The instructions contained in this manual give important
regarding security for installing and maintaining the
appliance. The manufacturer recommends that this
manual be carefully stored in the work zone where it can
be consulted by technicians and workers.
Gas connection of the appliance must be according to
the instructions given in table “T1”.
Disrespect of the instruction given by producer with the
appliance (Use, maintenance, gas connectin, technical
data table and data plate) may compromise the appliance
safety and will result in immediate loss of the warranty.
The manufacturer declines all responsibility for injury or
damage to persons or things, due to disrespect of the
instructions.
INSTALLATION
Positioning
The appliance should be placed under an exhaust hood
to remove smoke and smell which may occur during
the cooking process.
Position the appliance at least 10 cm from surrounding
walls. This distance may be reduced if the walls are
flameproof or protected by insulating material.
Assembly (Fig.-1)
Remove the protective nylon on the appliance. If sticky
particles left on the appliance, clean them with a suitable
solvent.
If you will use the appliance with cupboard, use
reference pins to put the appliance on cupboard and set
the balance of unit with foot(4 pcs.) on flat floor.
If you will use the appliance on support leg system, use
reference pins to put the appliance on leg system.
If you will use the appliance on working table, use
plastic foot at the bottom of appliance and drill a hole
for discharge of bain marie.
In the case of cantilever installations, refer to the
corresponding instructions.
Joining appliances together in line (Fig. 2)
Place the appliances side by side and level to the same
height.
Join the appliances by use of the special fixing holes on
the side of the fryer.
Connection to the gas supply
Before making the connection consult the gas supplier.
Gas inlet can be made from under or behind the
appliance.
Install a fast closing stopcock in an easily accessible
position upline from the appliance.
Confirm the absence of leaks at the points of connection.
Confirm that the appliance is suitable for the type of gas
with which it will be supplied. If not, read the paragraph
“Modification for other type of gas”.
All pieces needed for montage will be supplied by
manufacturing company.
Gas flex and gas hose connections must be carried out in
accordance with TS EN 14800 standard.
MODIFICATION FOR OTHER TYPE OF GAS
The appliance has been adjusted to operate with 30mbar
LPG(G30).
To adapt the appliance to another type of gas, carry out
all the operations set out below.
The nozzles, the minimum screws of the gas taps which
control the cooktop burners and the adhesive labels, are
contained in a bag supplied with the appliance.
Replacement of burner injector (Fig.3)
Remove the front control panel.
Unscrew the injector “E” from injector connection part
“A”.
Choose a suitable injector indicated in table “T2”.
Screw the new injector to injector connection part “A”.
Adjusting Burner air (Figure-3)
Ignite the main burner and set the control button to max.
stage.
Loosen screw "C" ve and move the sleeve "B" göre back
and forth according to the type of gas to ensure an ideal
combustion of the gas flame.
Retighten screw "C".
The burner should be operated at the highest posituon
for a few minutes, then set the control button to
minimum stage. Meanwhile, the burner should be at the
constant burning position.
In case the burner flame extinguishes or it's higher than
the normal burning it should be adjusted to get low
flame output by using "VM" adjustment screw which is
on the gas valve.(Figure-4)
Replacement of pilot burner injector(Fig-5)
Remove the front control panel.
Unscrew the connector "A" and substitute the injector
“B” with that indicated in table “T2”.
Screw in the connector "A".
WARNING : If the appliance is converted to a
different gas supply, affix the correct adhesive tag
indicating the new gas used.
SETTING UP
Operation check
Operation the appliance in accordance with the
instructions for use, check the correct lighting of the
burners, cheek the appliance for gas leaks and make sure
the gas exhaust system functions correctly.
If necessary, consult the " Typical Malfunctions" below.
Checking the nominal heat input
The appliance's nominal heat input must always be
checked following installation and conversion to a
different gas supply, and also after servicing.
The appliance's nominal heat input is indicated in Table
“T1”.
The nominal heat input is correct when the appliance is
fitted with the appropriate injectors for the type of gas