ENGLISH Instructions for use Page 4
РУCCКИЙ
Инcтpyкции по экcплyaтaции Cтpaницa
17
AMD 081 - 082 - 084
4
SAFETY PRECAUTIONS
Do not install the appliance if it is connected to
the power supply.
The Installation and service/repair must be
performed by a qualified technician, in
compliance with the producer's instructions and
following local safety norms. Do not repair or
replace any parts of the appliance unless it is
specifically written in the user instructions.
The grounding of this appliance is compulsory.
Make sure that the power supply cord is long
enough to allow the right connection. Do not
use any extension cord for power supply.
Do not pull the power supply cord to remove it
from the socket.
Do not twist or press the power supply cord,
and make sure it is not broken.
Once installation is completed, the electric
components must not be accessible to the users.
Do not touch the operation buttons when your
hands are wet and don't use the appliance when
you are barefoot.
Physically or mentally disabled people, children
and people without any experience with the
product are only allowed to use the appliance if
they have had specific training on how to
operate the appliance by a person responsible
for their security and well-being. The appliance
is not intended for use by disabled people and
very young children without supervision.
AIR CONDITIONER PRECAUTIONS
Please strictly follow the below instructions:
Long and direct exposure to cool air might be
harmful to health. It is advisable to set the
louvers in order to avoid direct cool air and
deflect it within the room.
Prevent the air flow from reaching the gas
burners and stoves.
Upon malfunctioning first turn the appliance off
by pressing the ON/OFF button on the remote
control, then disconnect it from the mains.
This product contains Fluorinated Greenhouse
Gases covered by the Kyoto Protocol, the
refrigerant gas being in a hermetically sealed
system. Refrigerant gas: R410a has a Global
Warming Potential (GWP) 1975.
This appliance has been made of recyclable or
re-usable material. Scrapping must be carried
out in compliance with local waste disposal
regulations. Before scrapping it, make sure to
cut off the mains cord so that the appliance
cannot be re-used.
For more detailed information on handling and
recycling of this product, contact your local
authorities who deal with the separate collection
of rubbish or the shop where you bought the
appliance.
SCRAPPING OF PACKAGING
The packaging can be 100% recycled as
confirmed by the recycling symbol . The
various parts of the packaging must not be
dispersed in the environment, but must be
scrapped in line with local authority regulations.
SCRAPPING OF APPLIANCE
This appliance is marked according to the
European Directive 2002/96/EC, Waste
Electrical and Electronic Equipment (WEEE).
By ensuring that this product is disposed of
correctly, you will help to prevent potentially
negative consequences for the environment and
for human health.
The symbol on the product or on the
documents accompanying the product indicates
that this appliance should not be treated as
household waste, but must be given to the
appropriate local gathering place where electric
and electronic appliances are stored and
recycled.
SAFEGUARDING THE ENVIRONMENT
STARTING YOUR PORTABLE
AIR CONDITIONER
This section explains proper portable air
conditioner operation.
IMPORTANT:
The air conditioner display shows the current
room temperature and 24-hour clock.
When changing modes while the air conditioner
is operating, the compressor will stop for 3 to 5
minutes before restarting.
If a button is pressed during this time, the
compressor will not restart for another 3 to 5
minutes.
In Cooling or Dry mode, the compressor and
condenser fan will stop when the room
temperature reaches the set temperature.
NOTE: In the event of a power failure, your air
conditioner will operate at the previous settings
when the power is restored.
1. Select the mode. See "Mode."
2. Select the fan speed. See "Fan Speed."
3. Set the temperature. See "Temperature."
4. Press ON/OFF button to start the air
conditioner.
NOTE: When the air conditioner is turned on for
the first time after it is plugged in, it will run in the
6th Sense Mode control.
When the air conditioner is turned on at all other
times, it will run according to the previous settings.
6th Sense Mode can be selected with the remote
control only.
5. When WATER FULL indicator light glows red,
air conditioner will turn off automatically. See
"Portable Air Conditioner Care" for directions
on draining the air conditioner.
