16
CAUTION: Avoid potential personal
injuries and property damage!
● Studs must be at least 2x4 in. (51 mm x 102 mm)
/ 25 ga. (0.6 mm)
● Stud type and structural strength must
conform to the North American Specification
for the Design of Cold-Formed Steel
Structural Members
[362 S 125 18, C-Shape, S - Stud Section].
● If back side of wall is unfinished, drywall must be
installed to a minimum of one stud left and right
of the stud(s) being used to install the mount.
● Drywall must be a minimum of 1/2 in. (13mm)
thick on each side of the studs, and a minimum
clearance of 1⅞ in. (48 mm)
behind the wall is required.
● Drywall must be secured to studs with
screws 12 in. (304.8 mm) on center.
● This product must be centered on the studs.
Min.
1/2 in.
(13 mm)
1
2
1. Locate stud.
2. Level the wall plate
07
and mark the hole locations.
Steel Stud Anchor Kit SSMK1 is not included
(see page 7) Contact
Customer Service: 800 359 5520 • EMEA: +31 (0) 800 056 2853 • UK: 0800 056 2853
to inquire about the additional hardware.
07
STEP 2C
Attach Wall Plate to Wall
Steel Stud Installation