remover el revestimiento y conectar luego el
cable.
Anslut in-och utgångarna med kabel 26 -12 AWG (0,13 - 3,31 mm
2
).
För att undvika att skada kabeln, drar du åt med 0,5-0,6 Nm.
Flexibel ledning: Avlägsna höljet, tvinna trådarna och anslut
kabeln (eller använd klämkoppling).
Entrådig kabel: Avlägsna höljet och anslut kabeln.
Подключение входных и выходных цепей производится с
помощью проводов сечением 26 – 12 по стандарту AWG (0,13
мм
2
– 3,31 мм
2
).
Чтобы не повредить провод, затягивайте его с вращательным
моментом 0,5-0,6 Нм
Многожильный кабель: удалите изоляцию, скрутите провода,
затем подсоедините кабель (или
используйте обжимку)
Одинарный провод: удалите изоляцию, затем
подсоедините провод
4. WIRING
Note:
When wiring DC supplies the "positive" cable should be con-
nected to the "+" terminal and the negative cable should be con-
nected to the "-" terminal. On no account should the power supply
terminals be connected to any other terminal on the unit. Revers-
ing the terminals will seriously damage the AL2-2TC-ADP expan-
sion module.
Under no circumstances should AC voltage be used as the AL2-
2TC-ADP expansion module will be seriously damaged.
Do not lay signal cabling near to high voltage power cables or
house them in the same trunking duct. Effects of noise or surge
induction may occur. Keep signal cables a safe of more than 100
mm (3.94") distance away from these power cables.
The AL2-2TC-ADP and
α2 Series main unit must use the same
power supply.
7mm(0.276") ±0.5mm(0.02")
26 -12 AWG
Temperature Rating: Min. 80ºC (176ºF)
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Hinweis:
Beim Anschluss der DC-Versorgungsspannung muss das „posi-
tive“ Kabel mit der Klemme „+“ und das „negative“ Kabel mit der
Klemme „-“ verbunden werden. Auf keinen Fall darf die Span-
nungsversorgung an eine andere Klemme des Moduls ange-
schlossen werden. Ein Vertauschen der Klemmen kann zu einer
schweren Beschädigung des AL2-2TC-ADP führen.
Der Anschluss einer AC-Spannungsquelle an das Erweiterungs-
modul AL2-2TC-ADP kann zu einer schweren Beschädigung des
Moduls führen.
Velegen Sie zur Vermeidung von Störungen die Signalleitungen
nicht in die Nähe von Leitungen, die hohe Ströme oder Spannun-
gen übertragen.
Signalleitungen dürfen auch nicht zusammen mit diesen Leitun-
gen im selben Kabelkanal verlegt werden. Der Mindestabstand
beträgt 100 mm.
Das AL2-2TC-ADP und die
α2-Steuerung müssen von derselben
Spannungsquelle versorgt werden.
Note:
Lors du raccordement de la tension d'alimentation CC, le câble
"positif" doit être relié avec la borne "+" et le câble "négatif" avec
la borne "-". En aucun cas, la tension d'alimentation doit être rac-
cordée à une autre borne du module. Une permutation des
bornes peut entraîner un grave endommagement de l'AL2-2TC-
ADP.
Le raccordement d'une source de tension CA sur le module
d'extension AL2-2TC-ADP peut entraîner un grave endommage-
ment du module.
Ne posez pas les lignes de signaux à proximité de lignes qui
transmettent des courants ou tensions élevés afin d'éviter des
perturbations. Les lignes de signaux ne doivent pas non plus être
posées dans un caniveau électrique commun. L'écart minimal est
de 100 mm.
L'AL2-2TC-ADP et le bloc logique
α2 doivent être alimentés par
la même source de tension.
Avvertenza:
Per la connessione della tensione CC di alimentazione il cavo
"positivo" deve essere collegato al morsetto "+" e quello "nega-
tivo" al morsetto "-". In nessun caso l´alimentazione di tensione
deve essere connessa ad un altro morsetto del modulo. Se si
confondono i morsetti si possono avere gravi danneggiamenti
dello AL2-2TC-ADP.
La connessione di una sorgente di tensione AC al modulo di
ampliamento AL2-2TC-ADP può provocare gravi danneggiamenti
al modulo.
Per evitare disturbi non posare i circuiti dei segnali vicino a linee o
circuiti che trasmettono correnti o tensioni alte. I circuiti dei
segnali non devono essere posati con tali linee/circuiti nello
stessa canala portacavi. La distanza minima fra queste linee deve
essere di minimo 100 mm.
Il modulo AL2-2TC-ADP ed il microcontrollore
α2 devono essere
alimentati dalla stessa sorgente di tensione.
Observación:
En la conexión de la tensión de alimentación CC debe conectarse
el cable "positivo" con el borne "+" y el cable "negativo" con el
borne "-". En ningún caso debe conectarse la alimentación de
tensión con otro borne del módulo. Un cambio de los bornes
puede causar graves daños en el AL2-2TC-ADP.
La conexión de una fuente de tensión AC en el módulo de ampli-
ación AL2-2TC-ADP puede causar graves daños en el módulo.
Para evitar perturbaciones de las líneas de señal, éstas no deben
tenderse en la cercanía de líneas que transfieren flujos o ten-
siones de alta intensidad. Las líneas de señal no deben tenderse
tampoco en conjunto con estas líneas en un mismo canal para
cables.
La distancia mínima es de 100 mm
.
El AL2-2TC-ADP y el control
α2 deben alimentarse con la misma
fuente de tensión.
Observera:
Vid anslutning av DC-försörjningsspänning måste den "positiva"
kabeln anslutas till klämma"+" och den "negativa" kabel till
klämma "-". Spänningsförsörjningen får på inga villkor anslutas till
en av modulens andra klämmor. En förväxling av klämmorna kan
leda till avsevärda skador på AL2-2TC-ADP.
En anslutning av en AC-spänningskälla till tillsatsmodul AL2-2TC-
ADP kan leda till avsevärda skador på modulen.
För att undvika störningar får signalledningarna inte läggas i
närheten av ledningar som överför stark ström eller spänningar.
Signalledningar får inte heller läggas i samma kabelkanal som
dessa ledningar. Minimiavståndet ska uppgå till 100 mm.
Spänningen för AL2-2TC-ADP och
α2-styrningen måste komma
från samma källa.
GER
FRE
ITL
ESP
SWE
Примечание:
При подключении к источнику питания постоянного тока «+»
источника питания следует присоединять к клемме «+», а «-»,
соответственно, к клемме «-».
Ни при каких условиях не следует присоединять источник питания
к каким-либо другим клеммам устройства. Обратное подключение
(«+» на «-») вызовет серьезные повреждения модуля расширения
AL2-2TC-ADP.
Ни при каких условиях не следует подключать модуль расширения
A
L2-2TC-ADP к источнику переменного тока, поскольку это
приведет к серьезным повреждениям данного устройства.
Не прокладывайте сигнальные кабели рядом с высоковольтными
силовыми кабелями, и не помещайте их в один кабельный канал
это может привести к появлению помех и импульсных наводок.
Безопасным расстоянием между этими кабелями является 100мм
и более.
Питание модуля A
L2-2TC-ADP и контроллера серии α2 должно
подаваться от одного источника.
Figure4.
EMC Caution:
Users may temporarily experience errors not exceeding +/- 10% of the
actual value when the AL2-2TC-ADP is used in excessive EMC fields.
Please refer to
α2 Hardware Manual for further details.
EMC-Vorsichtsmaßnahmen:
Wird das AL2-2TC-ADP in Bereichen mit starken elektromagnetischen
Störeinstrahlungen eingesetzt, können zeitweise Fehler auftreten, die +/-10
% des aktuellen Wertes überschreiten. Nähere Hinweise finden Sie in der
Hardware-Anleitung zur
α2-Steuerung.
Mesures CEM de précautions:
Si l'AL2-2TC-ADP est implanté dans des endroits avec de forts
rayonnements électromagnétiques perturbateurs, des erreurs pouvant
atteindre au maximum +/-10 % de la valeur actuelle peuvent
temporairement apparaître.
Misure precauzionali per le EMC:
Se si impiega il modulo AL2-2TC-ADP in zone con forti interferenze
elettromagnetiche di quando in quando possono verificarsi errori, che non
superano +/-10% del valore attuale. Maggiori dettagli si trovano nelle
istruzioni per l´hardware relative al microcontrollore
α2.
Medidas de precaución CEM:
Cuando se aplica el AL2-2TC-ADP en áreas con una fuerte radiación
perturbadora electromagnética, pueden presentarse temporalmente fallas
que no superan el +/-10% del valor actual. Mayores indicaciones se
encuentran en las instrucciones de hardware para el control
α2.
EMC-säkerhetsanvisningar:
När AL2-2TC-ADP används i områden med starka elektromagnetiska
störningsfält kan temporära fel uppstå, dessa får inte överstiga +/-10 % av
det aktuella värdet. För närmare information vänligen se
α2-styrenhetens
hårdvaramanual.
RUS
24V
DC
24+ 24- V1+ V1- V2+ V2-
+15V
3k 3k
L1+ L1- SLD L2+ L2- SLD
Grounding
resistance
100
or
less
K-type
Thermocouple
K-type
Thermocouple
+-(A)(B)12
AL2-14MR-D/
AL2-24MR-D
AL2-2TC-
ADP
Temprature
compensation
circuit
Grounding
resistance
100
or
less
Shielded
Shielded
0.5A
1.0A
ENG
GER
FRE
ITL
ESP
SWE
Предупреждение по электромагнитной
совместимости:
При работе модуля AL2-2TC-ADP в сильных электромагнитных полях
возможно появление ошибок, не превышающих +/- 10% фактического
значения величин. Для получения дальнейшей информации см.
Руководство по аппаратной части контроллера
α2.
5. PERFORMANCE SPECIFICATIONS
The AL2-2TC-ADP thermocouple analog sensor adaptor module (hereafter
called “AL2-2TC-ADP”) should be used to amplify thermocouple sensor
(K type) temperature input to 0 - 10V voltage analog signal for use in the
main unit. The main unit can only be a DC type
α
2 Series Controller
ver 2.0 or later. Refer to the
α2 Programming and Hardware manuals for
further details concerning the AL2-2TC-ADP.
Das Thermoelement-Adapter-Modul AL2-2TC-ADP wandelt die mit einem
Thermoelement erfasste Temperatur in eine Spannung von 0 bis 10 V um.
Es kann nur ein
α
2 -Hauptmodul mit Gleichspannungsversorgung ab
der Version 2.0 verwendet werden. Nähere Hinweise zur
Programmierung und zur Hardware finden Sie in den Handbüchern zur
α2-Steuerung.
Le module adaptateur de thermocouple AL2-2TC-ADP convertit la
température saisie avec un thermocouple en une tension de 0 à 10 V. Seul
un module principal
α
2 avec alimentation en tension continue de
version 2.0 ou supérieure peut être utilisé. Vous trouverez des plus
amples informations sur la programmation et sur le matériel dans les
manuels du bloc logique
α2.
Il modulo adattatore per il termoelemento AL2-2TC-ADP trasforma la
temperatura rilevata con un termoelemento in una tensione fra 0 e 10 V. Si
può usare solo un modulo principale
α
2 con alimentazione in CC a
partire dalla versione 2.0. Informazioni più dettagliate per la
programmazione e per l´hardware si trovano nei manuali relativi al
microcontrollore
α2.
El módulo adaptador para el termoelemento AL2-2TC-ADP transforma la
temperatura obtenida hacia una tensión de 0 a 10 V. Se puede utilizar
solamente un módulo principal
α
2 con alimentación de corriente
continua a partir de la versión 2.0. Mayor información acerca de la
programación y el hardware se encuentra en los manuales para el control
α2.
Termo-adapter-modul AL2-2PT-ADP omvandlar signalen från ett
termoelement till en spänning på 0 till 10 V
. Huvudmodulen skall vara av
α
2-typ med likströmsförsörjning från version 2.0 eller senare.
För närmare information om programmering och hårdvara se handböckerna
för
α
2-styrenheten.
Модуль адаптера AL2-2TC-ADP для термопар (далее называемый
«модуль AL2-2TC-ADP») предназначен для преобразования сигнала
термопар (К-типа) и получения аналогового сигнала в диапазоне 0–
10В, который используется в главном блоке. Главным блоком при
этом может являться только контроллер серии
α2 версии 2.0 или
более поздней, подключаемый к источнику постоянного тока. Для
получения дальнейшей информации по модулю AL2-2TC-ADP см.
Руководство по программному обеспечению контроллера
α2.