Timer
Swing
RapidCool
Adjust
Fan
Speed
Mode
On/Off
Filter
Reset
Wat e r
Full
On
Off
5
6
OPERATING MODE DESCRIPTION
Operating modes:
1. Press and release MODE until you see the
symbol glow for the desired setting
2. Choose Cooling, Dry or Fan Only.
Cooling-Cools the room. Press FAN SPEED to
select Auto, High, Mid or Low. Press the up or
down Adjust button to adjust the temperature.
Dry-Dries the room. The air conditioner
automatically selects the temperature. The fan
runs on Low speed only.
NOTE: Dry mode should not be used to cool the
room.
Fan Only-Only the fan runs. Press FAN SPEED
to select High, Mid or Low.
NOTE: Auto fan speed cannot be selected in Fan
Only mode.
Fan Speed
1. Press and release FAN SPEED to choose the
desired fan speed.
2. Choose Auto, High, Mid or Low.
Auto-automatically controls the fan speed
depending on the current room temperature
and temperature control setting.
NOTE: Auto fan speed cannot be selected in Fan
Only mode.
High-for maximum cooling
Mid-for normal cooling
Low-for minimum cooling
Filter Reset
1. When the Filter Reset indicator light is lit,
remove, clean and replace the air filter. See
"Cleaning the Air Filter."
2. Press and release FILTER RESET after replacing
the air filter.
NOTE: After 360 hours of fan operating time, the
Filter indicator light will turn on. It will remain on
for 180 hours or until you press FILTER RESET.
After 180 hours, it will turn off automatically.
Temperature
Press the up Adjust button to raise the
temperature. Press the up Adjust button once to
increase the set temperature by 1°C or press
twice to increase the set temperature by 2ºC.
Press the down Adjust button to lower the
temperature. Press the down Adjust button
once to decrease the set temperature by 1ºC,
or press twice to decrease the set temperature
by 2ºC.
NOTES:
In the Cooling mode, the temperature can be
set between 18ºC and 32ºC.
In Fan Only mode, the temperature cannot be
set.
To change the temperature display between ºC
and ºF, press both the up and down Adjust
buttons at the same time.
Clock function
You can adjust real time clock by pressing Timer
On and Timer Off buttons at same time on control
panel or Clock button on the remote. Press up or
down Adjusting button to get the correct time.
Press Timer On and Timer Off at the same time
again, and then the real time is set.
Timer On/Off
Set the real time to turn on the conditioner.
1. Press Timer On, Timer "On 12:00" indicator will
flash.
2. Press the up or down Adjust button to get your
desired time to turn on the appliance.
• Press the up or down Adjust button once to
increase or decrease the time setting by 1
minute.
• Press and hold the up or down Adjust button
for one and a half seconds to increase or
decrease the time setting by 10 minutes.
• Press and hold the up or down Adjust button
for a longer time to increase or decrease the
time setting by 1 hour.
3. When your desired time displayed on LCD,
press the TIMER ON button and confirm it,
then Timer "ON" indicator stops flashing and
your desired time remains on.
4. After your desired time displayed for 5 seconds,
the clock will be displayed on the LCD.
NOTE: If you don't set the time in 10 seconds
after you press TIMER ON button, the controller
will exit the TIMER ON mode automatically.
How to cancel Timer On
Press Timer On again, the indicator disappears and
the Timer On is canceled.
NOTE: It is similar to set Timer Off, you can make
the appliance unit switch off automatically at your
desired time.
Rapid Cool mode
Used for fast cooling. The air conditioner
automatically sets the fan speed to High and the
temperature to 18ºC.
NOTE: 6th Sense mode button does not operate
when Rapid Cool function is selected.
1. Press Rapid Cool. The air conditioner
automatically sets the fan speed to High and the
temperature to 18ºC.
2. To exit Rapid Cool mode press any button
except Timer On/Off and Swing button.
7
8
STORAGE AND TIPS FOR USING THE RC
How to insert the batteries
Remove the battery cover in the direction of the
arrow.
Insert new batteries making sure that the (+) and
(-) of battery are matched correctly.
Refit the cover by sliding it back into position.
Note:
Use 2 LR03 AAA (1.5volt) batteries. Do not use
rechargeable batteries.
Replace batteries with new ones of the same
type when the display becomes dim.
If the replacement is done within 1 minute, the
remote control will keep original presetting.
However, if you replace batteries taking more
than 3 minutes, all presetting will be cancelled
and timer will display Zero.
