APPA A1 Руководство пользователя

Категория
Измерительное, тестовое и контрольное оборудование
Тип
Руководство пользователя
Mini AC / DC Clamp Meter
迷你交流電 / 直流電鉤表
迷你交流电 / 直流电钩表
ミニ AC / DC クランプメーター
Клещи электроизмерительные
RU
EN
TC
SC
JP
User Manual / 使用說明書 / 使用说明书
ユーザーマニュアル
Руководство пользователя
A1
LIMITE D
WARRAN TY
YEAR S
A1 EN
Read First
Caution
Safety Information
Use the Meter only as specied in this
manual or the protection by the Meter might
be impaired.
- Always use proper terminals, switch position
and range for measurements.
- Verify the Meter’s operation by measuring a
known voltage. If in doubt, have the Meter
serviced.
- Do not apply more than the rated voltage,
as marked on Meter.
- To avoid false readings that can lead to
electric shock and injury, replace battery as
soon as low battery indicator blinks.
- Do not use Meter around explosive gas or
vapor.
- To reduce the risk of re or electric shock do
not expose this product to rain or moisture.
- Individual protective equipment should be
used if HAZARDOUS LIVE parts in the
installation where measurement is to be
carried out could be ACCESSIBLE.
Do not expose Meter to extremes in
temperature of high humidity.
1
A1 EN
Maintenance
Cleaning
Do not attempt to repair this Clamp Meter.
It contains no user-serviceable parts. Repair
or servicing should only be performed by
qualied personnel.
Periodically wipe the case with a dry cloth and
detergent. Do not use abrasives or solvents.
Symbols as marked on the Meter and
Instruction manual
Risk of electric shock
See instruction manual
DC measurement
AC measurement
Equipment protected by double or reinforced
insulation
Battery
Earth
Conforms to EU directives
Application around and removal from hazardous
live conductors is permitted
Do not discard this product or throw away
Read First
Safety Information
2
A1 EN
Power on/o
Auto Power O
Auto Power O Disable
Hold down and press
3
A1 EN
ACA & DCA
CAT. III 600V
with respect to
earth for the jaw
Do not hold
the meter across
the Barrier
Barrier for
Hand Guard
Auto ACA&DCA Detection / ACA&DCA
Dut to the high sensitivity of the clamp meter,
perform DCA Zero in the same direction
as measurement to avoid interference by
external magnetic eld.
CAT.III 600V
with respect to
earth for the jaw
Hand Guard
Barrier for
Do not hold
the meter across
the Barrier
4
A1 EN
Data Hold
The display will ash continuously if the
measured signal is larger 50counts than the
display reading. However, it cannot detect
across the AC and DC Current.
DCA ZERO
Inrush Current
The meter calculates the RMS value for
100ms as detecting a more than 5A current.
5
A1 EN
Low Pass Filter
The cut-o frequency of the low pass lter is
about 160Hz with attenuation characteristic of
approx-24db/octave.
Backlight on/o
Voltsense
Do not
hold the
meter across
the Barrier
Barrier for
Hand Guard
The number of dashes displaying on the LCD
indicates the electric eld intensity.
If no indication, voltage could still be present.
Data Hold
6
A1 EN
Battery Replacement
SPECIFICATIONS
1-1 General Specications
Display Count : 6000 count
Overrange Display : ”OL or “-OL”
