  • Привет! Я прочитал руководство пользователя по трансмодуляторам TERRA ELECTRONICS моделей tdq420C, ttq420C, tdq420 и ttq420. Готов ответить на ваши вопросы об их настройке, функциях и технических характеристиках. В руководстве подробно описаны параметры RF входов и выходов, процесс обработки транспортного потока, настройка CAM модулей и многое другое.
  • Как настроить IP-адрес устройства?
    Какие типы LNB поддерживаются?
    Как настроить параметры RF выходов?
    Как обновить прошивку устройства?
1
Twin DVB-S/S2/S2X & DVB-T/T2/C to DVB-C/J.83B transmodulators
tdq420C, ttq420C, tdq420, ttq420 EN RU
Vers. 1.20
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN IEC62368-1, RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical
equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
1. Product description
The devices are transmodulators with two DVB-S/S2/S2X (tdq420C, tdq420), DVB-T/T2/C (ttq420C, ttq420) input channels
and two DVB-C/J.83B output channels. The devices are designed for digital transmodulation with Transport Stream Processing
of TV or Radio programmes issued from FTA (Free to air) or encrypted digital reception; in case of encrypted signal, the CAM
(Conditional access module) containing the operator's smart card must tted in the slot. Modules processor enables, services
ltering, modifying SI (Service Information), generating NIT (Network Information table), LCN (Local Channel Number),
restamping PCR (Program Clock Reference). All of the congurations can be changed by using the Web Interface.
tdq420C – transmodulator with two DVB-S/S2/S2X input channels and two DVB-C/J.83B output channels with two CAMs.
ttq420C – transmodulator with two DVB-T/T2/C input channels and two DVB-C/J.83B output channels with two CAMs.
tdq420 – transmodulator with two DVB-S/S2/S2X input channels and two DVB-C/J.83B output channels.
ttq420 – transmodulator with two DVB-T/T2/C input channels and two DVB-C/J.83B output channels.
Transmodulators can be used as stand alone devices.
The products are intended for indoor usage only.
2. Safety instructions
Installation of the transmodulator must be done according IEC60728-11 and national safety standards.
Any repairs must be made by qualied personnel.
Do not expose this transmodulator to moisture or splashing water and make sure no objects lled with liquids, such as
vases, are placed near or on the unit.
Avoid placing the transmodulator next to heat sources such as central heating components or in areas of high humidity.
Keep the transmodulator away from naked ames.
If the transmodulator has been kept in cold conditions for a long time, bringing it into a warm environment may cause
condensation, so allow it to warm up for no less than 2 hours before powering.
Ventilation should not be impeded by covering the transmodulator, such as newspapers, table-cloths, curtains etc.
Mount the transmodulator in a vertical position only. If installing in a 19” rack system additional forced air cooling fans
may be required (see table "Technical specications" - operating temperature range).
Always allow 10 cm of free space from the top, front and bottom of the unit to enable any heat to be dissipated.
EN
Manual in .pdf
2
3. External view
tdq420
tdq420C
Figure 1. External view of the transmodulators
1 - CA modules slots. Double PCMCIA sockets
(tdq420C, ttq420C).
1.1 - rst module CAM 1
1.2 - second module CAM 2
2 - - RF input of SAT IF signal, DC output for LNB
(tdq420C, tdq420);
RF input of terrestrial, cable signal, DC output for
preamplier (ttq420C, ttq420). F socket.
3 - ►- RF output (input signal loop-through). F socket.
4 - ETHERNET - control Ethernet interface. RJ45 socket.
5 - ACTIVITY (yellow) indicator of the control Ethernet
interface.
6 - LINK (green) indicator of the control Ethernet interface.
7 - RESET and default IP button.
Press button for more than three seconds to set default
IP address of the control Ethernet interface. Ethernet led
indicators "activity" [5] and "link" [6] will start to toggle
to inform, that the reset IP address request has been
accepted. Device will be restarted with default IP address.
To restore all parameters to default values (including
password), keep pressing the button for additional 4
seconds. The green (link) indicator will start blinking after
that time indicating, that a “restore defaults” command has
been accepted. Now the button can be released. Yellow
(activity) indicator will light on while resetting parameters.
After that device will restart with all default values.
8 - Power distribution bus connector.
9 - +12 V DC powering input. Screw terminal.
10 - RF input (output signal loop-through). F socket.
11 - RF output. F socket.