How to remove the batteries
Remove the battery cover in the direction of the
arrow.
Press the positive pole of the battery softly with
your fingers, then draw the batteries out of the
compartment.
All this should be done by adults, children are
forbidden to remove the batteries from the
remote control in order to avoid danger of
swallow.
Disposal of the batteries
Please discard the batteries as sorted municipal
waste at the accessible collection point.
USING THE REMOTE CONTROL
NOTE: Remote control may vary in appearance.
NOTES:
Two AAA batteries (included) power the remote
control. Replace batteries after 6 months of use,
or when the remote control starts to lose
power.
To operate the air conditioner with the remote
control, aim the remote control at the signal
receptor from no more than 23 ft (7 m) away.
Power On or Off
Press POWER.
Selecting mode
1. Press and release MODE until you see the
symbol glow for the desired setting.
2. Choose Cooling, Dry or Fan Only.
• Cooling-Cools the room. Press Fan to select
Auto, High, Mid or Low. Press the up or down
Adjust button to adjust the temperature.
• Dry-Dries the room. The air conditioner
automatically selects the temperature. Fan
runs on Low speed only.
NOTE: Dry mode should not be used to cool the
room.
• Fan Only-Only the fan runs. Press FAN to
select High, Mid or Low.
NOTE: Auto fan speed cannot be selected in Fan
Only mode.
9
FUNCTION DESCRIPTIONS
6th Sense mode
The air conditioner automatically selects Cooling
or Dry mode,depending on room temperature and
sets the target temperature.
Operation mode and temperature are determined
by indoor temperature.
Cooling only models
NOTE: Temperature, airflow and direction are
controlled automatically in 6th Sense mode.
However, a decrease or rise of up to 2°C can be
set with the remote control if you still feel
uncomfortable.
1. Press 6th Sense button.
2. In Fan Only mode, press Fan to select High, Mid
or Low.
Rapid Cool
Used for fast cooling. The air conditioner
automatically sets the fan speed to High and the
temperature to 18ºC.
NOTE: 6th Sense mode button does not operate
when Rapid Cool function is selected.
1. Press Rapid Cool. The air conditioner
automatically sets the fan speed to High and the
temperature to 18°C.
2. To exit Rapid Cool mode, press any button
except Timer On/Off and Swing button.
Fan Speed
1. Choose desired fan speed.
• Auto-automatically controls fan speed
depending on current room temperature and
temperature control setting.
NOTE: Auto fan speed cannot be selected in Fan
Only mode.
• High - for maximum cooling
• Mid - for normal cooling
• Low - for minimum cooling
Temperature
Press the plus button to raise the temperature.
Press the plus button once to increase the set
temperature by 1ºC, or press twice to increase
the set temperature by 2ºC.
• Press the minus button to lower the
temperature. Press the minus button to
decrease the set temperature by 1ºC, or
press twice to decrease the set temperature
by 2ºC.
NOTES:
In the Cooling mode, the temperature can be
set between 18ºC and 32ºC.
In Fan Only mode, the temperature cannot be
set.
Indoor
temperature
Operation
mode
Target
temperature
26°C or below DRY
Room
temperature
decrease 1.5°C
after operating
for 3 minutes
Over 26°C COOLING 26°C
10
Sleep mode
Press Sleep button on remote control, the
appliance operates in sleep mode and the fan speed
is automatically set to low speed.
NOTES:
In Cooling mode if the current room
temperature is 26ºC or higher the set
temperature will not change when Sleep mode is
activated, otherwise, the temperature will
automatically increase 1ºC during the first hour.
The set temperature will not increase during the
last 7 hours in Sleep mode.
1. Press MODE to select Cooling or Dry.
NOTE: Sleep mode cannot be selected when Fan
Only is selected.
2. Press Fan button .
3. Press the or button to set the
temperature.
4. Press SLEEP. After 5 seconds, the lights on the
control panel display will dim.
NOTES:
The temperature and airflow direction can be
adjusted during Sleep Mode.
To turn off Sleep mode, press MODE, ON/OFF,
6th SENSE, JET or SLEEP again or wait 8 hours
for the air conditioner to turn off automatically.