Conversion Rate : 2 times / second
Dimensions (W x H x D) : 60 x 147 x 31.5
mm
Weight : 140 g
Power requirement : LR44 Size Button
Battery 1.5V x 2
Battery Life : 20 hours.
Maximum Conductor Size : 22 mm
LVD : EN61010-1, EN61010-2-032
EMC : EN61326-1
Installation category : CAT.III. 600V.
The circuits not connected to mains.
The circuits directly connected to Low
voltage installation.
The building installation.
The source of the Low-voltage installation.
Application eld
CAT
II
III
IV
I
7
A1 EN
1-2 Environmental Conditions
Indoor Use.
Maximum operating altitude : 2000m
(6562ft)
Operating temperature :
0°C ~ 30°C, ≤ 80%RH
30°C ~ 40°C, ≤ 75%RH
40°C ~ 50°C, ≤ 45%RH
Storage temperature :
-20 to +60°C, 0 to 80% RH (no batteries).
Temperature coecient :
0.2 x (Specied accuracy) / °C, < 18°C, >
28°C
Pollution Degree : 2
Shock vibration : MIL-PRF-28800F for A class
2 Instrument
Drop Protection :
4 Feet Drop to hardwood on concrete Floor
1-3 Electrical Specications
Accuracy is given as ±(% of reading + counts
of least signicant digit) at 23°C ± 5°C,with
relative humidity Less than 80% R.H. and is
specied for one year after calibration.
ACV and ACA specications are ac
coupled,true R.M.S. The crest factor may be
up to 3.0 as 4000 counts.
For non-sinusoidal waveforms, Additional
Accuracy by Crest Factor (C.F.):
Add 3.0% for C.F. 1.0 ~ 2.0.
Add 5.0% for C.F. 2.0 ~ 2.5.
Add 7.0% for C.F. 2.5 ~ 3.0.
Position Error of Clamp: ±1.5% of LCD
reading.
8
A1 EN
DC Current
(1) There are less than 0.3A variation as
measuring in dierent directions.
(2) Add 10D to accuracy in Auto AC & DC
Sense Mode.
60.00A (1) 0.01A
300.0A 0.1A ±(1.5%+5D)
±(1.5%+10D) (2)
Range Resolution Accuracy
AC Current
Frequency Response: 50 ~ 400Hz
(Sine Wave)
60.00A 0.01A
300.0A 0.1A
±(1.5% +25D)
for < 3A
±(1.5% +5D)
for ≥ 3A
±(2.5%+25D)
for < 3A
±(2.5%+5D)
for ≥ 3A
Range Resolution Accuracy
(50 ~ 100Hz)
Accuracy
(100 ~ 400Hz)
Low-pass Filter
Cut-o Frequency (-3dB) : Approx. 160Hz
Attenuation Characteristic : Approx. -24dB
/ Oct
60.00A 0.01A
300.0A 0.1A
±(3.5%+25D)
for < 3A
±(3.5%+5D)
for ≥ 3A
Range Resolution Accuracy
(50Hz/60Hz)
Inrush Current
Integration Time : 100ms
Trigger Current : 5.0 A
VoltSense
Voltage Range : 80V ~ 600V (At the tip of
clamp)
300.0A 300.0A
Range Resolution
9
A1 EN
Limited Warranty
This Meter is warranted to the original
purchaser against defects in material and
workmanship for 3 years from the date
of purchase. During this warranty period,
manufacturer will, at its option, replace or
repair the defective unit, subject to verication
of the defect or malfunction.
This warranty does not cover fuses,
disposable batteries, or damage from abuse,
neglect, accident, unauthorized repair,
alteration, contamination, or abnormal
conditions of operation or handling.
Any implied warranties arising out of the
sale of this product, including but not limited
to implied warranties of merchantability and
tness for a particular purpose, are limited
to the above. The manufacturer shall not
be liable for loss of use of the instrument or
other incidental or consequential damages,