Table 2. Adjustment Standard
EC Directive EMC
EN61131-2:2007
EN60730-1:2011
Certification of UL/cUL File number: E95239
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Table 3. Analog Input Characteristics
Item Centigrade (°C) Fahrenheit (°F)
ENG Input Specification
Thermocouple K type, JIS 1602-1995 (IEC
584-1 1977, IEC 584-2 1982), Isolated type
GER Thermoelement-
Eingang
Isoliertes Thermoelement Typ K (IEC 584-1
1977, IEC 584-2 1982)
FRE Entrée du
thermocouple
Thermocouple isolé de type K (IEC 584-1
1977, IEC 584-2 1982)
ITL Ingresso del
termoelemento
Termoelemento isolato tipo K (IEC 584-1 1977;
IEC 584-2 1982)
ESP Entrada del
termoelemento
Termoelemento aislado del tipo K (IEC 584-1
1977, IEC 584-2 1982)
SWE Termoelement-ingång
Isolierat termoelement typ K (IEC 584-1 1977,
IEC 584-2 1982)
RUS Входные
характеристики
Термопара К-типа, JIS 1602-1995 (IEC 584-1
1977, IEC 584-2 1982), изолированный тип
ENG Compensated Range
-50°C - 450°C-58°F - 842°F
GER Kompensierter Bereich
FRE Plage compensée
ITL Intervallo di lettura
ESP Rango compensado
SWE Kompenserat område
RUS Компенсируемый
диапазон
ENG Overall accuracy
±2.0% (range of all
temperatures) and
±1.5% (at 25°C)
±2.0% (range of all
temperatures) and
±1.5% (at 77°F)
GER Genauigkeit
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 25 °C
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 77 °F
FRE Précision
±2,0 % (pour toutes
les températures) et
± 1,5 % à 25 °C
±2,0 % (pour toutes
les températures) et
± 1,5 % à 77°F
ITL Precisione
±2,0% (per tutte le
temperature) e
± 1,5% a 25 °C
±2,0% (per tutte le
temperature) e
± 1,5% a 77°F
ESP Precisión
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 25 °C
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 77°F
SWE Noggrannhet
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 25 °C
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 77°F
RUS Об
щая погрешность
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 25°C)
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 77°F)
ENG Resolution
1°C
GER Auflösung
FRE Résolution
ITL Risoluzione
ESP Resolución
SWE Upplösning
RUS Разрешение
ENG Conversion Speed
20.5ms
GER Wandlungszeit
FRE Temps de conversion
ITL Tempo di
commutazione
ESP Duración de conversión
SWE Omvandlingstid
RUS Скорость
преобразования
ENG Isolation
No isolation between channels (input/output)
and power
GER Isolation
Keine Isolation zwischen den Kanälen (Ein-
oder Ausgang) und der Stromversorgung.
Note:
Please refer to the α 2 Programming and Hardware Manual for
further details concerning Gain and Offset adjustment for the AL2-
2TC-ADP module.
Hinweise zur Offset- und Verstärkungseinstellung beim AL2-2TC-
ADP finden Sie in den Programmier- und Hardware-Handbüchern zur
α2-Steuerung.
Vous trouverez des indications sur le réglage de l'offset et du gain pour
l'AL2-
2TC
-ADP dans les manuels de programmation et du matériel du
bloc logique
α
2.
Istruzioni per la regolazione di offset e guadagno per AL2-
2TC
-
ADP si trovano nei manuali di programmazione e dell´hardware relativi
al microcontrollore
α
2.
Mayor información acerca de la regulación de la desviación y de la
ganancia del AL2-2TC-ADP se encuentra en los manuales de
programación y hardware para el control
α2.
För närmare information om inställning av offset och förstärkning i
AL2-2TC-ADP se programmerings- och hårdvarahandböcker för
α2-
styrningen.
Для получения дальнейшей информации по регулировке
величин смещения и усиления модуля AL2-2TC-ADP см.
Руководстве по программированию контроллера серии
α2.
6. GENERAL SPECIFICATIONS
Table 4.
FRE Isolement
Aucune isolation entre les canaux (entrée ou
sortie) et l'alimentation en courant.
ITL Isolamento
Nessun isolamento fra I canali (enrata o
uscita) e alimentazione di corrente.
ESP Aislamiento
No existe aislación entre los canales (entrada
o salida) y la alimentación de corriente.
SWE Isolationskrets
Ingen isolering mellan kanalerna (in- och
utgång) och strömförsörjningen.
RUS Развязка
Развязка между каналами (вход/выход) и
цепью питания отсутствует
ENG Conversion
Characteristics
(Centigrade (°C))
(Fahrenheit (°F))
GER Wandlerkennlinie
FRE Caractéristique de
conversion
ITL Curva digitale
analogica
ESP Característica de
conversión
SWE Omvandlings-
karakteristik
RUS Характеристики
преобразования
Item Specification
ENG
Power Supply,
Max. Power Consumption
24V DC +20%, -15%, 1.0W
GER Spannungsversorgung
FRE Alimentation en courant
ITL Tensione alimentazione
ESP Alimentación en tensión
SWE Strömförsörjning
RUS
Источник питания,
максимальное
потребление
электроэнергии
Item Centigrade (°C) Fahrenheit (°F)
Digital
+450
-50
+450°C
(K-Type)
Temperature
+470
+470°C
-50°C
-70°C
-70
Digital
+8420
-580
+842°F
(K-Type)
Temperature
+8780
+878°F
-58°F
-94°F
-940
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG Operating Temperature
(-25) - 55°C / (-13) - 131°F
GER Betriebstemperatur
FRE
Température de
fonctionnement
ITL Temperatura di esercizio
ESP Temperatura de servizio
SWE Drifttemperatur
RUS Рабочая температура
ENG Storage Temperature
(-30) - 70°C / (-22) - 158°F
GER Lagertemperatur
FRE Température de stockage
ITL Temperatura di stoccaggio
ESP
Temperatura de
almacenamiento
SWE Förvaringstemperatur
RUS Температура хранения
ENG Humidity
35 - 85% Relative Humidity,
no condensation
GER Luftfeuchtigkeit
35 bis 85 % relative Luftfeuchtigkeit,
keine Kondensation
FRE Humidité
Humidité relative 35 – 85 %,
sans condensation
ITL Umidita
Umidita relativa 35-85%,
senza condensa
ESP Humedad
Humedad relativa 35-85%,
sin condensación
SWE Luftfuktighet
35–85 % relativ luftfuktighet,
icke kondenserande
RUS Влажность
Относительная влажность 35 - 85%,
без конденсата
ENG
Vibration Resistance
- DIN Rail Mounting
Conforms to IEC 68-2-6; 10-57Hz:
0.075mm Constant Amplitude
57-150Hz:9.8m/s
2
Acceleration. Sweep
Count for X, Y, and Z: 10 times (80 min-
utes in each direction
)
GER
Vibrationsfestigkeit
DIN-Schienen-Montage
Entspricht IEC 68-2-6; 10 – 57 Hz:
0,075 mm konstante Amplitude
57 – 150 Hz: 9,8 m/s
2
Beschleunigung.
Ablenkzyklus für X, Y, Z: 10 x (80 min. in
all 3 Richtungen)
FRE
Résistance aux vibrations
Montage sur rail DIN
Selon IEC 68-2-6; 10-57 Hz: 0,075 mm
amplitude constante
57-150 Hz: 9,8 m/s
2
accélération.
Nombre de balayages pour X,Y,Z: 10
fois (80 min. dans les 3 directions d’axe)
ITL
Resistenza vibrazioni
Montaggio su supporto DIN
Conforme alla normativa IEC 68-2-6;
10-57 Hz: 0,075 mm ampiezza
costante, 57-150 Hz: 9,8 m/s
2
accelerazione. Conteggio sweep per
X,Y,Z: 10 volte (80 min. in ogni
direzione)
ESP
Resistencia a las vibraciones
Montaje en raíl DIN
Conforme con IEC 68-2-6; 10-57 Hz:
0,075 mm amplitud constante, 57-150
Hz: 9,8 m/s
2
acceleración.
Conteo de barrido para X,Y,Z: 10 veces
(80 min. en cada dirección)
SWE
Vibrationstålighet
– montering på DIN-skena
Uppfyller IEC 68-2-6,10–57; Hz: 0,075
mm konstant amplitud, 57–150 Hz: 9,8
m/s
2
acceleration.
Svep i X, Y, Z: 10 gånger (80 minuter i
vardera riktningen)
RUS
Вибрационная
устойчивость при монтаже
на рельс DIN
Соответствует стандарту IEC 68-2-6;
10-57Гц: постоянная амплитуда
0,075мм
57-150 Гц: Ускорение 9.8м/с
2,
,
Количество размахов по всем трем
осям – 10 раз (80 минут в каждом
направлении).
ENG Shock Resistance
Conforms to IEC 68-2-27: 147m/s
2
Acceleration, Action Time: 11ms 3 times
in each direction X, Y and Z
GER Stoßfestigkeit
Entspricht IEC 68-2-27: 147m/s
2
Beschleunigung für 11 ms, 3 mal in alle
3 Richtungen X, Y und Z
Item Specification
FRE Résistance aux chocs
Selon IEC 68-2-27: 147m/s
2
accélération, temps d'action: 11 ms, 3
fois dans les 3 directions d’axe X,Y et Z
ITL Resistenza agli urti
Conforme alla normativa IEC 68-2-
27:147m/s
2
accelerazione, tempo di
azione: 11 ms, 3 volte in ogni direzione
X,Y e Z
ESP Resistencia al choque
Conforme con IEC 68-2-27: 147m/s
2
acceleración, tiempo de acción: 11 ms,
3 veces en cada dirección X,Y y Z
SWE Stöttålighet
Uppfyller IEC 68-2-27:147 m/s
2
acceleration under 11 ms, 3 gånger
vardera i riktningarna X, Y och Z
RUS Ударная устойчивость
Соответствует стандарту IEC 68-2-27:
Ускорение 147м/с
2
, длительность
воздействия: 11 мс 3 раза по каждой
оси.
ENG Noise Immunity
1000 Vpp 1µs, 30 - 100 Hz, tested by a
noise simulator
GER Störspannungsfestigkeit
1000 Vpp für 1µs, 30 - 100 Hz, getestet
mit Störspannungssimulator
FRE
Résistance aux tensions
parasites
1000Vpp, 1 microseconde, 30 - 100 Hz,
testé par simulateur de bruits
ITL Immunità al rumore
1000Vpp, 1 microsecondi, 30 - 100 Hz,
collaudato mediante simulatore di
rumore
ESP Inmunidad al ruido
1000Vpp, 1 microsegundo, 30 - 100 Hz,
probado por simulador de ruidos
SWE Brusokänslighet
1000 Vpp, 1 µs, 30–100 Hz, testat med
brussimulator
RUS Помехоустойчивость
1000 Впп 1мкс, 30 - 100 Гц,
протестировано с помощью
имитатора шумовых помех
ENG Dielectric Withstand Voltage
500V AC>1min per EN60730-1
between all terminals and the DIN43880
control box or equivalent.
GER Spannungsfestigkeit
500 V > 1 min nach EN60730-1
zwischen allen Klemmen und dem
Steuerkasten (DIN 43880) oder
Ähnlichem
FRE Rigidité diélectrique
500V CA > 1 min par EN60730-1 entre
toutes les bornes et le coffret (DIN
43880) et d’autres
ITL Rigidità dielettrica
500V AC > 1 min. come da norma
EN60730-1 tra tutti i morsetti e l’unità di
controllo DIN 43880 o equivalente
ESP
Resistencia a tensiones
eléctricas
500V CA > 1 min por EN60730-1 entre
todos los terminales y la caja de control
DIN 43880 ó sus equivalentes
SWE Genomslagsspänning
500 V >1 min enligt EN60730-1 mellan
alla plintar och DIN 43880
styrenhetsbox eller motsvarande
RUS
Напряжение
диэлектрической прочности
Напряжение ~500В, более 1 минуты,
по стандартуr EN60730-1,
напряжение ме
жду всеми клеммами
и шкафом управления по стандарту
DIN43880 или между
эквивалентными точками
ENG Insulation Resistance
7 M, 500V DC EN60730-1 between all
terminals and the DIN43880 distribution
box or equivalent.
GER Isolationswiderstand
7 M, 500 V DC nach EN60730-1
zwischen allen Klemmen und dem
Schaltschrank nach DIN 43880
FRE Résistance d’isolement
7 M, 500 V CC selon EN60730-1 entre
toutes les bornes et l'armoire électrique
selon DIN 43880
ITL Resistenza di isolamento
7 M, 500 V CC conf. EN60730-1 fra
tutti i morseti ed il quadro elettrico ad
armadio conf. DIN 43880
ESP Resistencia de aislamiento
7 M, 500 V CC según EN60730-1
entre todos los bornes y el armario de
distribución según DIN 43880
SWE Isolationsresistans
7 M, 500 V DC enligt EN60730-1
mellan alla klämmor och elskåpet enligt
DIN 43880.
Item Specification
RUS Сопротивление изоляции
7 MОм, при напряжении постоянного
тока 500В по стандарту EN60730-1,
напряжение между всеми клеммами
и распределительной коробкой или
между эквивалентными точками.
ENG Operation Ambience To be free of corrosive gases
GER Umgebungsbedingungen Frei von aggressiven Gasen
FRE Conditions ambiantes Sans gaz agressif
ITL Condizioni ambientali Ambiente privo di gas aggressivi
ESP Condiciones de entorno Libre de gases agresivos
SWE Driftmiljö Fri från korrosiva gaser
RUS
Рабочая окружающая
среда
Не должна содержать агрессивных
газов
Item Specification
1RWH7KLVV\PEROPDUNLVIRU&KLQDRQO\
ਜ਼ᴹᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘
ǂ
ᵜӗ૱ѝᡰਜ਼ᴹⲴᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘૱ྲл㺘
ᡰ⽪DŽ
ӝ૷ѣᴿᇩ⢟䍞Ⲻ੃〦਀੡䠅
ᵜ㺘Ṭ׍ᦞ6-7Ⲵ㿴ᇊ㕆ࡦDŽ
สҾѝഭḷ߶⌅Ⲵ৲㘳㿴Ṭ*%7
ƻ
㺘⽪䈕ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴਜ਼䟿൷൘*%7
㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
h㺘⽪䈕ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴਜ਼䟿䎵ࠪ*%7
 㿴ᇊⲴ䲀䟿㾱≲DŽ
䜞Ԭ੃〦
ᴿᇩ⢟䍞
3E
+J
䭿
&G
ޣԭ䬢
&U9,
ཐ⓪㚊㤥
3%%
ཐ⓪ӂ㤥䟐
3%'(
ཆ༣
ঠࡧสᶯ
㔗⭥ಘ
⭥㔶
ƻƻ
ƻƻ ƻ ƻ ƻ
ƻƻ ƻ ƻ
h
ƻh ƻ ƻ ƻƻ
ƻƻ ƻ ƻ ƻh
ɇ⭫ಞ⭫ᆆӝ૷ᴿᇩ⢟䍞䲆࡬ֵ⭞ḽ䇼㾷≸ɈⲺ㺞⽰ᯯᕅ
Manual Number : JY997D09501
Manual Revision : H
Date : June 2018
JY997D09501H
Effective June 2018
Specifications are subject to
change without notice.