Changing Air Direction
On Remote Control or Control Panel
Press SWING once to change vertical airflow
direction. Press again to stop airflow louver at
desired airflow direction.
Normal Sounds
When your air conditioner is operating normally,
you may hear sounds such as:
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window
construction.
A high-pitched hum or pulsating noise caused by
the modern high-efficiency compressor cycling
on and off.
11
MAINTENANCE
Draining the Air Conditioner
(in accordance with the indication of Water Full
under "Starting your portable air conditioner".)
1. Press ON/OFF to turn off the air conditioner.
2. Unplug air conditioner or disconnect power.
3. Move the appliance gently and stably to a
draining location or outside to drain water. Do
not move the unit before water is drained out
completely.
4. Remove the secondary drain plug and drain
water completely.
5. Remove the primary drain hose from the drain
hose clip. Remove the drain hose plug from
the end of the primary drain hose and drain
water completely.
NOTE: If air conditioner will be stored after use,
see "Storing After Use."
6. Reinstall the drain hose plug and the secondary
drain plug.
7. Reattach the primary drain hose to the drain
hose clip.
8. Reposition the air conditioner.
9. Plug in air conditioner or reconnect power.
10. Press ON/OFF to start the air conditioner.
Cleaning the Air Filter
1. Press ON/OFF to turn off the air conditioner.
2. Open the filter panel door on the back of the
air conditioner and remove it.
3. Remove the air filter from the filter panel door.
4. Use a vacuum cleaner to clean the filter. If
filter is very dirty, wash filter in warm water
with a mild detergent.
NOTE: Do not wash filter in the dishwasher or
use any chemical cleaners.
5. Air dry filter completely before replacing to
ensure maximum efficiency.
6. Reattach the air filter to the filter panel door.
7. Reinstall filter panel door.
8. Press ON/OFF to start the air conditioner.
Cleaning the Outside
1. Unplug air conditioner or disconnect from
power.
2. Remove the air filter and clean separately. See
"Cleaning the Air Filter."
3. Wipe outside of the air conditioner with a soft,
damp cloth.
4. Plug in air conditioner or reconnect power.
5. Press ON/OFF to start the air conditioner.
Storing After Use
1. Drain the water (see the "Draining the Air
Conditioner")
2. Run the air conditioner set to Fan Only for
approximately 12 hours to dry the air
conditioner.
3. Unplug air conditioner.
4. Remove flexible exhaust hose and store with
air conditioner in a clean, dry area. See
"Installation Instructions."
5. Remove window kit and store with air
conditioner in a clean, dry area. See
"Installation Instructions."
6. Remove the filter and clean. See "Cleaning the
Air Filter."
7. Clean the outside of air conditioner. See
"Cleaning the Outside."
8. Reinstall filter.
9. Remove the batteries and store the remote
control with air conditioner in a clean, dry
area.
A. Secondary drain plug
B. Drain hose plug
C. Drain hose clip
D. Primary drain hose
A. Filter panel door
B. Air filter
12
TROUBLESHOOTING
Trouble Analysis
Air conditioner does
not operate
• The power supply cord is unplugged. Plug into a grounded outlet. See "Electrical
Requirements."
• A household fuse has blown, or a circuit breaker has tripped. Replace the fuse, or
reset the circuit breaker. See "Electrical Requirements."
• The On/Off button has not been pressed. Press ON/OFF.
• The local power has failed. Wait for power to be restored.
• Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace
with a time-delay fuse or circuit breaker of the correct capacity. See "Electrical
Requirements."
Air conditioner
blows fuses or trips
circuit breakers
• Too many appliances are being used on the same circuit. Unplug or relocate
appliances that share the same circuit.
• You are trying to restart the air conditioner too soon after turning off air
conditioner. Wait at least 3 minutes after turning off air conditioner before trying to
restart it.
• You have changed modes. Wait at least 3 minutes after turning off air conditioner
before trying to restart the appliance.
Air conditioner
seems to run too
much
• Is there a door or window open? Keep doors and windows closed.
• In cooling mode: the air conditioner is in a heavily occupied room, or heat
producing appliances are in use in the room. Use exhaust vent fans while cooking
or bathing and try not to use heat producing appliances during the hottest part of
the day. Portable air conditioners are designed as supplemental cooling to local
areas within a room. A higher capacity air conditioner may be required, depending
on the size of the room being cooled.