DC IN 12V
-
-
+
+
tdq420
RESET
ETHERNET
TERRA
2
3
5
6
4
7
10
11
tdq420
DC IN 12V
-
-
+
+
8
9
DC OUT 13/18V
1 A max
DC OUT 13/18V
1 A max
2
3
5
6
4
7
10
11
8
9
1
1.1 CAM 1 1.2 CAM 2
tdq420C
RESET
ETHERNET
DC IN 12V
-
-
+
+
DC IN 12V
-
-
+
+
tdq420C
TERRA
DC OUT 13/18V
1 A max
DC OUT 13/18V
1 A max
3
4. Installation instructions
Read the safety instruction rst.
All settings can be changed using the web browser via control Ethernet interface.
Disconnect power supply unit from the mains before making any changes in the connections of the module. Fasten the
module on DIN RAIL or individual holder. Connect all necessary RF, powering and control cables. Shielded Ethernet cable
is recommended.
Connect the 75 W load to the unused RF output F sockets.
Insert CA modules.
Connect power supply in to the mains.
Within 5-40 seconds of powering the module will run in normal operation mode.
Comments of the front panel indicators:
if the link with the control Ethernet interface is established - the LINK [6] indicator glows;
the ACTIVITY [5] indicator blinks, if communication via the control Ethernet interface is active.
5. MOUNTING
The module or mounting bracket must be xed with steel screws Ø 3.5-4 mm. The screws are not included in a package.
Mounting bracket on DIN rail should be connected to main potential equalization bus.
Mounting on a wall by screws Mounting on a bracket (ordering number 01960)
Perpendicular to the wall Parallel to the wall
Figure 2. Mounting of the transmodulator
Package contents
1. Transmodulator ............................................................. 1 pcs.
2. Spacer .......................................................................... 1 pcs.
3. 75 W terminator ............................................................. 1 pcs.
4. Bridge F quick to F quick .............................................. 1 pcs.
5. User manual ................................................................ 1 pcs.
Requirements for external power supply unit
• Output voltage +12 V ± 0.5 V
• Ripple at single and/or double mains frequency < 10 mV p-p
• Ripple & noise < 100 mV p-p
• Short circuit protection
• Double insulated (marked )
• Meet EN 55022 class B conducted emisions requirements, measuring with grounded load
4
1. 2.
Mounting on DIN rail
Figure 5. Mounting or removing to/from
DIN rail of plastic spacers (supplied).
Figure 3. Mounting to DIN rail
Figure 4. Mounting from DIN rail
DC IN 12V
-
-
+
+
TERRA
RESET
ETHERNET
tdq420
DC IN 12V
-
-
+
+
TERRA
RESET
ETHERNET
tdq420
DC IN 12V
-
-
+
+
TERRA
RESET
ETHERNET
tdq420
5
6. Operating
6.1 Initial conguration
All modules leave the factory with this control over Ethernet interface IP address: 192.168.1.10. In order to avoid conicts
with other IP addresses, it is necessary to perform an initial conguration in the local mode. Subsequently, it will be possible
to access the module via local area network (LAN), either to change the conguration or to check the operating status.
The modules leave the factory with the following control over Ethernet interface TCP/IP conguration:
IP address of the module: 192.168.1.10
Subnet mask: 255.255.255.0
Default Gateway: 192.168.1.1
To access each module, use a personal computer (PC) equipped with an Ethernet card and
RJ-45 cable (CAT-5E or CAT-6). The IP address of the PC/MAC must be congured within
the following range: 192.168.1.2 - 192.168.1.254 (do not use 192.168.1.10, since this is the
IP address of the module to be congured). To start the conguration of the module, open
your web browser and type in the following direction: http://192.168.1.10. The login prompt
will appear on the screen (see Figure 6).
Figure 6. Login window
Access to the module is protected by user name and password. The default user name and password is admin. Enter
the user name and password and click on "Login" button.
NOTE*: the default password - admin - can (and must) be changed as explained in the section 6.11.5 "User management".
During initial conguration you need to change the default control interface TCP/IP conguration as explained in the section
6.8 "IP settings".
NOTE**: If you are using Internet Explorer Web browser, supported versions are version 10 or higher.
Control interface IP address reset to default procedure: press the "RESET" [7] button for more than 3 seconds and release
it. After this operation the control interface IP address will be set to 192.168.1.10, for more information see section 6.8.
6.2 General conguration
Initial Web interface screen
The rst screen that appears when the module accessed is the "Main" window, which gives general information on the
device.
Figure 7. General information screen
In the top of each conguration screen you will see a main menu tabs [1]. Using it, you can switch between the dierent
conguration menu. The tab highlighted in yellow shows which menu is active at a given moment. The "System menu" tab
contains several submenu items. Also common elements for all screens are module title [2] and login information strings
[3]. The module title can be changed after pressing the "Change" button in the "Device information" table. Pressing on the
"Logout" string you can logout from module control.