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Hinweis:
Beim Anschluss der DC-Versorgungsspannung muss das „posi-
tive“ Kabel mit der Klemme „+“ und das „negative“ Kabel mit der
Klemme „-“ verbunden werden. Auf keinen Fall darf die Span-
nungsversorgung an eine andere Klemme des Moduls ange-
schlossen werden. Ein Vertauschen der Klemmen kann zu einer
schweren Beschädigung des AL2-2TC-ADP führen.
Der Anschluss einer AC-Spannungsquelle an das Erweiterungs-
modul AL2-2TC-ADP kann zu einer schweren Beschädigung des
Moduls führen.
Velegen Sie zur Vermeidung von Störungen die Signalleitungen
nicht in die Nähe von Leitungen, die hohe Ströme oder Spannun-
gen übertragen.
Signalleitungen dürfen auch nicht zusammen mit diesen Leitun-
gen im selben Kabelkanal verlegt werden. Der Mindestabstand
beträgt 100 mm.
Das AL2-2TC-ADP und die
α2-Steuerung müssen von derselben
Spannungsquelle versorgt werden.
Note:
Lors du raccordement de la tension d'alimentation CC, le câble
"positif" doit être relié avec la borne "+" et le câble "négatif" avec
la borne "-". En aucun cas, la tension d'alimentation doit être rac-
cordée à une autre borne du module. Une permutation des
bornes peut entraîner un grave endommagement de l'AL2-2TC-
ADP.
Le raccordement d'une source de tension CA sur le module
d'extension AL2-2TC-ADP peut entraîner un grave endommage-
ment du module.
Ne posez pas les lignes de signaux à proximité de lignes qui
transmettent des courants ou tensions élevés afin d'éviter des
perturbations. Les lignes de signaux ne doivent pas non plus être
posées dans un caniveau électrique commun. L'écart minimal est
de 100 mm.
L'AL2-2TC-ADP et le bloc logique
α2 doivent être alimentés par
la même source de tension.
Avvertenza:
Per la connessione della tensione CC di alimentazione il cavo
"positivo" deve essere collegato al morsetto "+" e quello "nega-
tivo" al morsetto "-". In nessun caso l´alimentazione di tensione
deve essere connessa ad un altro morsetto del modulo. Se si
confondono i morsetti si possono avere gravi danneggiamenti
dello AL2-2TC-ADP.
La connessione di una sorgente di tensione AC al modulo di
ampliamento AL2-2TC-ADP può provocare gravi danneggiamenti
al modulo.
Per evitare disturbi non posare i circuiti dei segnali vicino a linee o
circuiti che trasmettono correnti o tensioni alte. I circuiti dei
segnali non devono essere posati con tali linee/circuiti nello
stessa canala portacavi. La distanza minima fra queste linee deve
essere di minimo 100 mm.
Il modulo AL2-2TC-ADP ed il microcontrollore
α2 devono essere
alimentati dalla stessa sorgente di tensione.
Observación:
En la conexión de la tensión de alimentación CC debe conectarse
el cable "positivo" con el borne "+" y el cable "negativo" con el
borne "-". En ningún caso debe conectarse la alimentación de
tensión con otro borne del módulo. Un cambio de los bornes
puede causar graves daños en el AL2-2TC-ADP.
La conexión de una fuente de tensión AC en el módulo de ampli-
ación AL2-2TC-ADP puede causar graves daños en el módulo.
Para evitar perturbaciones de las líneas de señal, éstas no deben
tenderse en la cercanía de líneas que transfieren flujos o ten-
siones de alta intensidad. Las líneas de señal no deben tenderse
tampoco en conjunto con estas líneas en un mismo canal para
cables.
La distancia mínima es de 100 mm
.
El AL2-2TC-ADP y el control
α2 deben alimentarse con la misma
fuente de tensión.
Observera:
Vid anslutning av DC-försörjningsspänning måste den "positiva"
kabeln anslutas till klämma"+" och den "negativa" kabel till
klämma "-". Spänningsförsörjningen får på inga villkor anslutas till
en av modulens andra klämmor. En förväxling av klämmorna kan
leda till avsevärda skador på AL2-2TC-ADP.
En anslutning av en AC-spänningskälla till tillsatsmodul AL2-2TC-
ADP kan leda till avsevärda skador på modulen.
För att undvika störningar får signalledningarna inte läggas i
närheten av ledningar som överför stark ström eller spänningar.
Signalledningar får inte heller läggas i samma kabelkanal som
dessa ledningar. Minimiavståndet ska uppgå till 100 mm.
Spänningen för AL2-2TC-ADP och
α2-styrningen måste komma
från samma källa.
GER
FRE
ITL
ESP
SWE
Примечание:
При подключении к источнику питания постоянного тока «+»
источника питания следует присоединять к клемме «+», а «-»,
соответственно, к клемме «-».
Ни при каких условиях не следует присоединять источник питания
к каким-либо другим клеммам устройства. Обратное подключение
(«+» на «-») вызовет серьезные повреждения модуля расширения
AL2-2TC-ADP.
Ни при каких условиях не следует подключать модуль расширения
A
L2-2TC-ADP к источнику переменного тока, поскольку это
приведет к серьезным повреждениям данного устройства.
Не прокладывайте сигнальные кабели рядом с высоковольтными
силовыми кабелями, и не помещайте их в один кабельный канал
это может привести к появлению помех и импульсных наводок.
Безопасным расстоянием между этими кабелями является 100мм
и более.
Питание модуля A
L2-2TC-ADP и контроллера серии α2 должно
подаваться от одного источника.
Figure4.
EMC Caution:
Users may temporarily experience errors not exceeding +/- 10% of the
actual value when the AL2-2TC-ADP is used in excessive EMC fields.
Please refer to
α2 Hardware Manual for further details.
EMC-Vorsichtsmaßnahmen:
Wird das AL2-2TC-ADP in Bereichen mit starken elektromagnetischen
Störeinstrahlungen eingesetzt, können zeitweise Fehler auftreten, die +/-10
% des aktuellen Wertes überschreiten. Nähere Hinweise finden Sie in der
Hardware-Anleitung zur
α2-Steuerung.
Mesures CEM de précautions:
Si l'AL2-2TC-ADP est implanté dans des endroits avec de forts
rayonnements électromagnétiques perturbateurs, des erreurs pouvant
atteindre au maximum +/-10 % de la valeur actuelle peuvent
temporairement apparaître.
Misure precauzionali per le EMC:
Se si impiega il modulo AL2-2TC-ADP in zone con forti interferenze
elettromagnetiche di quando in quando possono verificarsi errori, che non
superano +/-10% del valore attuale. Maggiori dettagli si trovano nelle
istruzioni per l´hardware relative al microcontrollore
α2.
Medidas de precaución CEM:
Cuando se aplica el AL2-2TC-ADP en áreas con una fuerte radiación
perturbadora electromagnética, pueden presentarse temporalmente fallas
que no superan el +/-10% del valor actual. Mayores indicaciones se
encuentran en las instrucciones de hardware para el control
α2.
EMC-säkerhetsanvisningar:
När AL2-2TC-ADP används i områden med starka elektromagnetiska
störningsfält kan temporära fel uppstå, dessa får inte överstiga +/-10 % av
det aktuella värdet. För närmare information vänligen se
α2-styrenhetens
hårdvaramanual.
RUS
24V
DC
24+ 24- V1+ V1- V2+ V2-
+15V
3k 3k
L1+ L1- SLD L2+ L2- SLD
Grounding
resistance
100
or
less
K-type
Thermocouple
K-type
Thermocouple
+-(A)(B)12
AL2-14MR-D/
AL2-24MR-D
AL2-2TC-
ADP
Temprature
compensation
circuit
Grounding
resistance
100
or
less
Shielded
Shielded
0.5A
1.0A
ENG
GER
FRE
ITL
ESP
SWE
Предупреждение по электромагнитной
совместимости:
При работе модуля AL2-2TC-ADP в сильных электромагнитных полях
возможно появление ошибок, не превышающих +/- 10% фактического
значения величин. Для получения дальнейшей информации см.
Руководство по аппаратной части контроллера
α2.
5. PERFORMANCE SPECIFICATIONS
The AL2-2TC-ADP thermocouple analog sensor adaptor module (hereafter
called “AL2-2TC-ADP”) should be used to amplify thermocouple sensor
(K type) temperature input to 0 - 10V voltage analog signal for use in the
main unit. The main unit can only be a DC type
α
2 Series Controller
ver 2.0 or later. Refer to the
α2 Programming and Hardware manuals for
further details concerning the AL2-2TC-ADP.
Das Thermoelement-Adapter-Modul AL2-2TC-ADP wandelt die mit einem
Thermoelement erfasste Temperatur in eine Spannung von 0 bis 10 V um.
Es kann nur ein
α
2 -Hauptmodul mit Gleichspannungsversorgung ab
der Version 2.0 verwendet werden. Nähere Hinweise zur
Programmierung und zur Hardware finden Sie in den Handbüchern zur
α2-Steuerung.
Le module adaptateur de thermocouple AL2-2TC-ADP convertit la
température saisie avec un thermocouple en une tension de 0 à 10 V. Seul
un module principal
α
2 avec alimentation en tension continue de
version 2.0 ou supérieure peut être utilisé. Vous trouverez des plus
amples informations sur la programmation et sur le matériel dans les
manuels du bloc logique
α2.
Il modulo adattatore per il termoelemento AL2-2TC-ADP trasforma la
temperatura rilevata con un termoelemento in una tensione fra 0 e 10 V. Si
può usare solo un modulo principale
α
2 con alimentazione in CC a
partire dalla versione 2.0. Informazioni più dettagliate per la
programmazione e per l´hardware si trovano nei manuali relativi al
microcontrollore
α2.
El módulo adaptador para el termoelemento AL2-2TC-ADP transforma la
temperatura obtenida hacia una tensión de 0 a 10 V. Se puede utilizar
solamente un módulo principal
α
2 con alimentación de corriente
continua a partir de la versión 2.0. Mayor información acerca de la
programación y el hardware se encuentra en los manuales para el control
α2.
Termo-adapter-modul AL2-2PT-ADP omvandlar signalen från ett
termoelement till en spänning på 0 till 10 V
. Huvudmodulen skall vara av
α
2-typ med likströmsförsörjning från version 2.0 eller senare.
För närmare information om programmering och hårdvara se handböckerna
för
α
2-styrenheten.
Модуль адаптера AL2-2TC-ADP для термопар (далее называемый
«модуль AL2-2TC-ADP») предназначен для преобразования сигнала
термопар (К-типа) и получения аналогового сигнала в диапазоне 0–
10В, который используется в главном блоке. Главным блоком при
этом может являться только контроллер серии
α2 версии 2.0 или
более поздней, подключаемый к источнику постоянного тока. Для
получения дальнейшей информации по модулю AL2-2TC-ADP см.
Руководство по программному обеспечению контроллера
α2.
Table 2. Adjustment Standard
EC Directive EMC
EN61131-2:2007
EN60730-1:2011
Certification of UL/cUL File number: E95239
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Table 3. Analog Input Characteristics
Item Centigrade (°C) Fahrenheit (°F)
ENG Input Specification
Thermocouple K type, JIS 1602-1995 (IEC
584-1 1977, IEC 584-2 1982), Isolated type
GER Thermoelement-
Eingang
Isoliertes Thermoelement Typ K (IEC 584-1
1977, IEC 584-2 1982)
FRE Entrée du
thermocouple
Thermocouple isolé de type K (IEC 584-1
1977, IEC 584-2 1982)
ITL Ingresso del
termoelemento
Termoelemento isolato tipo K (IEC 584-1 1977;
IEC 584-2 1982)
ESP Entrada del
termoelemento
Termoelemento aislado del tipo K (IEC 584-1
1977, IEC 584-2 1982)
SWE Termoelement-ingång
Isolierat termoelement typ K (IEC 584-1 1977,
IEC 584-2 1982)
RUS Входные
характеристики
Термопара К-типа, JIS 1602-1995 (IEC 584-1
1977, IEC 584-2 1982), изолированный тип
ENG Compensated Range
-50°C - 450°C-58°F - 842°F
GER Kompensierter Bereich
FRE Plage compensée
ITL Intervallo di lettura
ESP Rango compensado
SWE Kompenserat område
RUS Компенсируемый
диапазон
ENG Overall accuracy
±2.0% (range of all
temperatures) and
±1.5% (at 25°C)
±2.0% (range of all
temperatures) and
±1.5% (at 77°F)
GER Genauigkeit
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 25 °C
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 77 °F
FRE Précision
±2,0 % (pour toutes
les températures) et
± 1,5 % à 25 °C
±2,0 % (pour toutes
les températures) et
± 1,5 % à 77°F
ITL Precisione
±2,0% (per tutte le
temperature) e
± 1,5% a 25 °C
±2,0% (per tutte le
temperature) e
± 1,5% a 77°F
ESP Precisión
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 25 °C
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 77°F
SWE Noggrannhet
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 25 °C
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 77°F
RUS Об
щая погрешность
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 25°C)
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 77°F)
ENG Resolution
1°C
GER Auflösung
FRE Résolution
ITL Risoluzione
ESP Resolución
SWE Upplösning
RUS Разрешение
ENG Conversion Speed
20.5ms
GER Wandlungszeit
FRE Temps de conversion
ITL Tempo di
commutazione
ESP Duración de conversión
SWE Omvandlingstid
RUS Скорость
преобразования
ENG Isolation
No isolation between channels (input/output)
and power
GER Isolation
Keine Isolation zwischen den Kanälen (Ein-
oder Ausgang) und der Stromversorgung.
Note:
Please refer to the α 2 Programming and Hardware Manual for
further details concerning Gain and Offset adjustment for the AL2-
2TC-ADP module.