Air conditioner runs
for a short time
only, but room is
not cool
• Set temperature is close to room temperature. Lower set temperature. See
"Operating mode description".
Air conditioner
runs, but does not
cool
• The filter is dirty or obstructed by debris. Clean the filter.
• Air outlet is blocked. Clear air outlet.
• The setting temperature is not compatible. In cooling mode: set temperature is too
high. Lower set temperature.
Air conditioner
cycles on and off
too much
• The air conditioner is not properly sized for your room. Check the cooling/heating
capabilities of your portable air conditioner. Portable air conditioners are designed
as supplemental cooling/heating to local areas within a room.
• The filter is dirty or obstructed by debris. Clean the filter.
• In cooling mode there is excessive heat or moisture (open container cooking,
showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room.
Try not to use heat-producing appliances during the hottest part of the day.
• The louvers are blocked. Install the air conditioner in a location where the louvers
are free from curtains, blinds, furniture, etc.
• The outside temperature is below 18°C. Do not try to operate your air
conditioner in the cooling mode when the outside temperature is below 18°C.
Before calling for service, try the suggestions below to see whether you can solve your
problem without outside help.:
13
Location Requirements
NOTES:
The flexible exhaust hose allows placement of
the air conditioner between 23¹⁄ " and 64"
(60 cm and 163 cm) from window or door.
Portable air conditioners are designed as
supplemental cooling to local areas within a
room.
To ensure proper ventilation, keep the required
distance from the return air outlet to the wall or
other obstacles at least 23¹⁄ " (60 cm).
Do not block air outlet.
Provide easy access to grounded outlet.
Electrical Requirements
The portable air conditioner should be
connected to a 220-240V / 50Hz, 20-amp fused
grounded outlet.
The use of a time-delay fuse or time-delay
circuit breaker is recommended.
All wiring must comply with local and national
electrical regulations and be installed by a
qualified electrician. If you have any questions,
contact a qualified electrician.
Use your power supply cord:
Plug power supply cord into a grounded outlet.
NOTES:
A damaged power supply cord must be replaced
with a new power supply cord obtained from
the product manufacturer and must not be
repaired.
INSTALLATION REQUIREMENTS
14
Unpack the Air Conditioner
Remove packaging materials
Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before
turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your
fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or
glue. These products can damage the surface of your air conditioner.
Install Portable Air Conditioner
Install Exhaust Hose and Adapter
1. Roll air conditioner to selected location. See
"Location Requirements."
2. Insert hose adapter into slot on the back of air
conditioner.
3. Slide down to lock hose into place.
4. open the window, place the window exhaust
nozzle to the window down to lock hose into
place.
5. Extend the Exhaust hose and close the window
as much as possible to trap the exhaust nozzle as
below shown.
INSTALLATION INSTRUCTIONS
A. Evaporator air intake
B. Hose adapter
C. Flexible exhaust hose
D. Window exhaust adapter
15
INDOOR
INDOOR
Open Type window
INDOOR
Vertical Slide Window
INDOOR
Horizontal Slide Window
AFTER SALES SERVICE
Before contacting the Customer Care Centre:
1. Try to solve the problem yourself based on the
descriptions given in the "Troubleshooting".
2. Turn the appliance off and restart it to see if the
fault persists.
If after carrying out the above checks, the
fault persists, contact the Customer Care
Centre.
Please give:
a short description of the fault;
the exact model of the air conditioner;
the service number (this is the number found
after the word Service on the rating plate),
located on the back of the appliance. The
service number can also be found in the
warranty booklet;
your full address;
your telephone number.
If repair work has to be carried out, contact the
Customer Care Centre (Use of original spare
parts and a proper repair is guarenteed).
You will need to present the original invoice.
Failure to comply with these instructions
could compromise the safety and quality of
your product.
16
17
МЕРЫ ПРЕДОСТОРОЖНОСТИ
Не устанавливайте устройство, если оно
подключено к источнику питания.
Установка и обслуживание / ремонт должен
выполняться квалифицированным
специалистом, в соответствии с инструкциями
производителя и следуя местным нормам
безопасности. Ремонт и замена каких-либо
частей устройства предусмотрена только в
случае, если это специально указано в
инструкции пользователя.