[1]
[2]
[3]
6
Device information table
This shows the following data of module:
“Device model”: model of the module.
“Serial number”: serial number of the module.
“Software version”: module software version number.
“System time”: current time, synchronized from the TDT table of the input stream or NTP server. Local time oset can be
selected in the "IP settings" tab, see section 6.8 "IP settings".
“Up time”: time passed from last power-up or restart of the module.
Output bitrates table
It displays the output bitrate status of each channel in real time, Horizontal bar shows the percentage of used available
bandwidth in the channel. The 1st number right to the bar shows actual bitrate in Mbps. Next number shows maximum allowed
bitrate in the channel and it depends on modulation parameters. Ensure that actual bitrate would not reach more than 95%
of available bandwidth. Otherwise bitrate overow may occur.
System status table
It represents the following parameters at real time: Processor load in percents, internal temperature in degrees of Celsius,
power voltage in Volts.
Other device in the network
If there are any modules in the network their status and diagnostic information will be displayed as it is in Figure 7 "General
information screen". If modules status is red press the down arrow and diagnostic errors will be displayed. Make sure, that
Ethernet router is congured properly to pass SSDP packets (239.255.255.250:1900 and 239.255.255.246:7900). Also make
sure that all modules are connected to the same Ethernet network
Diagnostic information table
It displays all module errors and comments how to eliminate them.
Figure 8. Diagnostic information table with errors
6.3 RF inputs
Figure 9. "Input 1" table (DVB-S/S2/S2X input only) Figure 10. "Input 1" table "Source types = dSCR"
The Figure 9 "Input 1" table in modules with DVB-S/S2/S2X input consists of the following parameters:
"LNB LO frequency" - the LNB local oscillator lower frequency in megahertz. Use 9750 MHz for the universal converter.
"LNB HI frequency" - the LNB local oscillator upper frequency in megahertz. Use 10600 MHz for the universal converter.
“LNB Power” - power supply of the converter – can be set to “0”, “13V”, “18V”, “13V/22kHz”, “18V/22kHz”.
"Polarization" - the polarization of converter. Can be "Horizontal" or "Vertical".
“Source type” - the LNB types, there are several: Universal, Quadro, DiSEqC, dSCR EN50607, SCR EN50494 - see Figures
9, 10.
7
“Universal LNB” - power supply voltage of the converter is chosen according
to the selected polarization 18 V Horizontal, 13 V Vertical; the 22 kHz is
set depending on given "LNB HI frequency" "LNB LO frequency" and “Input
frequency” parameters.
For example:
LNB Hi=10,600, LNB Lo=9750, then F=(950+10,600+2150+9750)/2=11,725
MHz.
“DiSEqC” - then DISEQC commands are used to select the satellite. Possible
commands: “Satellite A”, “Satellite B”, “Satellite C”, “Satellite D”, Vertical or
Horizontal polarization.
"dSCR" – first select source type as shown in Figure 10, then select
“dSCR/SCR mode“ Master or Slave (Master for module which has direct
connection to Unicable multiswitch or LNB and Slave for modules connected by
loop through). If Slave was selected, additionally type the IP address of Master
module. All the modules in the dSCR/SCR group must be in the same Ethernet
network. Next select "SAT input" and "User band", type in frequencies, symbol
rate press “Update” button and observe "dSCR" status.
"SCR" - same as "dSCR", just the user band frequencies must be typed in
manually as shown in Figure 11.
Figure 11. "Input 1" table "Source types = SCR"
Figure 12. Demodulator settings table (DVB-S/S2/S2X input only)
The Figure 12 "Demodulator settings table" in modules with DVB-S/S2/S2X input consists of the following parameters:
„SAT input“ - A parameter that can switch demodulator o or connect to any available RF input (Figure 13).
“User band” - parameter used in dSCR/SCR Switches.
„Input frequency“ - parameter is a frequency of transponder in MHz.
„Symbol rate“ - parameter is a symbol rate of transponder in kSym/s.
Figure 13. SAT input (DVB-S/S2/S2X input only)
For advanced "DVB-S2 options", press "Congure" link and "Advanced DVB-S2 parameters" will be displayed, see Figure 14.
8
“PLS" - Physical Layer Scrambling used in DVB-S2 as a way to improve data integrity. A number called the "scrambling
sequence index" is used by the modulator as a master key to generate the uplink signal. This same number must be known
by the receiver so that demodulation would be possible.
PLS mode - “Root“ or “Gold“.
Stream - parameter needed for multistream transponders.
NOTE: If advanced parameters is not needed make sure to leave them as shown in Figure 14.