Hinweise zur Offset- und Verstärkungseinstellung beim AL2-2TC-
ADP finden Sie in den Programmier- und Hardware-Handbüchern zur
α2-Steuerung.
Vous trouverez des indications sur le réglage de l'offset et du gain pour
l'AL2-
2TC
-ADP dans les manuels de programmation et du matériel du
bloc logique
α
2.
Istruzioni per la regolazione di offset e guadagno per AL2-
2TC
-
ADP si trovano nei manuali di programmazione e dell´hardware relativi
al microcontrollore
α
2.
Mayor información acerca de la regulación de la desviación y de la
ganancia del AL2-2TC-ADP se encuentra en los manuales de
programación y hardware para el control
α2.
För närmare information om inställning av offset och förstärkning i
AL2-2TC-ADP se programmerings- och hårdvarahandböcker för
α2-
styrningen.
Для получения дальнейшей информации по регулировке
величин смещения и усиления модуля AL2-2TC-ADP см.
Руководстве по программированию контроллера серии
α2.
6. GENERAL SPECIFICATIONS
Table 4.
FRE Isolement
Aucune isolation entre les canaux (entrée ou
sortie) et l'alimentation en courant.
ITL Isolamento
Nessun isolamento fra I canali (enrata o
uscita) e alimentazione di corrente.
ESP Aislamiento
No existe aislación entre los canales (entrada
o salida) y la alimentación de corriente.
SWE Isolationskrets
Ingen isolering mellan kanalerna (in- och
utgång) och strömförsörjningen.
RUS Развязка
Развязка между каналами (вход/выход) и
цепью питания отсутствует
ENG Conversion
Characteristics
(Centigrade (°C))
(Fahrenheit (°F))
GER Wandlerkennlinie
FRE Caractéristique de
conversion
ITL Curva digitale
analogica
ESP Característica de
conversión
SWE Omvandlings-
karakteristik
RUS Характеристики
преобразования
Item Specification
ENG
Power Supply,
Max. Power Consumption
24V DC +20%, -15%, 1.0W
GER Spannungsversorgung
FRE Alimentation en courant
ITL Tensione alimentazione
ESP Alimentación en tensión
SWE Strömförsörjning
RUS
Источник питания,
максимальное
потребление
электроэнергии
Item Centigrade (°C) Fahrenheit (°F)
Digital
+450
-50
+450°C
(K-Type)
Temperature
+470
+470°C
-50°C
-70°C
-70
Digital
+8420
-580
+842°F
(K-Type)
Temperature
+8780
+878°F
-58°F
-94°F
-940
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG Operating Temperature
(-25) - 55°C / (-13) - 131°F
GER Betriebstemperatur
FRE
Température de
fonctionnement
ITL Temperatura di esercizio
ESP Temperatura de servizio
SWE Drifttemperatur
RUS Рабочая температура
ENG Storage Temperature
(-30) - 70°C / (-22) - 158°F
GER Lagertemperatur
FRE Température de stockage
ITL Temperatura di stoccaggio
ESP
Temperatura de
almacenamiento
SWE Förvaringstemperatur
RUS Температура хранения
ENG Humidity
35 - 85% Relative Humidity,
no condensation
GER Luftfeuchtigkeit
35 bis 85 % relative Luftfeuchtigkeit,
keine Kondensation
FRE Humidité
Humidité relative 35 – 85 %,
sans condensation
ITL Umidita
Umidita relativa 35-85%,
senza condensa
ESP Humedad
Humedad relativa 35-85%,
sin condensación
SWE Luftfuktighet
35–85 % relativ luftfuktighet,
icke kondenserande
RUS Влажность
Относительная влажность 35 - 85%,
без конденсата
ENG
Vibration Resistance
- DIN Rail Mounting
Conforms to IEC 68-2-6; 10-57Hz:
0.075mm Constant Amplitude
57-150Hz:9.8m/s
2
Acceleration. Sweep
Count for X, Y, and Z: 10 times (80 min-
utes in each direction
)
GER
Vibrationsfestigkeit
DIN-Schienen-Montage
Entspricht IEC 68-2-6; 10 – 57 Hz:
0,075 mm konstante Amplitude
57 – 150 Hz: 9,8 m/s
2
Beschleunigung.
Ablenkzyklus für X, Y, Z: 10 x (80 min. in
all 3 Richtungen)
FRE
Résistance aux vibrations
Montage sur rail DIN
Selon IEC 68-2-6; 10-57 Hz: 0,075 mm
amplitude constante
57-150 Hz: 9,8 m/s
2
accélération.
Nombre de balayages pour X,Y,Z: 10
fois (80 min. dans les 3 directions d’axe)
ITL
Resistenza vibrazioni
Montaggio su supporto DIN
Conforme alla normativa IEC 68-2-6;
10-57 Hz: 0,075 mm ampiezza
costante, 57-150 Hz: 9,8 m/s
2
accelerazione. Conteggio sweep per
X,Y,Z: 10 volte (80 min. in ogni
direzione)
ESP
Resistencia a las vibraciones
Montaje en raíl DIN
Conforme con IEC 68-2-6; 10-57 Hz:
0,075 mm amplitud constante, 57-150
Hz: 9,8 m/s
2
acceleración.
Conteo de barrido para X,Y,Z: 10 veces
(80 min. en cada dirección)
SWE
Vibrationstålighet
– montering på DIN-skena
Uppfyller IEC 68-2-6,10–57; Hz: 0,075
mm konstant amplitud, 57–150 Hz: 9,8
m/s
2
acceleration.
Svep i X, Y, Z: 10 gånger (80 minuter i
vardera riktningen)
RUS
Вибрационная
устойчивость при монтаже
на рельс DIN
Соответствует стандарту IEC 68-2-6;
10-57Гц: постоянная амплитуда
0,075мм
57-150 Гц: Ускорение 9.8м/с
2,
,
Количество размахов по всем трем
осям – 10 раз (80 минут в каждом
направлении).
ENG Shock Resistance
Conforms to IEC 68-2-27: 147m/s
2
Acceleration, Action Time: 11ms 3 times
in each direction X, Y and Z
GER Stoßfestigkeit
Entspricht IEC 68-2-27: 147m/s
2
Beschleunigung für 11 ms, 3 mal in alle
3 Richtungen X, Y und Z
Item Specification
FRE Résistance aux chocs
Selon IEC 68-2-27: 147m/s
2
accélération, temps d'action: 11 ms, 3
fois dans les 3 directions d’axe X,Y et Z
ITL Resistenza agli urti
Conforme alla normativa IEC 68-2-
27:147m/s
2
accelerazione, tempo di
azione: 11 ms, 3 volte in ogni direzione
X,Y e Z
ESP Resistencia al choque
Conforme con IEC 68-2-27: 147m/s
2
acceleración, tiempo de acción: 11 ms,
3 veces en cada dirección X,Y y Z
SWE Stöttålighet
Uppfyller IEC 68-2-27:147 m/s
2
acceleration under 11 ms, 3 gånger
vardera i riktningarna X, Y och Z
RUS Ударная устойчивость
Соответствует стандарту IEC 68-2-27:
Ускорение 147м/с
2
, длительность
воздействия: 11 мс 3 раза по каждой
оси.
ENG Noise Immunity
1000 Vpp 1µs, 30 - 100 Hz, tested by a
noise simulator
GER Störspannungsfestigkeit
1000 Vpp für 1µs, 30 - 100 Hz, getestet
mit Störspannungssimulator
FRE
Résistance aux tensions
parasites
1000Vpp, 1 microseconde, 30 - 100 Hz,
testé par simulateur de bruits
ITL Immunità al rumore
1000Vpp, 1 microsecondi, 30 - 100 Hz,
collaudato mediante simulatore di
rumore
ESP Inmunidad al ruido
1000Vpp, 1 microsegundo, 30 - 100 Hz,
probado por simulador de ruidos
SWE Brusokänslighet
1000 Vpp, 1 µs, 30–100 Hz, testat med
brussimulator
RUS Помехоустойчивость
1000 Впп 1мкс, 30 - 100 Гц,
протестировано с помощью
имитатора шумовых помех
ENG Dielectric Withstand Voltage
500V AC>1min per EN60730-1
between all terminals and the DIN43880
control box or equivalent.
GER Spannungsfestigkeit
500 V > 1 min nach EN60730-1
zwischen allen Klemmen und dem
Steuerkasten (DIN 43880) oder
Ähnlichem
FRE Rigidité diélectrique
500V CA > 1 min par EN60730-1 entre
toutes les bornes et le coffret (DIN
43880) et d’autres
ITL Rigidità dielettrica
500V AC > 1 min. come da norma
EN60730-1 tra tutti i morsetti e l’unità di
controllo DIN 43880 o equivalente
ESP
Resistencia a tensiones
eléctricas
500V CA > 1 min por EN60730-1 entre
todos los terminales y la caja de control
DIN 43880 ó sus equivalentes
SWE Genomslagsspänning
500 V >1 min enligt EN60730-1 mellan
alla plintar och DIN 43880
styrenhetsbox eller motsvarande
RUS
Напряжение
диэлектрической прочности
Напряжение ~500В, более 1 минуты,
по стандартуr EN60730-1,
напряжение ме
жду всеми клеммами
и шкафом управления по стандарту
DIN43880 или между
эквивалентными точками
ENG Insulation Resistance
7 M, 500V DC EN60730-1 between all
terminals and the DIN43880 distribution
box or equivalent.
GER Isolationswiderstand
7 M, 500 V DC nach EN60730-1
zwischen allen Klemmen und dem
Schaltschrank nach DIN 43880
FRE Résistance d’isolement
7 M, 500 V CC selon EN60730-1 entre
toutes les bornes et l'armoire électrique
selon DIN 43880
ITL Resistenza di isolamento
7 M, 500 V CC conf. EN60730-1 fra
tutti i morseti ed il quadro elettrico ad
armadio conf. DIN 43880
ESP Resistencia de aislamiento
7 M, 500 V CC según EN60730-1
entre todos los bornes y el armario de
distribución según DIN 43880
SWE Isolationsresistans
7 M, 500 V DC enligt EN60730-1
mellan alla klämmor och elskåpet enligt
DIN 43880.
Item Specification
RUS Сопротивление изоляции
7 MОм, при напряжении постоянного
тока 500В по стандарту EN60730-1,
напряжение между всеми клеммами
и распределительной коробкой или
между эквивалентными точками.
ENG Operation Ambience To be free of corrosive gases
GER Umgebungsbedingungen Frei von aggressiven Gasen
FRE Conditions ambiantes Sans gaz agressif
ITL Condizioni ambientali Ambiente privo di gas aggressivi
ESP Condiciones de entorno Libre de gases agresivos
SWE Driftmiljö Fri från korrosiva gaser
RUS
Рабочая окружающая
среда
Не должна содержать агрессивных
газов
Item Specification
1RWH7KLVV\PEROPDUNLVIRU&KLQDRQO\
ਜ਼ᴹᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘
ǂ
ᵜӗ૱ѝᡰਜ਼ᴹⲴᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘૱ྲл㺘
ᡰ⽪DŽ
ӝ૷ѣᴿᇩ⢟䍞Ⲻ੃〦਀੡䠅
ᵜ㺘Ṭ׍ᦞ6-7Ⲵ㿴ᇊ㕆ࡦDŽ
สҾѝഭḷ߶⌅Ⲵ৲㘳㿴Ṭ*%7
ƻ
㺘⽪䈕ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴਜ਼䟿൷൘*%7
㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
h㺘⽪䈕ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴਜ਼䟿䎵ࠪ*%7
 㿴ᇊⲴ䲀䟿㾱≲DŽ
䜞Ԭ੃〦
ᴿᇩ⢟䍞
3E
+J
䭿
&G
ޣԭ䬢
&U9,
ཐ⓪㚊㤥
3%%
ཐ⓪ӂ㤥䟐
3%'(
ཆ༣
ঠࡧสᶯ
㔗⭥ಘ
⭥㔶
ƻƻ
ƻƻ ƻ ƻ ƻ
ƻƻ ƻ ƻ
h
ƻh ƻ ƻ ƻƻ
ƻƻ ƻ ƻ ƻh
ɇ⭫ಞ⭫ᆆӝ૷ᴿᇩ⢟䍞䲆࡬ֵ⭞ḽ䇼㾷≸ɈⲺ㺞⽰ᯯᕅ
Manual Number : JY997D09501
Manual Revision : H
Date : June 2018
JY997D09501H
Effective June 2018
Specifications are subject to
change without notice.
JY997D09501H
AL2-2TC-ADP
Installation Manual Installationsanleitung
Manuel d’installation Manuale di installazione
Manual de Instalación Installationshandbok
Руководство по установке
JY997D09501H
Caution
Persons trained in the local and national electrical standards must perform all
tasks associated with wiring the
α2 Series Controller and AL2-2TC-ADP.
Please use an isolated Power supply and turn off the Power before any wiring
operation is performed.
Input and Output cables should not be run through the same multicore cable or
share the same wire.
Input cable (from sensor to AL2-2TC-ADP) must be less than 10m (32’81’’)
and the output cable length must be less than 3m (9' 10").
The wire should be used as a single cable or the multicore wires (can be used
with a crimp terminal) should be carefully twisted together.
Do not connect a soldered wire end to the AL2-2TC-ADP.
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Do not install in areas with: excessive or conductive dust, corrosive or
flammable gas, moisture or rain, excessive heat, regular impact shocks or
excessive vibration.
The connectors must be covered to prevent contact with “Live” wires.
The
α2 Series Controller and AL2-2TC-ADP must be installed in a distribution
box or a control cabinet. The distribution box should be equipped with a cover
for the AL2-2TC-ADP module to avoid any possible foreign objects from falling
inside
Leave a minimum of 10mm (0.40") of space for ventilation between the top and
bottom edges of the AL2-2TC-ADP and the enclosure walls.
The
α2 Series is not designed to be used in life critical or fail safe applications.