Заземление этого устройства является
обязательным.
Убедитесь, что шнур электропитания является
достаточной длинны, чтобы обеспечить
правильное подключение.
Не используйте удлинитель для блока
питания.
Не тяните за шнур электропитания, чтобы
выдернуть его из розетки.
Не скручивайте и не давите на шнур
электропитания и убедитесь, что он не
сломан.
После того как установка будет завершена,
электрические компоненты не должны быть
доступны для пользователей.
Не прикасайтесь к операционным кнопкам
мокрыми руками, и не используйте
устройство, когда вы босиком.
Физически или умственно неполноценным
людям, детям и людям без какого-либо опыта
работы с продуктом разрешается
использованием устройства только в том
случае, если они прошли специальную
подготовку по вопросам эксплуатации
устройства у человека, ответственного за их
безопасность и благополучие. Устройство не
предназначено для использования
инвалидами и очень маленькими детьми без
присмотра.
МЕРЫ ПРЕДОСТОРОЖНОСТИ ПРИ
ИСПОЛЬЗОВАНИИ КОНДИЦИОНЕРА
ВОЗДУХА
Пожалуйста, строго следуйте ниже
приведенным инструкциям:
Длительный и прямой контакт с холодным
воздухом может быть вреден для здоровья.
Желательно установить жалюзи, чтобы
избежать прямого воздействия холодного
воздуха и направить его в комнату.
Не допускайте достижения воздушного
потока газовой горелки и плиты.
При неисправности в первую очередь
выключите устройство, нажав кнопку ON /
OFF на пульте дистанционного управления, а
затем отключите его от сети.
Этот продукт содержит фтористые
парниковые газы, согласно Киотскому
протоколу, охлаждающий газ находится в
герметически закрытой системе.
Охлаждающий газ: R410A имеет потенциал
глобального потепления (ПГП) 1975 года.
ВВОД ПОРТАТИВНОГО КОНДИЦИОНЕРА
В ЭКСПЛУАТАЦИЮ
В данном разделе описывается правильная
работа портативного кондиционера.
ВНИМАНИЕ:
На дисплее кондиционера отображается
текущая температура в помещении и суточные
часы.
При смене режимов в процессе работы
кондиционера компрессор остановится на 3-5
минут, после чего возобновит работу.
При нажатии на кнопку в этот момент
компрессор не будет работать в течение еще
3-5 минут.
В режиме Cooling (Охлаждение) или Dry
(Осушение) компрессор и вентилятор
конденсатора остановятся тогда, когда
температура в помещении достигнет заданной
температуры.
ПРИМЕЧАНИЕ: В случае перерыва в
энергоснабжении кондиционер возобновит работу
после восстановления энергии согласно
предыдущим настройкам.
1. Выберите режим. См. «Режим».
2. Выберите скорость вентиляции. См.
«Скорость вентиляции».
3. Задайте температуру. См. «Температура».
4. Для включения кондиционера нажмите на
кнопку ON/OFF (ВКЛ./ВЫКЛ.).
ПРИМЕЧАНИЕ: При первом включении
кондиционера после вставки вилки в розетку он
будет работать в режиме 6th Sense (6-е Чувство).
Во всех остальных случаях при включении
кондиционер начнет работу согласно
предыдущим настройкам. Режим 6th Sense (6-е
Чувство) можно выбрать только с помощью
пульта дистанционного управления.
5. Когда индикатор WATER FULL (ЗАПОЛНЕНИЕ
ВОДОЙ) загорается красным светом,
кондиционер автоматически выключается.
Для получения инструкций о дренаже
кондиционера обращайтесь к разделу
«Обслуживание портативного кондиционера».
Timer
Swing
RapidCool
Adjust
Fan
Speed
Mode
On/Off
Filter
Reset
Wat e r
Full
On
Off
18
Это устройство было сделано из материала,
пригодного для повторного использования или
материала многоразового использования.
Утилизация должна осуществляться в
соответствии с местными правилами
утилизации отходов. Перед утилизацией,
отрежьте сетевой кабель, чтобы устройство не
могло быть повторно использовано.