expenses, or economic loss, or for any claim
or claims for such damage, expense or
economic loss. Some states or countries laws
vary, so the above limitations or exclusions
may not apply to you.
10
A1 TC
請務必閱讀
注意
安全性資訊
按照說明書使用儀表否則儀表的保護作用可
能會降低
- 務必以正確的端子開關位置和量程進行量測
- 請先量測已知電壓以確認儀表功能正常
有疑問請送修儀表
- 請勿施加超過儀表上註明的額定電壓
- 避免讀表錯誤進而導致觸電和受傷請在低電
量圖示開始閃爍時更換電池
- 請勿在爆炸性氣體或蒸氣周遭使用儀表
- 降低火災或觸電風險請勿將本產品暴露在雨
中或濕氣中
- 若在欲進行量測的安裝過程中可能會接觸危
險帶電零件應使用個人防護裝備
請勿在高濕度環境中將儀表暴露在極端溫度
下。
儀表上和說明書內的標誌
觸電風險
請參閱說明書
DC 量測
AC 量測
雙重或加強絕緣保護的設備
電池
接地
符合歐盟指令
可在危險帶電導體周遭使用及從其移開
請勿隨意丟棄本產品
11
A1 TC
開關機
自動關機功能
維護
清潔
請勿嘗試修理勾表
勾表並未內含使用者可自行維修的零件只有
符合資格的人員可進行修繕或維修工作
以乾布和清潔劑定期擦拭外殼請勿使用研磨
劑或溶劑
按住
按住
關閉
20 分鐘
超過 1 秒
12
A1 TC
自動關機功能
Hold down and press
關閉 不放並按下
按住
ACA & DCA
CATIII 600V
鉗頭接地
手握量表時
勿超過擋板
護手擋板
CAT.III 600V
with respect to
earth for the jaw
Hand Guard
Barrier for
Do not hold
the meter across
the Barrier
13
A1 TC
自動 ACA&DCA 偵測/ ACA&DCA
資料保留
由於電流鉤表的高靈敏度在量測時必須在相
同方向執行 DCA 歸零以避免受到外部磁場的
干 擾。
若量測的訊號大於螢幕讀數 50 計數螢幕就會
持續閃爍然而儀表無法偵測超過 AC 和 DC
電流的訊號
自動
按住
按住
按住
保留
按住
保留
超過 1 秒
保留
14
A1 TC
DCA 歸零
湧浪電流
儀表在偵測到大於 5A 電流時會計算 RMS 值
100ms
按住
湧浪
LPF
湧浪
輸入電流 >5A
按住 超過
2 秒
LPF
湧浪
低通濾波器
低通濾波器的截止頻率約 160Hz衰減率約每
倍頻程 -24dB
按住 LPF
湧浪
15
A1 TC
開啟/關閉背光功能
更換電池
Voltsense
手握量表
請勿超過
擋 板。
護手擋板
LCD 顯示的斜槓數量代表電場的強度
若未顯示也可能存在電壓
按住
16
A1 TC
規格
1-1 基本規格
顯示計數
6000 計數
超壓顯示OL」或「 -OL
轉換速率
2 次/秒
尺 寸( x x ): 60 x 147 x 31.5 mm
重 量:140g
電力需求
LR44 尺寸鈕扣電池 1.5V x 2
電池壽命
20 小 時。
最大導體尺寸
22mm
LVD
EN61010-1
EN61010-2-032
EMC
EN61326-1
安裝類別端子 CAT.III.600V
未連接電源的電路
應用領域
CAT
II
III
IV
I
直接連接到低電壓設備的電路
建築設備
低電壓設備電源
1-2 環境條件
室內使用
最高操作海拔2000m (6562ft)
操作溫度
0° C ~ 30° C≤ 80%RH
30° C ~ 40° C≤ 75%RH
40° C ~ 50° C≤ 45%RH
存放溫度
-20 到 60° C0 到 80% RH無安裝電池)
溫度係數
0.2 x ( 指定準確度 ) / ° C < 18° C 或 > 28° C
汙染等級2
衝擊振動符合 MIL-PRF-28800F 2 級儀器
防摔保護 4 英尺硬木和水泥地防摔
17
A1 TC
1-3 電氣規格
溫度 23° C ± 5° C 且相對溼度低於 80% R.H.
準確度 ±(% 讀值 + 最低有效位數 )並於
每年校準後重新提供
ACV 和 ACA 規格值為交流耦合且為真有效值
計數為 4000 時峰值因數可高達 3.0
不同非正弦波峰值因數 (C.F.) 需另加的準確度
誤 差:
C.F. 1.0 ~ 2.0 時應再加 3.0%
C.F. 2.0 ~ 2.5 時應再加 5.0%
C.F. 2.5 ~ 3.0 時應再加 7.0%
鉗夾位置誤差LCD 讀數的 ±1.5%
DC 電流
(1) 在不同方向量測時有小於 0.3A 的變化
(2) 在自動 AC & DC 感測模式中準確度加 10D
60.00A (1) 0.01A
300.0A 0.1A ±(1.5%+5D)
±(1.5%+10D) (2)
量程 解析度 準確度
AC 電流
頻率響應50 ~ 400Hz
(正弦波)
60.00A 0.01A
300.0A 0.1A
±(1.5% +25D) 適
用於 < 3A
±(1.5% +5D) 適用
於 ≥ 3A
±(2.5% +25D) 適
用於 < 3A
±(2.5% +5D) 適
用於 ≥ 3A
量程 解析度 準確度
(50 ~ 100Hz)
準確度
(100 ~ 400Hz)
低通濾波器
截止頻率 (-3dB)大約 160Hz
衰退特性大約每倍頻程 -24dB
60.00A 0.01A
300.0A 0.1A
±(3.5% +25D) 適用於
< 3A
±(3.5% +5D) 適用於 ≥
3A
量程 解析度 準確度
(50Hz/60Hz)
18
A1 TC
湧浪電流
積分時間100ms
觸發電流5.0A
電壓偵測
電壓量程80V ~ 600V於鉗頭尖端)
300.0A 300.0A
量程 解析度
有限保固
儀表的原購買者享有自購買日起算 3 年的保固
期間內的材料或工藝瑕疵均適用於保固期
製造商得於確認瑕疵或故障後選擇是否換
新或修理有瑕疵的產品
本保固服務不包含保險絲拋棄式電池或因濫
疏忽意外擅自維修或更換汙損或異常
操作狀況或處理動作造成的損壞
銷售本產品所衍生的默示保固包括但不限於
適銷性和適用於特定目的的默示保固僅限於
上述保固事項就儀器使用權喪失或其他附帶
或衍生性損害費用或經濟損失或對該損害
費用或經濟損失提出的任何求償製造商概不
負責由於部分州或國家的法律不同因此上述
限制或例外情況可能不適用於您
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

APPA A1 Руководство пользователя

Категория
Измерительное, тестовое и контрольное оборудование
Тип
Руководство пользователя

Задайте вопрос, и я найду ответ в документе

Поиск информации в документе стал проще с помощью ИИ

на других языках