Under no circumstances will Mitsubishi Electric be liable or responsible for any
consequential damage that may arise as a result of the installation or use of
this equipment.
Please read the
α2 Series Hardware and α2 Series Programming Manuals
for further information.
The AL2-2TC-ADP should be adjusted for offset and gain purposes, therefore,
turn off the Power before performing the adjustment wiring. Please refer to the
α2 Hardware manual for further details concerning offset and gain adjustment.
The maximum distance between the
α2 Series Controller and the AL2-2TC-
ADP should be 3m (9' 10") or less.
The power cable should be less than 10 m (32' 81") in length.
A sensor with insulation rated for 500 V or more should be used when the
sensor is placed near a conductive material.
Achtung
Nur speziell ausgebildetes Personal darf die elektrische Verdrahtung der
Geräte vornehmen. Sollten Sie spezialisierte Unterstützung brauchen, wenden
Sie sich an eine anerkannt ausgebildete Elektrofachkraft, die mit den lokalen
und nationalen Sicherheitsstandards der Automatisierungstechnik vertraut ist.
Verwenden Sie ein isoliertes Netzgerät, und schalten Sie vor allen
Verdrahtungsarbeiten die Spannung ab.
Die Ein- und Ausgangskabel dürfen nicht durch das gleiche Multikernkabel
oder den gleichen Kabelbaum verlegt werden.
Die Länge der Leitungen für Eingangssignale (vom Sensor zum AL2-2TC-
ADP) darf 10 m und die der Leitungen für Ausgangssignale darf 3 m nicht
überschreiten.
Verwenden Sie zum Anschluss Leitungen mit starren oder flexiblen Drähten
(für Crimp-Anschluss), die sorgfältig verdrillt sind.
Verwenden Sie keine flexible Drähte mit verlötetem Ende an einem AL2-2TC-
ADP.
Um eine Beschädigung der Kabel zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Die Geräte dürfen den folgenden Umgebungsbedingungen nicht ausgesetzt
werden: Umgebungen mit einem hohen Grad an leitfähigen Stäuben,
Korrosion, entzündbaren Gasen, Nebel, Regen, direkte Sonnenbestrahlung,
große Hitze, starke Schockwellen und Vibrationen.
Die Anschlüsse müssen abgedeckt werden, um Stromberührung zu
vermeiden.
•Die
α2-Steuerung und das AL2-2TC-ADP müssen in einen Schaltschrank
nach DIN 43880 oder einen Steuerkasten eingebaut werden. Das AL2-2TC-
ADP muss durch eine Abdeckung vor dem Eindringen von Fremdkörpern
geschützt werden.
Zur Kühlung muss zwischen der oberen und unteren Seite des AL2-2TC-ADP
und anderen Geräten ein Abstand von 10 mm eingehalten werden.
ENG
GER
•Die α2-Steuerung wurde nicht für lebenserhaltende oder selbstüberwachende
Anwendungen entwickelt.
MITSUBISHI ELECTRIC übernimmt unter keinen Umständen die Haftung oder
Verantwortung für einen Schaden, der aus einer unsachgemäßen Installation oder
Anwendung der Geräte oder des Zubehörs entstanden ist.
Weitere Informationen entnehmen Sie bitte der Hardware- und der
Programmieranleitung zur
α2-Steuerung.
Vor der Einstellung von Offset und Verstärkung am AL2-2TC-ADP muss die
Versorgungspannung ausgeschaltet werden. Nähere Hinweise zur Offset- und
Verstärkungseinstellung finden Sie in der Hardware-Beschreibung zur
α2-
Steuerung.
Die Leitung zwischen der
α2-Steuerung und dem AL2-2TC-ADP darf max. 3 m lang
sein.
Die Länge der Stromversorgungsleitungen darf 10 m nicht überschreiten.
Wird der Sensor in der Nähe von leitfähigen Material platziert, muss ein Sensor mit
einer Isolierung für min. 500 V verwendet werden.
Attention
Toutes les opérations liées au câblage du bloc logique α2 devraient être effectuées
par un technicien ou un ingénieur compétent en matière de normes électriques
nationales et locales.
Utilisez une alimentation isolée et déconnectez la tension avant tout travail de
câblage.
Les câbles d’entrée et de sortie ne devraient pas passer par un même câble
renfermant plusieurs conducteurs internes ou partager le même fil.
La longueur des lignes pour les signaux d'entrée (du capteur vers l'AL2-2TC-ADP)
ne doit pas dépasser 10 m et celle des lignes des signaux de sortie ne doit pas
dépasser 3 m.
Utilisez pour le raccordement des lignes avec des fils rigides ou flexibles (pour
raccordements sertis) qui sont torsadés soigneusement.
N'utilisez aucun fil flexible avec extrémité brasée sur l'AL2-2TC-ADP.
Afin d’éviter un endommagement du câble, serrer avec un couple de 0,5 - 0,6 Nm.
Ne pas installer le système dans des endroits dont l’atmosphère est riche en
poussières conductrices, en gaz corrosifs ou inflammables. Ne pas l'exposer à
l’humidité ou à la pluie, à une chaleur excessive, à des chocs ou à des vibrations
importantes.
Recouvrir les connecteurs pour éviter de vous blesser en touchant des fils “sous
tension”.
Le bloc logique
α2 doit être installé dans un coffret conforme à la norme DIN 43880
ou dans un boîtier de commande. L'AL2-2TC-ADP doit être protégé contre la
pénétration de corps étranger par un couvercle.
Pour le refroidissement, un espace de 10 mm doit être respecté entre les bords
supérieur et inférieur de l'AL2-2TC-ADP et les autres appareils.
La série
α2 n’est pas conçue pour être utilisée dans des applications
opérationnelles critiques ou à sécurité relative.
MITSUBISHI ELECTRIC décline toute responsabilité pour les dommages
imputables à une installation ou à une utilisation incorrecte des appareils ou des
accessoires.
Prière de lire les manuels du matériel des séries
α2et les manuels de
programmation des séries
α2 pour de plus amples informations.
Avant le réglage de l'offset et du gain sur l'AL2-2TC-ADP, la tension d'alimentation
doit être déconnectée. Vous trouverez de plus amples informations sur le réglage
de l'offset et du gain dans la description du matériel du bloc logique
α2.
La ligne entre le bloc logique
α2 et l'AL2-2TC-ADP doit avoir au maximum une
longueur de 3 m.
La longueur des lignes d'alimentation en courant ne doit pas dépasser 10 m.
Si le capteur est placé à proximité de matériel conducteur, un capteur avec une
isolation pour minimum 500 V doit être utilisé.
Attenzione
Tutte le operazioni relative al cablaggio elettrico dei microcontrollori della serie α2
devono essere effettuate da un tecnico esperto in materia di standard elettrici locali
e nazionali.
Utilizzare un alimentatore di rete isolato e prima di tutti i lavori di cablaggio
disconnettere la tensione di alimentazione.
I cavi di ingresso e di uscita non devono essere instradati nello stesso cavo
multipolare o condividere lo stesso filo.
La lunghezza dei circuiti dei segnali di ingresso (dal sensore fino a AL2-2TC-ADP)
non deve superare i 10 m e quella dei circuiti dei segnalidi uscita non deve superare
i 3 m.
Il cablaggio dovrebbe essere eseguito usando filo singolo e crimpando lo stesso ad
un capicorda o avvolgendo accuratamente la trecciola.
Non usare cavi flessibili con estremità saldata su AL2-2TC-ADP.
Per evitare danneggiamenti del filo, serrare con una coppia di 0,5 - 0,6 Nm.
Non installate in aree soggette a: polvere eccessiva o conduttiva, gas corrosivo o
infiammabile, umidità o pioggia, calore eccessivo, urti regolari o vibrazione
eccessiva.
I connettori devono essere coperti per evitare il rischio di lesioni dovute al contatto
con conduttori “sotto tensione”.
FRE
ITL
I microcontrollori
α
2 devono essere installati in cassette progettate per
l'installazione di dispositivi conformi alla norma DIN 43880. Il modulo AL2-2TC-ADP
deve essere protetto con un involucro per evitare che vi penetrino corpi estranei.
Per il raffreddamento fra la parte in alto ed in basso del modulo AL2-2TC-ADP ed
altri apparecchi, si deve mantenere una distanza di 10 mm.
Il microcontrollore
α
2 non è progettato per essere utilizzao in applicazioni critiche
quali quelle di sicurezza e quelle a rischio di vita.
La MITSUBISHI ELECTRIC non si assume alcuna responsabilità per danni causati
da un’installazione o un funzionamento inadeguato degli apparecchi o degli
accessori.
Per favore leggere il manuale hardware dell'
α
2 e il manuale di programmazione
per ulteriori informazioni.
Prima di regolare offset ed guadagno, la tensione di alimentazione su AL2-2TC-
ADP deve essere scollegata. Istruzioni più dettagliate sulla regolazione di offset e
guadagno si trovano nella descrizione dell´hardware relativa al microcontrollore
α
2.
La lunghezza del cavo di collegamento tra il microcontrollore
α
2 e il modulo AL2-
2TC-ADP non deve superare i 3 m.
La lunghezza delle line di alimentazione di corrente non deve superare 10 m.
Se un sensore viene sistemato vicino a materiale conduttivo, si deve usare un
sensore con una tensione di isolamento di almeno 500 V.
Atención
Un técnico o ingeniero experimentados en los estándares eléctricos nacionales y
locales debe realizar todas las tareas asociadas con el cableado eléctrico del
α
2
.
Utilice un bloque de alimentación aislado y desconecte la tensión antes de realizar
los trabajos de cableado.
Los cables de entrada y salida no deben ser pasados a través del mismo cable
multieje o compartir el mismo alambre.
La longitud de las líneas para las señales de entrada (desde el sensor al AL2-2TC-
ADP) no debe exceder los 10 m, así como los 3 m en caso de las líneas para las
señales de salida.
Para la conexión deben utilizarse líneas con alambres rígidos o flexibles (para
conexión de engarzado a presión) que están cuidadosamente torcidos.
En el AL2-2TC-ADP no han de utilizarse alambres flexibles con extremos soldados.
Para evitar daños del cable, debe aplicarse un torque de 0,5 - 0,6 Nm.
El diseño seguro de
α2 Series significa que el usuario puede instalarlo casi en
todas partes, pero se deberían tomar en consideración los siguientes puntos. No lo
instale en zonas con polvo excesivo o conductor, corrosivos o gas inflamable,
humedad o lluvia, calor excesivo, impactos usuales o vibración excesiva.
Los conectores deben estar recubiertos para prevenir algún daño por contacto con
los alambres “energizados”.
•El
α2 debe instalarse en gabinetes que estén diseñados para el conjunto de
dispositivos, que cumplen con DIN 43880 o en una caja de control. ·El control
α2 y
el AL2-2TC-ADP debe instalarse en un armario de distribución cerrado según la
norma DIN 43880 o bien en una caja de mando. El AL2-2TC-ADP debe protegerse
mediante una cubierta frente al ingreso de cuerpos extraños.
Para la refrigeración debe mantenerse una distancia de 10 mm entre el lado
superior e inferior del AL2-2TC-ADP y de los demás aparatos.
•El
α2 no está diseñado para utilizar en situaciones críticas que ponen la vida en
peligro ni en aplicaciones de seguridad contra averías.
MITSUBISHI ELECTRIC no asumirá responsabilidad alguna de los daños que se
hayan podido producir por causa de una instalación inadecuada o por un uso
inapropiado tanto de las unidades como de los accesorios.
Para mayores informaciones, le rogamos leer los Manuales de Programación y
Hardware de la serie
α2.
Antes de la regulación de la desviación y de la ganancia en el AL2-2TC-ADP debe
desconectarse la tensión de alimentación. Mayor información acerca de la
regulación de la desviación y de la ganancia se encuentra en la descripción de
hardware para el control
α2.
La línea entre el control
α2 y el AL2-2TC-ADP debe tener una longitud máxima de
3 m.
La longitud de las líneas de alimentación de corriente no deben sobrepasar los 10
m.
Al colocar un sensor en la cercanía de material conductor, debe utilizarse un sensor
con una aislación para al menos 500 V.
Viktigt
Alla arbetsuppgifter rörande elektrisk anslutning av styrenheter i α2-serien måste
utföras av tekniker med utbildning i och erfarenhet av lokala och nationella regler för
elarbeten.
Det använda nätaggregatet ska vara isolerat och spänningen vara frånslagen innan
arbeten med kabeldragningen påbörjas.
In- och utgående kablar skall inte dras i samma flerledarkabel eller dela samma
ledare.
Ledningarna för ingångssignalerna (från sensorn till AL2-2TC-ADP) får inte vara
längre än 10 m och ledningarna för utgångssignalerna inte längre än 3 m.
För anslutningen ska ledningar med styva eller flexibla ledare användas (för
crimpanslutning) vilka är omsorgsfullt tvinnade.
Använd inga flexibla ledare med fastlödda ändar på AL2-2TC-ADP.
ESP
SWE
För att undvika att skada kabeln, drar du åt med 0,5 - 0,6 Nm.
Installera inte i områden med mycket damm, ledande damm, korrosiv eller
brännbar gas, fukt eller regn, stark värme, kraftiga stötar eller kraftig vibration.
Anslutningarna måste vara täckta, för att förhindra kontakt med
spänningsförande ledare.
Styrenheten serie
α2 måste installeras i skåp avsedda för montering av
enheter som uppfyller DIN 43880, eller i en styrenhetsbox. AL2-2TC-ADP
måste täckas över för att skydda den mot främmande partiklar.
För att säkerställa kylningen måste avståndet från över- och undersida på AL2-
2TC-ADP till andra apparater uppgå till 10 mm.
α2 är inte avsedd att användas i livskritiska eller felsäkra tillämpningar.
Mitsubishi Electric är under inga omständigheter ersättningsskyldigt eller
ansvarigt för följdskador som kan uppstå till följd av installation eller
användning av utrustningen.