Для получения более подробной информации
по обращению и утилизации данного продукта,
свяжитесь с вашими местными органами
власти, которые занимаются сбором
раздельного мусора или с магазином, где вы
купили устройство.
УТИЛИЗАЦИЯ УПАКОВКИ
Данная упаковка может быть 100% повторно
использована, что подтверждается символом
утилизации . Различные части упаковки не
должны быть разбросаны в окружающей
среде, а должны быть утилизированы в
соответствии с правилами по утилизации
местных властей.
УТИЛИЗАЦИЯ ПРИБОРА
Данное изделие промаркировано в
соответствии с Европейской директивой
2002/96/EC по утилизации электрического и
электронного оборудования (WEEE).
Убедившись, что данный продукт
утилизируется правильно, вы поможите
предотвратить возможные негативные
последствия для окружающей среды и
здоровья человека.
Символ на продукте или документах,
сопровождающих продукт показывает, что это
устройство не должно рассматриваться в
качестве бытовых отходов, а должно быть
сдано в соответствующий местный пункт
сбора, где хранятся и утилизируются
электрические и электронные приборы.
СОВЕТЫ ПО ЗАЩИТЕ ОКPУЖАЮЩЕЙ
СPЕДЫ
19
ОПИСАНИЕ РАБОТЫ ПРИБОРА
Режимы работы
1. Нажмите кнопку MODE (РЕЖИМ) и не
отпуск5айте ее, пока не появится символ,
соответствующий нужной настройке
2. Выберите Cooling (Охлаждение), Dry
(Осушение) или Fan Only (Только вентилятор).
• Режим Cooling (Охлаждение) - Охлаждение
помещения. Нажмите кнопку FAN SPEED
(СКОРОСТЬ ВЕНТИЛЯТОРА) для выбора
скорости вращения вентилятора: Auto
(Автоматический выбор), High (Высокая), Mid
(Средняя) или Low (Низкая). Нажмите
кнопки регулировки Adjust со стрелками
вверх или вниз для задания нужной
температуры.
• Режим Dry (Осушение) - Осушение воздуха в
помещении. Выбор температуры
выполняется в кондиционере
автоматически. При этом вентилятор
работает только на низкой скорости (Low).
ПРИМЕЧАНИЕ: Не следует использовать режим
Dry (Осушение) с целью охлаждения воздуха в
помещении.
• Режим Fan Only (Только вентилятор) -
Работает только вентилятор. Нажмите
кнопку FAN SPEED (СКОРОСТЬ
ВЕНТИЛЯТОРА) для выбора нужной
скорости: High (Высокая), Mid (Средняя) или
Low (Низкая).
ПРИМЕЧАНИЕ: В режиме Fan Only (Только
вентилятор) опция Auto (Автоматический выбор)
недоступна.
Скорость вентилятора
1. Нажмите и отпустите кнопку FAN SPEED
(СКОРОСТЬ ВЕНТИЛЯТОРА) для выбора
нужной скорости вращения вентилятора.
2. Выберите одну из опций: Auto
(Автоматический выбор), High (Высокая), Mid
(Средняя) или Low (Низкая).
• Опция Auto (Автоматический выбор) -
Автоматический контроль скорости
вращения вентилятора с учетом текущей
температуры воздуха в помещении и
заданной в настройках температуры.
ПРИМЕЧАНИЕ: В режиме Fan Only (Только
вентилятор) опция Auto (Автоматический выбор)
недоступна.
• Опция High (Высокая) - максимальное
охлаждение
• Опция Mid (Средняя) - обычный уровень
охлаждения
• Опция Low (Низкая) - минимальное
охлаждение
Восстановление фильтра
1. Когда загорается индикатор Filter Reset
(Восстановление фильтра), необходимо
вынуть воздушный фильтр, прочистить его и
установить обратно на место. См. раздел
"Чистка воздушного фильтра".
2. После установки очищенного фильтра на
место нажмите и отпустите кнопку FILTER
RESET (ВОССТАНОВЛЕНИЕ ФИЛЬТРА).
ПРИМЕЧАНИЕ: Индикатор фильтра включается
по прошествии 360 часов работы вентилятора.
Он продолжает оставаться включенным в
течение 180 часов или до тех пор, пока не будет
нажата кнопка FILTER RESET
(ВОССТАНОВЛЕНИЕ ФИЛЬТРА). По истечении
180 часов этот индикатор автоматически
выключается.
Температура
• Нажимайте кнопку регулировки Adjust со
стрелкой вверх для увеличения
температуры. Нажмите один раз кнопку
регулировки Adjust со стрелкой вверх для
увеличения заданной температуры на 1°C
или два раза - для увеличения на 2°C.
• Нажимайте кнопку регулировки Adjust со
стрелкой вниз для уменьшения
температуры. Нажмите один раз кнопку
регулировки Adjust со стрелкой вниз для
уменьшения заданной температуры на 1°C
или два раза - для уменьшения на 2°C.
ПРИМЕЧАНИЯ:
В режиме Cooling (Охлаждение) температура
может задаваться в интервале от 18ºC до
32ºC.
В режиме Fan Only ("Только вентилятор")
температура не может быть задана.
Для переключения на дисплее между
градусами Цельсия и Фаренгейта нажмите
одновременно кнопки регулировки Adjust со
стрелкой вверх и со стрелкой вниз.
Функция часов
Установка текущего времени на часах
выполняется нажатием на панели управления
кнопок таймера Timer On и Timer Off
одновременно или кнопки Clock (Часы) на пульте
ДУ. Нажмите кнопки регулировки Adjust со
стрелками вверх или вниз для задания
правильного значения времени. Снова нажмите
одновременно кнопки таймера Timer On и Timer
Off: текущее время теперь будет задано.
Таймер включения/выключения
Задание нужного времени включения
кондиционера
1. Нажмите кнопку Timer On (Таймер
включения), при этом начнет мигать
индикация "On 12:00".
2. Нажимайте кнопки регулировки Adjust со
стрелками вверх или вниз до тех пор, пока на
дисплее не появится нужное время
включения прибора.
• Для увеличения или уменьшения
задаваемого значения времени на 1 минуту
однократно нажмите кнопку регулировки
Adjust со стрелкой вверх или вниз.
• Для увеличения или уменьшения
задаваемого значения времени на 10 минут
нажмите кнопку регулировки Adjust со
стрелкой вверх или вниз и и держите ее
нажатой в течение полутора секунд.
• Для увеличения или уменьшения
задаваемого значения времени на 1 час
нажмите кнопку регулировки Adjust со
стрелкой вверх или вниз и держите ее
нажатой более продолжительное время.
3. Когда на дисплее будет отображаться нужное
время, нажмите кнопку TIMER ON для
подтверждения выбора, при этом индикатор
таймера "ON" (ВКЛ) перестанет мигать, и
выбранное значение времени останется на
дисплее.
4. Выбранное время отображается на дисплее в
течение 5 секунд, после этого на дисплей
выводится текущее время.
ПРИМЕЧАНИЕ: Если после нажатия кнопки
TIMER ON в течение 10 секунд нужное время не
будет задано, то происходит автоматический
выход из режима включения таймера TIMER ON.
Отмена установки таймера включения
Нажмите кнопку Timer On снова, индикация
исчезнет, и работа таймера включения (Timer
On) будет отменена.
ПРИМЕЧАНИЕ: Настройка таймера выключения
(Timer Off) выполняется аналогично: прибор
может быть выключен автоматически в нужное
время.
Режим Rapid Coo
Используется для быстрого охлаждения. При
выборе этого режима в кондиционере
автоматически выбирается самая высокая
скорость вращения вентилятора (High) и
температура равная 18єC.
ПРИМЕЧАНИЕ: Режим "6th Sense" (6-е чувство)
недоступен (соответствующая кнопка не
работает) в случае, когда выбран режим Rapid
Cool.
1. Нажмите кнопку Rapid Cool. При выборе этого
режима в кондиционере автоматически
выбирается самая высокая скорость
вращения вентилятора (High) и температура
равная 18ºC.
2. Для выхода из режима Rapid Cool нажмите
любую кнопку (кроме кнопок Timer On/Off и
Swing).
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Whirlpool AMD 081 Руководство пользователя

Категория
Мобильные кондиционеры
Тип
Руководство пользователя

Задайте вопрос, и я найду ответ в документе

Поиск информации в документе стал проще с помощью ИИ

на других языках