Ytterligare information finns i maskinvaruhandboken för
α2- och
programmeringshandboken för
α2-serien.
Innan offset och förstärkning på AL2-2TC-ADP ställs in måste
försörjningsspänningen slås från. För närmare information om inställning av
offset och förstärkning se beskrivningen av hårdvara för
α2-styrningen.
Ledningen mellan
α2-styrningen och AL2-2TC-ADP får inte vara längre än
max. 3 m.
Elledningen får inte vara längre än 10 m.
Placeras sensorn i närheten av ledande material, skall en sensor med en
isolering på minst 500 V användas.
Внимание
К работам по монтажу контроллера серии
α
2 и модуля AL2-2TC-ADP
допускаются только квалифицированные электрики, прошедшие
подготовку к электромонтажным работам в соответствии с местными и
государственными стандартами.
Используйте изолированный источник питания и отключите
электропитание, прежде чем приступать к каким-либо электромонтажным
работам.
Кабели входных и выходных цепей не должны проходить в одном и том
же многожильном кабеле; в кабелях вх
одных и выходных цепей не
должны использоваться общие провода.
Длина входного кабеля (от датчика к модулю AL2-2TC-ADP) не должна
превышать 10 м, длина выходного кабеля не должна превышать 3 м.
Для подключения следует использовать одинарный провод, обжимку или
аккуратно скрутить многожильный провод.
Не подключайте к модулю AL2-2TC-ADP паяный конец провода
Чтобы не повредить п
ровод, затягивайте его с вращательным моментом
0,5-0,6 Нм.
Не допускается установка устройства в местах с повышенным
содержанием пыли, а также в местах, где пыль является
электропроводящей или в воздухе присутствуют агрессивные или
воспламеняющиеся газы; под дождем или в местах с повышенной
влажностью, либо там, где устройство может быть подвержено
избыточному нагреванию, виб
рации или регулярным ударным
воздействиям.
Соединительные разъемы должны быть закрыты, чтобы избежать
соприкосновения с проводами, находящимся под напряжением.
Контроллер серии
α
2 следует установить в распределительную коробку
или шкаф управления. Распределительная коробка должна быть
снабжена крышкой для модуля AL2-2TC-ADP, чтобы исключить
попадание внутрь посторонних предметов.
Оставьте между верхом и низом модуля AL2-2TC-ADP и окружающими
стенками коробки зазор для вентиляции минимум 10 мм.
Контроллер серии
α
2 не рассчитан на применение в условиях,
требующих полной отказоустойчивости, либо критичных для жизни
человека.
Mitsubishi Electric ни при каких обстоятельствах не несет ответственности
за какие-либо повреждения, которые могут оказаться следствием
установки или эксплуатации данного устройства.
Дальнейшую информацию вы найдете в Руководстве по аппаратной
части контроллера серии
α
2 или в Руководстве по программированию
контроллера серии
α
2.
В модуле AL2-2TC-ADP необходимо выставить величины смещения и
усиления; перед выполнением этой регулировки выключите
электропитание. Для получения дальнейшей информации по регулировке
величин смещения и усиления см. Руководстве по программированию
контроллера серии
α
2.
Максимальное расстояние между контроллером серии
α
2 и модулем
AL2-2TC-ADP не должно превышать 3 м.
Длина кабеля от источника питания не должна превышать 10 м.
Если датчик расположен вблизи проводящего материала, его изоляция
должна быть рассчитана на номинальное напряжение не менее 500 В.
RUS
1. DIMENSIONS
Figure1. Dimensions
Abmessungen
Dimensions
Dimensioni
Dimensiones
Mått
Габариты
Table 1. Allocation of Terminals
Klemmenbelegung
Affectation des bornes
Significato dei morsetti
Ocupaciones de bornes
Plintlayout
Расположение контактных клемм
Ref. Item Description
1
24+
24-
ENG +24V DC Power Supply
GER +24 V DC Eingangsklemme
FRE +24 V CC borne d'entrée
ITL Morsetto di Alimentazione +24 V CC
ESP +24 V CC Terminal de entrada
SWE +24 V DC ingångsklämma
RUS Источник питания +24 В постоянного тока
2
V1+
V1-
ENG Channel 1 Voltage Output Terminal
GER Kanal 1: Spannungsausgang
FRE Canal 1 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 1
ESP Canal 1 Terminal de salida de tensión
SWE Kanal 1 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 1
3
V2+
V2-
ENG Channel 2 Voltage Output Terminal
GER Kanal 2: Spannungsausgang
FRE Canal 2 borne de sortie de tension
ITL Morsetto di uscita tensione, Canale 2
ESP Canal 2 Terminal de salida de tensión
SWE Kanal 2 spännings-utgångsklämma
RUS Контактная клемма выходного напряжения канала 2
ENG
GER
FRE
ITL
ESP
SWE
RUS
60(2.37")
90(3.55")
31.0(1.23")
1.5(0.06")
35.5(1.40")
15(0.60")
15(0.60")
8
7
4
5
1 2 3
6
5
Unit: mm(inches)
ENG
GER
FRE
ITL
ESP
SWE
RUS
2. INSTALLATION DIAGRAMS
Figure2. Installation Diagrams
Installations-Skizze
Diagrammes d'installation
Schema di installazione
Esquemas de instalación
Installation
Схемы установки
4
L1+
L1-
ENG Channel 1 K-type Thermocouple Sensor Input Terminal
GER Kanal 1: Anschluss für Thermoelement Typ K
FRE Canal 1: Branchement pour thermocouple de type K
ITL Canale 1: connessione per termoelemento tipo K
ESP Canal 1: Conexión para termoelemento del tipo K
SWE Kanal 1: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 1
5SLD
ENG Shield Grounding Terminal
GER Masseanschluss für die Abschirmung
FRE Borne de masse pour le blindage
ITL Connessione per la schermatura
ESP Conexión a masa para el blindaje
SWE Anslutning av skärm
RUS Контактная клемма заземления экрана
6
L2+
L2-
ENG Channel 2 K-type Thermocouple Sensor Input Terminal
GER Kanal 2: Anschluss für Thermoelement Typ K
FRE Canal 2: Branchement pour thermocouple de type K
ITL Canale 2: connessione per termoelemento tipo K
ESP Canal 2: Conexión para termoelemento del tipo K
SWE Kanal 2: Anslutning för termoelement typ K
RUS Контактная клемма термопары К-типа канала 2
7
ENG Jumper pins for adjustment
GER Jumper zur Einstellung des Moduls
FRE Cavalier pour le réglage du module
ITL Ponticello per l'impostazione del modulo
ESP Puente para la regulación del módulo
SWE Jumper för inställning av modul
RUS Штырьки перемычек для настройки
8
ENG Power LED
GER Power-LED zur Anzeige der Betriebsbereitschaft
FRE DEL alimentation pour l'affichage de l'état de service
ITL
Led "POWER" per l'indicazione dello stato di
funzionamento del modulo.
ESP LED de potencia, indica la disposición de servicio
SWE Power-LED, indikerar spänningsmatning
RUS Светодиодный индикатор подачи питания
Ref. Item Description
ENG
GER
FRE
ITL
ESP
SWE
RUS
Attach
(1)
(2)
(
1
)
(2)
Release
When installing the AL2-2TC-ADP module refer to Figure 2.
Units can be snap mounted to 35mm DIN rail (DIN EN 50022). To release pull the spring
loaded clips away from the rail and slide the unit off and up.
a) To Attach
Align the upper side of the AL2-2TC-ADP DIN rail mounting groove with the DIN rail
(1) and push it onto the rail (2).
b) To Release
Pull the DIN rail hook (1) and remove the AL2-2TC-ADP (2).
Installieren Sie das AL2-2TC-ADP so, wie in Figure 2 gezeigt.
Das Modul kann auf eine DIN-Schiene (35 mm, DIN EN 50022) montiert werden. Zur
Demontage ziehen Sie an den mit einer Feder versehenen Riegel und nehmen das Modul
von der Schiene.
a) Montage
Setzen Sie das AL2-2TC-ADP mit der oberen Seite auf die DIN-Schiene (1) und
drücken Sie das Modul auf die Schiene (2).
b) Demontage
Ziehen Sie den Riegel nach unten (1) und entfernen Sie das AL2-2TC-ADP (2).
Installez l'AL2-2TC-ADP comme indiqué dans la figure 2.
Le module peut être monté sur un rail DIN (35 mm, DIN EN 50022). Pour le démontage,
tirez sur le verrouillage équipé d'un ressort et enlevez le module du rail.
a) Montage
Placez l'AL2-2TC-ADP avec la face supérieure sur le rail DIN (1) et POUSSEZ le
module sur le rail (2).
b) Démontage
Tirez le verrouillage vers le bas (1) et enlevez l'AL2-2TC-ADP (2).
Installare AL2-2TC-ADP come illustrato nella figura 2.
Il modulo può essere montato su una guida (35 mm, DIN EN 50022). Per lo smontaggio
spingere verso il basso il modulo provvisto di una molla e togliere il modulo dalla guida.
a) Montaggio
Mettere il modulo AL2-2TC-ADP con il lato superiore sulla guida Din (1) e premere
il modulo sulla guida (2).
b) Smontaggio
Spingere il blocco verso il basso (1) e toglierlo (2).
Instale el AL2-2TC-ADP según las indicaciones en la figura 2.
El módulo puede montarse sobre un riel DIN (35 mm, DIN NE 50022). Para el desmontaje
debe extraerse el pasador equipado con un resorte y retirarse el módulo del riel.
a) Montaje
Coloque el AL2-2TC-ADP con la parte superior sobre el riel DIN (1) y empuje el
módulo sobre el riel (2).
b) Desmontaje
Extraiga el pasador hacia abajo (1) y retire el AL2-2TC-ADP (2).
För installationen av AL2-2TC-ADP se bild 2.
Modulen kan monteras på en DIN-skena (35 mm, DIN EN 50022). För demontering drag i
den fjäderförsedda regeln och lyft bort modulen från skenan.
a) Montage
Placera AL2-2TC-ADP med den övre sidan på DIN-skenan (1) och tryck fast mod-
ulen på skenan (2).
b) Demontage
Drag regeln nedåt (1) och lyft bort AL2-2TC-ADP (2).
Перед установкой модуля AL2-2TC-ADP ознакомьтесь с рис. 2.
Устройства можно монтировать на защелке к 35 мм рельсу DIN (DIN EN 50022).
Чтобы снять устройство с рельса, оттяните подпружиненные зажимы от рельса и
сдвиньте устройство вверх.
a) Для установки: совместите верхний край канавки на корпусе модуля AL2-2TC-
ADP с рельсом DIN (1) и защелкните его на рельсе (2).
b) Для съема
Оттяните крючок (1) и снимите модуль AL2-2TC-ADP (2) с рельса DIN.
3. WIRING DIAGRAMS
Figure3. End Processing of Cable
Bearbeitung der Leiterenden
Manipulation de fin de câble
Preparazione del cavo
Fin de procesamiento del cable
Kabelns ände
Оконцевание кабеля
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Wire the Inputs and Outputs using 26 - 12 AWG wire (0.13 mm
2
-
3.31 mm
2
).
To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 Nm.
Multicore cable: Remove sheath, twist core wires, then connect
cable (or use a crimp terminal).
Single cable: Remove sheath, then connect cable.
Verwenden Sie für die Eingänge und Ausgänge Leitungen mit einem
Aderquerschnitt von 0,13 mm
2
- 3,31 mm
2
(26 - 12 AWG).
Um eine Beschädigung der Leitungen zu vermeiden, drehen Sie die
Klemmenschrauben mit einem Drehmoment von 0,5 bis 0,6 Nm an.
Flexible Leitung: Isolation entfernen, Aderendhülsen anbringen
oder Litze verdrillen und Leitung anschließen.
Starre Leitung: Isolation entfernen und Leitung anschließen.
Raccordez les entrées et les sorties avec des fils de 0,13 mm
2
à
3,31 mm
2
(26 - 12 AWG).
Afin d'éviter un endommagement du câble, serrer avec un couple de
0,5-0,6 Nm.
Ligne flexible: Enlever la gaine, le fil central de torsion et
connecter ensuite le câble (ou utiliser une borne
sertie).
Câble simple: Enlever la gaine et connecter ensuite le câble.
Collegare gli ingressi e le uscite con fili di diam. da 0,13 mm
2
- 3,31
mm
2
.
Per evitare di danneggiare il filo, serrare con una coppia di 0,5-0,6
Nm.
Cavo a trecciola: Togliere la guaina, torcere l´anima dei fili, poi
collegare il cavo (o usare un capocorda a
crimpare).
Cavo rigido: Togliere la guaina, poi collegare il cavo.
Alambrar las entradas y salidas usando alambre de 0,13 mm
2
- 3,31
mm
2
(26 - 12 AWG).
Para evitar daños del cable, debe aplicarse un torque de 0,5-0,6
Nm.
Línea flexible: Remover el revestimiento, retorcer las almas y
conectar luego el cable (o utilizar un terminal de
presión).
Cable único: Remover el revestimiento y conectar luego el
cable.
Anslut in-och utgångarna med kabel 26 -12 AWG (0,13 - 3,31 mm
2
).
För att undvika att skada kabeln, drar du åt med 0,5-0,6 Nm.
Flexibel ledning: Avlägsna höljet, tvinna trådarna och anslut
kabeln (eller använd klämkoppling).
Entrådig kabel: Avlägsna höljet och anslut kabeln.
Подключение входных и выходных цепей производится с
помощью проводов сечением 26 – 12 по стандарту AWG (0,13
мм
2
– 3,31 мм
2
).
Чтобы не повредить провод, затягивайте его с вращательным
моментом 0,5-0,6 Нм
Многожильный кабель: удалите изоляцию, скрутите провода,
затем подсоедините кабель (или
используйте обжимку)
Одинарный провод: удалите изоляцию, затем
подсоедините провод
4. WIRING
Note:
When wiring DC supplies the "positive" cable should be con-
nected to the "+" terminal and the negative cable should be con-
nected to the "-" terminal. On no account should the power supply
terminals be connected to any other terminal on the unit. Revers-
ing the terminals will seriously damage the AL2-2TC-ADP expan-
sion module.
Under no circumstances should AC voltage be used as the AL2-
2TC-ADP expansion module will be seriously damaged.
Do not lay signal cabling near to high voltage power cables or
house them in the same trunking duct. Effects of noise or surge
induction may occur. Keep signal cables a safe of more than 100
mm (3.94") distance away from these power cables.
The AL2-2TC-ADP and
α2 Series main unit must use the same
power supply.
7mm(0.276") ±0.5mm(0.02")
26 -12 AWG
Temperature Rating: Min. 80ºC (176ºF)
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Hinweis:
Beim Anschluss der DC-Versorgungsspannung muss das „posi-
tive“ Kabel mit der Klemme „+“ und das „negative“ Kabel mit der
Klemme „-“ verbunden werden. Auf keinen Fall darf die Span-
nungsversorgung an eine andere Klemme des Moduls ange-
schlossen werden. Ein Vertauschen der Klemmen kann zu einer
schweren Beschädigung des AL2-2TC-ADP führen.
Der Anschluss einer AC-Spannungsquelle an das Erweiterungs-
modul AL2-2TC-ADP kann zu einer schweren Beschädigung des
Moduls führen.
Velegen Sie zur Vermeidung von Störungen die Signalleitungen
nicht in die Nähe von Leitungen, die hohe Ströme oder Spannun-
gen übertragen.
Signalleitungen dürfen auch nicht zusammen mit diesen Leitun-
gen im selben Kabelkanal verlegt werden. Der Mindestabstand
beträgt 100 mm.
Das AL2-2TC-ADP und die
α2-Steuerung müssen von derselben
Spannungsquelle versorgt werden.
Note:
Lors du raccordement de la tension d'alimentation CC, le câble
"positif" doit être relié avec la borne "+" et le câble "négatif" avec
la borne "-". En aucun cas, la tension d'alimentation doit être rac-
cordée à une autre borne du module. Une permutation des
bornes peut entraîner un grave endommagement de l'AL2-2TC-
ADP.
Le raccordement d'une source de tension CA sur le module
d'extension AL2-2TC-ADP peut entraîner un grave endommage-
ment du module.
Ne posez pas les lignes de signaux à proximité de lignes qui
transmettent des courants ou tensions élevés afin d'éviter des
perturbations. Les lignes de signaux ne doivent pas non plus être
posées dans un caniveau électrique commun. L'écart minimal est
de 100 mm.
L'AL2-2TC-ADP et le bloc logique
α2 doivent être alimentés par
la même source de tension.
Avvertenza:
Per la connessione della tensione CC di alimentazione il cavo
"positivo" deve essere collegato al morsetto "+" e quello "nega-
tivo" al morsetto "-". In nessun caso l´alimentazione di tensione
deve essere connessa ad un altro morsetto del modulo. Se si
confondono i morsetti si possono avere gravi danneggiamenti
dello AL2-2TC-ADP.
La connessione di una sorgente di tensione AC al modulo di
ampliamento AL2-2TC-ADP può provocare gravi danneggiamenti
al modulo.
Per evitare disturbi non posare i circuiti dei segnali vicino a linee o
circuiti che trasmettono correnti o tensioni alte. I circuiti dei
segnali non devono essere posati con tali linee/circuiti nello
stessa canala portacavi. La distanza minima fra queste linee deve
essere di minimo 100 mm.
Il modulo AL2-2TC-ADP ed il microcontrollore
α2 devono essere
alimentati dalla stessa sorgente di tensione.
Observación:
En la conexión de la tensión de alimentación CC debe conectarse
el cable "positivo" con el borne "+" y el cable "negativo" con el
borne "-". En ningún caso debe conectarse la alimentación de
tensión con otro borne del módulo. Un cambio de los bornes
puede causar graves daños en el AL2-2TC-ADP.
La conexión de una fuente de tensión AC en el módulo de ampli-
ación AL2-2TC-ADP puede causar graves daños en el módulo.
Para evitar perturbaciones de las líneas de señal, éstas no deben
tenderse en la cercanía de líneas que transfieren flujos o ten-
siones de alta intensidad. Las líneas de señal no deben tenderse
tampoco en conjunto con estas líneas en un mismo canal para
cables.
La distancia mínima es de 100 mm
.
El AL2-2TC-ADP y el control
α2 deben alimentarse con la misma
fuente de tensión.
Observera:
Vid anslutning av DC-försörjningsspänning måste den "positiva"
kabeln anslutas till klämma"+" och den "negativa" kabel till
klämma "-". Spänningsförsörjningen får på inga villkor anslutas till
en av modulens andra klämmor. En förväxling av klämmorna kan
leda till avsevärda skador på AL2-2TC-ADP.
En anslutning av en AC-spänningskälla till tillsatsmodul AL2-2TC-
ADP kan leda till avsevärda skador på modulen.
För att undvika störningar får signalledningarna inte läggas i
närheten av ledningar som överför stark ström eller spänningar.
Signalledningar får inte heller läggas i samma kabelkanal som
dessa ledningar. Minimiavståndet ska uppgå till 100 mm.
Spänningen för AL2-2TC-ADP och
α2-styrningen måste komma
från samma källa.
GER
FRE
ITL
ESP
SWE
Примечание:
При подключении к источнику питания постоянного тока «+»
источника питания следует присоединять к клемме «+», а «-»,
соответственно, к клемме «-».
Ни при каких условиях не следует присоединять источник питания
к каким-либо другим клеммам устройства. Обратное подключение
(«+» на «-») вызовет серьезные повреждения модуля расширения
AL2-2TC-ADP.
Ни при каких условиях не следует подключать модуль расширения
A
L2-2TC-ADP к источнику переменного тока, поскольку это
приведет к серьезным повреждениям данного устройства.
Не прокладывайте сигнальные кабели рядом с высоковольтными
силовыми кабелями, и не помещайте их в один кабельный канал
это может привести к появлению помех и импульсных наводок.
Безопасным расстоянием между этими кабелями является 100мм
и более.
Питание модуля A
L2-2TC-ADP и контроллера серии α2 должно
подаваться от одного источника.
Figure4.
EMC Caution:
Users may temporarily experience errors not exceeding +/- 10% of the
actual value when the AL2-2TC-ADP is used in excessive EMC fields.
Please refer to
α2 Hardware Manual for further details.
EMC-Vorsichtsmaßnahmen:
Wird das AL2-2TC-ADP in Bereichen mit starken elektromagnetischen
Störeinstrahlungen eingesetzt, können zeitweise Fehler auftreten, die +/-10
% des aktuellen Wertes überschreiten. Nähere Hinweise finden Sie in der
Hardware-Anleitung zur
α2-Steuerung.
Mesures CEM de précautions:
Si l'AL2-2TC-ADP est implanté dans des endroits avec de forts
rayonnements électromagnétiques perturbateurs, des erreurs pouvant
atteindre au maximum +/-10 % de la valeur actuelle peuvent
temporairement apparaître.
Misure precauzionali per le EMC:
Se si impiega il modulo AL2-2TC-ADP in zone con forti interferenze
elettromagnetiche di quando in quando possono verificarsi errori, che non
superano +/-10% del valore attuale. Maggiori dettagli si trovano nelle
istruzioni per l´hardware relative al microcontrollore
α2.
Medidas de precaución CEM:
Cuando se aplica el AL2-2TC-ADP en áreas con una fuerte radiación
perturbadora electromagnética, pueden presentarse temporalmente fallas
que no superan el +/-10% del valor actual. Mayores indicaciones se
encuentran en las instrucciones de hardware para el control
α2.
EMC-säkerhetsanvisningar:
När AL2-2TC-ADP används i områden med starka elektromagnetiska
störningsfält kan temporära fel uppstå, dessa får inte överstiga +/-10 % av
det aktuella värdet. För närmare information vänligen se
α2-styrenhetens
hårdvaramanual.
RUS
24V
DC
24+ 24- V1+ V1- V2+ V2-
+15V
3k 3k
L1+ L1- SLD L2+ L2- SLD
Grounding
resistance
100
or
less
K-type
Thermocouple
K-type
Thermocouple
+-(A)(B)12
AL2-14MR-D/
AL2-24MR-D
AL2-2TC-
ADP
Temprature
compensation
circuit
Grounding
resistance
100
or
less
Shielded
Shielded
0.5A
1.0A
ENG
GER
FRE
ITL
ESP
SWE
Предупреждение по электромагнитной
совместимости:
При работе модуля AL2-2TC-ADP в сильных электромагнитных полях
возможно появление ошибок, не превышающих +/- 10% фактического
значения величин. Для получения дальнейшей информации см.
Руководство по аппаратной части контроллера
α2.
5. PERFORMANCE SPECIFICATIONS
The AL2-2TC-ADP thermocouple analog sensor adaptor module (hereafter
called “AL2-2TC-ADP”) should be used to amplify thermocouple sensor
(K type) temperature input to 0 - 10V voltage analog signal for use in the
main unit. The main unit can only be a DC type
α
2 Series Controller
ver 2.0 or later. Refer to the
α2 Programming and Hardware manuals for
further details concerning the AL2-2TC-ADP.
Das Thermoelement-Adapter-Modul AL2-2TC-ADP wandelt die mit einem
Thermoelement erfasste Temperatur in eine Spannung von 0 bis 10 V um.
Es kann nur ein
α
2 -Hauptmodul mit Gleichspannungsversorgung ab
der Version 2.0 verwendet werden. Nähere Hinweise zur
Programmierung und zur Hardware finden Sie in den Handbüchern zur
α2-Steuerung.
Le module adaptateur de thermocouple AL2-2TC-ADP convertit la
température saisie avec un thermocouple en une tension de 0 à 10 V. Seul
un module principal
α
2 avec alimentation en tension continue de
version 2.0 ou supérieure peut être utilisé. Vous trouverez des plus
amples informations sur la programmation et sur le matériel dans les
manuels du bloc logique
α2.
Il modulo adattatore per il termoelemento AL2-2TC-ADP trasforma la
temperatura rilevata con un termoelemento in una tensione fra 0 e 10 V. Si
può usare solo un modulo principale
α
2 con alimentazione in CC a
partire dalla versione 2.0. Informazioni più dettagliate per la
programmazione e per l´hardware si trovano nei manuali relativi al
microcontrollore
α2.
El módulo adaptador para el termoelemento AL2-2TC-ADP transforma la
temperatura obtenida hacia una tensión de 0 a 10 V. Se puede utilizar
solamente un módulo principal
α
2 con alimentación de corriente
continua a partir de la versión 2.0. Mayor información acerca de la
programación y el hardware se encuentra en los manuales para el control
α2.
Termo-adapter-modul AL2-2PT-ADP omvandlar signalen från ett
termoelement till en spänning på 0 till 10 V
. Huvudmodulen skall vara av
α
2-typ med likströmsförsörjning från version 2.0 eller senare.
För närmare information om programmering och hårdvara se handböckerna
för
α
2-styrenheten.
Модуль адаптера AL2-2TC-ADP для термопар (далее называемый
«модуль AL2-2TC-ADP») предназначен для преобразования сигнала
термопар (К-типа) и получения аналогового сигнала в диапазоне 0–
10В, который используется в главном блоке. Главным блоком при
этом может являться только контроллер серии
α2 версии 2.0 или
более поздней, подключаемый к источнику постоянного тока. Для
получения дальнейшей информации по модулю AL2-2TC-ADP см.
Руководство по программному обеспечению контроллера
α2.
Table 2. Adjustment Standard
EC Directive EMC
EN61131-2:2007
EN60730-1:2011
Certification of UL/cUL File number: E95239
RUS
ENG
GER
FRE
ITL
ESP
SWE
RUS
Table 3. Analog Input Characteristics
Item Centigrade (°C) Fahrenheit (°F)
ENG Input Specification
Thermocouple K type, JIS 1602-1995 (IEC
584-1 1977, IEC 584-2 1982), Isolated type
GER Thermoelement-
Eingang
Isoliertes Thermoelement Typ K (IEC 584-1
1977, IEC 584-2 1982)
FRE Entrée du
thermocouple
Thermocouple isolé de type K (IEC 584-1
1977, IEC 584-2 1982)
ITL Ingresso del
termoelemento
Termoelemento isolato tipo K (IEC 584-1 1977;
IEC 584-2 1982)
ESP Entrada del
termoelemento
Termoelemento aislado del tipo K (IEC 584-1
1977, IEC 584-2 1982)
SWE Termoelement-ingång
Isolierat termoelement typ K (IEC 584-1 1977,
IEC 584-2 1982)
RUS Входные
характеристики
Термопара К-типа, JIS 1602-1995 (IEC 584-1
1977, IEC 584-2 1982), изолированный тип
ENG Compensated Range
-50°C - 450°C-58°F - 842°F
GER Kompensierter Bereich
FRE Plage compensée
ITL Intervallo di lettura
ESP Rango compensado
SWE Kompenserat område
RUS Компенсируемый
диапазон
ENG Overall accuracy
±2.0% (range of all
temperatures) and
±1.5% (at 25°C)
±2.0% (range of all
temperatures) and
±1.5% (at 77°F)
GER Genauigkeit
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 25 °C
±2,0 % (bei allen
Temperaturen) und
± 1,5 % bei 77 °F
FRE Précision
±2,0 % (pour toutes
les températures) et
± 1,5 % à 25 °C
±2,0 % (pour toutes
les températures) et
± 1,5 % à 77°F
ITL Precisione
±2,0% (per tutte le
temperature) e
± 1,5% a 25 °C
±2,0% (per tutte le
temperature) e
± 1,5% a 77°F
ESP Precisión
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 25 °C
±2,0 % (con todas las
temperaturas) y ± 1,5
% con 77°F
SWE Noggrannhet
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 25 °C
±2,0 % (vid alla
temperaturer) och
± 1,5 % vid 77°F
RUS Об
щая погрешность
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 25°C)
±2,0% (во всем
температурном
диапазоне) и ±1,5%
(при 77°F)
ENG Resolution
1°C
GER Auflösung
FRE Résolution
ITL Risoluzione
ESP Resolución
SWE Upplösning
RUS Разрешение
ENG Conversion Speed
20.5ms
GER Wandlungszeit
FRE Temps de conversion
ITL Tempo di
commutazione
ESP Duración de conversión
SWE Omvandlingstid
RUS Скорость
преобразования
ENG Isolation
No isolation between channels (input/output)
and power
GER Isolation
Keine Isolation zwischen den Kanälen (Ein-
oder Ausgang) und der Stromversorgung.
Note:
Please refer to the α 2 Programming and Hardware Manual for
further details concerning Gain and Offset adjustment for the AL2-
2TC-ADP module.
Hinweise zur Offset- und Verstärkungseinstellung beim AL2-2TC-
ADP finden Sie in den Programmier- und Hardware-Handbüchern zur
α2-Steuerung.
Vous trouverez des indications sur le réglage de l'offset et du gain pour
l'AL2-
2TC
-ADP dans les manuels de programmation et du matériel du
bloc logique
α
2.
Istruzioni per la regolazione di offset e guadagno per AL2-
2TC
-
ADP si trovano nei manuali di programmazione e dell´hardware relativi
al microcontrollore
α
2.
Mayor información acerca de la regulación de la desviación y de la
ganancia del AL2-2TC-ADP se encuentra en los manuales de
programación y hardware para el control
α2.
För närmare information om inställning av offset och förstärkning i
AL2-2TC-ADP se programmerings- och hårdvarahandböcker för
α2-
styrningen.
Для получения дальнейшей информации по регулировке
величин смещения и усиления модуля AL2-2TC-ADP см.
Руководстве по программированию контроллера серии
α2.
6. GENERAL SPECIFICATIONS
Table 4.
FRE Isolement
Aucune isolation entre les canaux (entrée ou
sortie) et l'alimentation en courant.
ITL Isolamento
Nessun isolamento fra I canali (enrata o
uscita) e alimentazione di corrente.
ESP Aislamiento
No existe aislación entre los canales (entrada
o salida) y la alimentación de corriente.
SWE Isolationskrets
Ingen isolering mellan kanalerna (in- och
utgång) och strömförsörjningen.
RUS Развязка
Развязка между каналами (вход/выход) и
цепью питания отсутствует
ENG Conversion
Characteristics
(Centigrade (°C))
(Fahrenheit (°F))
GER Wandlerkennlinie
FRE Caractéristique de
conversion
ITL Curva digitale
analogica
ESP Característica de
conversión
SWE Omvandlings-
karakteristik
RUS Характеристики
преобразования
Item Specification
ENG
Power Supply,
Max. Power Consumption
24V DC +20%, -15%, 1.0W
GER Spannungsversorgung
FRE Alimentation en courant
ITL Tensione alimentazione
ESP Alimentación en tensión
SWE Strömförsörjning
RUS
Источник питания,
максимальное
потребление
электроэнергии
Item Centigrade (°C) Fahrenheit (°F)
Digital
+450
-50
+450°C
(K-Type)
Temperature
+470
+470°C
-50°C
-70°C
-70
Digital
+8420
-580
+842°F
(K-Type)
Temperature
+8780
+878°F
-58°F
-94°F
-940
ENG
GER
FRE
ITL
ESP
SWE
RUS
ENG Operating Temperature
(-25) - 55°C / (-13) - 131°F
GER Betriebstemperatur
FRE
Température de
fonctionnement
ITL Temperatura di esercizio
ESP Temperatura de servizio
SWE Drifttemperatur
RUS Рабочая температура
ENG Storage Temperature
(-30) - 70°C / (-22) - 158°F
GER Lagertemperatur
FRE Température de stockage
ITL Temperatura di stoccaggio
ESP
Temperatura de
almacenamiento
SWE Förvaringstemperatur
RUS Температура хранения
ENG Humidity
35 - 85% Relative Humidity,
no condensation
GER Luftfeuchtigkeit
35 bis 85 % relative Luftfeuchtigkeit,
keine Kondensation
FRE Humidité
Humidité relative 35 – 85 %,
sans condensation
ITL Umidita
Umidita relativa 35-85%,
senza condensa
ESP Humedad
Humedad relativa 35-85%,
sin condensación
SWE Luftfuktighet
35–85 % relativ luftfuktighet,
icke kondenserande
RUS Влажность
Относительная влажность 35 - 85%,
без конденсата
ENG
Vibration Resistance
- DIN Rail Mounting
Conforms to IEC 68-2-6; 10-57Hz:
0.075mm Constant Amplitude
57-150Hz:9.8m/s
2
Acceleration. Sweep
Count for X, Y, and Z: 10 times (80 min-
utes in each direction
)
GER
Vibrationsfestigkeit
DIN-Schienen-Montage
Entspricht IEC 68-2-6; 10 – 57 Hz:
0,075 mm konstante Amplitude
57 – 150 Hz: 9,8 m/s
2
Beschleunigung.
Ablenkzyklus für X, Y, Z: 10 x (80 min. in
all 3 Richtungen)
FRE
Résistance aux vibrations
Montage sur rail DIN
Selon IEC 68-2-6; 10-57 Hz: 0,075 mm
amplitude constante
57-150 Hz: 9,8 m/s
2
accélération.
Nombre de balayages pour X,Y,Z: 10
fois (80 min. dans les 3 directions d’axe)
ITL
Resistenza vibrazioni
Montaggio su supporto DIN
Conforme alla normativa IEC 68-2-6;
10-57 Hz: 0,075 mm ampiezza
costante, 57-150 Hz: 9,8 m/s
2
accelerazione. Conteggio sweep per
X,Y,Z: 10 volte (80 min. in ogni
direzione)
ESP
Resistencia a las vibraciones
Montaje en raíl DIN
Conforme con IEC 68-2-6; 10-57 Hz:
0,075 mm amplitud constante, 57-150
Hz: 9,8 m/s
2
acceleración.
Conteo de barrido para X,Y,Z: 10 veces
(80 min. en cada dirección)
SWE
Vibrationstålighet
– montering på DIN-skena
Uppfyller IEC 68-2-6,10–57; Hz: 0,075
mm konstant amplitud, 57–150 Hz: 9,8
m/s
2
acceleration.
Svep i X, Y, Z: 10 gånger (80 minuter i
vardera riktningen)
RUS
Вибрационная
устойчивость при монтаже
на рельс DIN
Соответствует стандарту IEC 68-2-6;
10-57Гц: постоянная амплитуда
0,075мм
57-150 Гц: Ускорение 9.8м/с
2,
,
Количество размахов по всем трем
осям – 10 раз (80 минут в каждом
направлении).
ENG Shock Resistance
Conforms to IEC 68-2-27: 147m/s
2
Acceleration, Action Time: 11ms 3 times
in each direction X, Y and Z
GER Stoßfestigkeit
Entspricht IEC 68-2-27: 147m/s
2
Beschleunigung für 11 ms, 3 mal in alle
3 Richtungen X, Y und Z
Item Specification
FRE Résistance aux chocs
Selon IEC 68-2-27: 147m/s
2
accélération, temps d'action: 11 ms, 3
fois dans les 3 directions d’axe X,Y et Z
ITL Resistenza agli urti
Conforme alla normativa IEC 68-2-
27:147m/s
2
accelerazione, tempo di
azione: 11 ms, 3 volte in ogni direzione
X,Y e Z
ESP Resistencia al choque
Conforme con IEC 68-2-27: 147m/s
2
acceleración, tiempo de acción: 11 ms,
3 veces en cada dirección X,Y y Z
SWE Stöttålighet
Uppfyller IEC 68-2-27:147 m/s
2
acceleration under 11 ms, 3 gånger
vardera i riktningarna X, Y och Z
RUS Ударная устойчивость
Соответствует стандарту IEC 68-2-27:
Ускорение 147м/с
2
, длительность
воздействия: 11 мс 3 раза по каждой
оси.
ENG Noise Immunity
1000 Vpp 1µs, 30 - 100 Hz, tested by a
noise simulator
GER Störspannungsfestigkeit
1000 Vpp für 1µs, 30 - 100 Hz, getestet
mit Störspannungssimulator
FRE
Résistance aux tensions
parasites
1000Vpp, 1 microseconde, 30 - 100 Hz,
testé par simulateur de bruits
ITL Immunità al rumore
1000Vpp, 1 microsecondi, 30 - 100 Hz,
collaudato mediante simulatore di
rumore
ESP Inmunidad al ruido
1000Vpp, 1 microsegundo, 30 - 100 Hz,
probado por simulador de ruidos
SWE Brusokänslighet
1000 Vpp, 1 µs, 30–100 Hz, testat med
brussimulator
RUS Помехоустойчивость
1000 Впп 1мкс, 30 - 100 Гц,
протестировано с помощью
имитатора шумовых помех
ENG Dielectric Withstand Voltage
500V AC>1min per EN60730-1
between all terminals and the DIN43880
control box or equivalent.
GER Spannungsfestigkeit
500 V > 1 min nach EN60730-1
zwischen allen Klemmen und dem
Steuerkasten (DIN 43880) oder
Ähnlichem
FRE Rigidité diélectrique
500V CA > 1 min par EN60730-1 entre
toutes les bornes et le coffret (DIN
43880) et d’autres
ITL Rigidità dielettrica
500V AC > 1 min. come da norma
EN60730-1 tra tutti i morsetti e l’unità di
controllo DIN 43880 o equivalente
ESP
Resistencia a tensiones
eléctricas
500V CA > 1 min por EN60730-1 entre
todos los terminales y la caja de control
DIN 43880 ó sus equivalentes
SWE Genomslagsspänning
500 V >1 min enligt EN60730-1 mellan
alla plintar och DIN 43880
styrenhetsbox eller motsvarande
RUS
Напряжение
диэлектрической прочности
Напряжение ~500В, более 1 минуты,
по стандартуr EN60730-1,
напряжение ме
жду всеми клеммами
и шкафом управления по стандарту
DIN43880 или между
эквивалентными точками
ENG Insulation Resistance
7 M, 500V DC EN60730-1 between all
terminals and the DIN43880 distribution
box or equivalent.
GER Isolationswiderstand
7 M, 500 V DC nach EN60730-1
zwischen allen Klemmen und dem
Schaltschrank nach DIN 43880
FRE Résistance d’isolement
7 M, 500 V CC selon EN60730-1 entre
toutes les bornes et l'armoire électrique
selon DIN 43880
ITL Resistenza di isolamento
7 M, 500 V CC conf. EN60730-1 fra
tutti i morseti ed il quadro elettrico ad
armadio conf. DIN 43880
ESP Resistencia de aislamiento
7 M, 500 V CC según EN60730-1
entre todos los bornes y el armario de
distribución según DIN 43880
SWE Isolationsresistans
7 M, 500 V DC enligt EN60730-1
mellan alla klämmor och elskåpet enligt
DIN 43880.
Item Specification
RUS Сопротивление изоляции
7 MОм, при напряжении постоянного
тока 500В по стандарту EN60730-1,
напряжение между всеми клеммами
и распределительной коробкой или
между эквивалентными точками.
ENG Operation Ambience To be free of corrosive gases
GER Umgebungsbedingungen Frei von aggressiven Gasen
FRE Conditions ambiantes Sans gaz agressif
ITL Condizioni ambientali Ambiente privo di gas aggressivi
ESP Condiciones de entorno Libre de gases agresivos
SWE Driftmiljö Fri från korrosiva gaser
RUS
Рабочая окружающая
среда
Не должна содержать агрессивных
газов
Item Specification
1RWH7KLVV\PEROPDUNLVIRU&KLQDRQO\
ਜ਼ᴹᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘
ǂ
ᵜӗ૱ѝᡰਜ਼ᴹⲴᴹᇣ⢙䍘Ⲵ਽〠ˈਜ਼ᴹ䟿ˈਜ਼ᴹ䜘૱ྲл㺘
ᡰ⽪DŽ
ӝ૷ѣᴿᇩ⢟䍞Ⲻ੃〦਀੡䠅
ᵜ㺘Ṭ׍ᦞ6-7Ⲵ㿴ᇊ㕆ࡦDŽ
สҾѝഭḷ߶⌅Ⲵ৲㘳㿴Ṭ*%7
ƻ
㺘⽪䈕ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴਜ਼䟿൷൘*%7
㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
h㺘⽪䈕ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴਜ਼䟿䎵ࠪ*%7
 㿴ᇊⲴ䲀䟿㾱≲DŽ
䜞Ԭ੃〦
ᴿᇩ⢟䍞
3E
+J
䭿
&G
ޣԭ䬢
&U9,
ཐ⓪㚊㤥
3%%
ཐ⓪ӂ㤥䟐
3%'(
ཆ༣
ঠࡧสᶯ
㔗⭥ಘ
⭥㔶
ƻƻ
ƻƻ ƻ ƻ ƻ
ƻƻ ƻ ƻ
h
ƻh ƻ ƻ ƻƻ
ƻƻ ƻ ƻ ƻh
ɇ⭫ಞ⭫ᆆӝ૷ᴿᇩ⢟䍞䲆࡬ֵ⭞ḽ䇼㾷≸ɈⲺ㺞⽰ᯯᕅ
Manual Number : JY997D09501
Manual Revision : H
Date : June 2018
JY997D09501H
Effective June 2018
Specifications are subject to
change without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Mitsubishi Electric AL2-2TC-ADP Инструкция по установке

Тип
Инструкция по установке

Задайте вопрос, и я найду ответ в документе

Поиск информации в документе стал проще с помощью ИИ