Figure 14. "Advanced DVB-S2 parameters" tables (T2-MI deencapsulation is supported only in M.1 version)
NOTE: De-encapsulation of up to 2x T2-MI streams, the total streams bitrate must not exceed 50 Mbit/s.
New Feature "Congure TERRA dSCR system"
Before starting conguration please make sure that all multiswitches are
connected to module via splitter that lets DC through in both directions!
Press “Congure Terra dSCR system” and wait while the device scans all available
multiswitches. After scan nishes serial numbers and conguration will be displayed
(Figure 16).
Select “Total bands” count and SAT position (Figure 17).
Press “Congure” if you are using wideband multiswitches you will be able to change
the heterodyne frequency (Figure 18).
NOTE: Be aware when changing user band count you are also changing the maximum
bandwidth of transponder that you will be receiving.
Figure 15. "Input 1" table "Source types = dSCR"
Figure 16. Table "Congure SAT positions and total bands"
Figure 17. Table "Congure SAT positions and total bands" Figure 18. Table "Congure heterodyne frequency"
9
The Figure 19 "Demodulator settings table" in modules with DVB-T/T2/C input consists of following parameters: "Modulation
standard" - used to select from the "DVB-T/T2" and "DVB-C" modulation standards. "Preamplier power" - used to switch
on/o the power for the RF preamplier. "Input bandwidth" - the bandwidth of DVB-T/T2 transponder. Can be selected from
values 8 MHz and 7 MHz. "Input frequency" – the frequency of the terrestrial or cable transponder in MHz. Frequency step
is 0.1 MHz. When the tuner is locked to the DVB-T2 transponder with multi PLP modulation, the additional parameter "PLP
number" is displayed in the "RF input" table. When the "Modulation standard" is set to DVB-C, the „Preamplier power"
parameter is disabled and power for the RF preamplier is switched o; the "Input bandwidth" parameter is disabled and the
"Symbol rate" parameter is enabled. Enter the value in kilo symbols per second.
Figure 19. Demodulator settings table (DVB-T/T2/C input only)
Press „Update“ button to set new parameters
Input status table
The following information is displayed in the table “Input status”:
“RF level” - RF signal level at the module input. Level indication - approximate.
The values of the following parameters are displayed only if the module has synchronized
with the input signal.
“Modulation standard” - detected standard of the input signal. Possible values of the
standard: DVB-S, DVB-S2, DVB-S2X, DVB-T, DVB-T2, DVB-C
“Frequency” - intermediate frequency (for DVB-S/S2/S2X) or RF frequency (for
DVB-T/T2/C) at the module input.
“Modulation” - modulation scheme of the input signal. Possible values of the modulation
scheme: QPSK, 8PSK, 16APSK, 32APSK (for DVB-S/S2/S2X) QPSK, QAM16, QAM32,
QAM64, QAM128, QAM256 (for DVB-T/T2/C).
“Modulation mode” - OFDM modulation mode of the input signal (for DVB-T/T2/C)
Values: 8k or 2k.
“FEC” - forward error correction.
“Guard interval” - guard interval of OFDM signal (for DVB-T/T2/C).
“Symbol rate” - the symbol rate of the satellite transponder in kilo symbols per second
(tdq420C only).
“SNR” - RF signal/noise ratio at the input of module.
“VBER” - bit error rate after Viterbi corrector. To get the signal without any errors at the
output of the tuner, VBER shall not exceed 2Е-4.
“PER” - ratio of the MPEG2 transport error packets to the whole number of packets.
If the number of error packet is equal to zero, the opposite value to whole number of
packets is displayed. Packet counters are reset during RF input parameters update.
“Input bitrate” - bitrate of the input signal.
Figure 20. Status table (for DVB-S/S2/S2X)
10
6.4. Transport Streams
One channel at a time can be congured in this page. Select proper channel from the list at „Choose input channel“
combobox (see Figure 21 "Transport streams page").
Figure 21. Transport streams page
A list of services in the selected channel will appear. „List of services“ table shows a list of available services. Icon before
the service name indicates service type. Bitrate of each service is measured in real time. Services that currently are not
running will be displayed as grayed. They can be selected and will be outputted normally when the services starts to running.
„LCN“ eld is a Logical Channel Number. Every service can have a „channel number“ and TV will sort channels according to
it. Just ensure, that all services in all channels have dierent numbers. Value 0 means, that LCN for that service is not used
at all and TV will sort these channels according to it’s own rules. If channel numbers are added, but TV does not recognize
it, check the following:
- If TV supports LCN?
- If Network ID and Original Network ID values are valid for the country, which is selected on TV?
„Enable“ dropbox enables the service to the selected output.
“Descramble” checkbox enables or disables descrambling.
Press onto „+“ sign and service information will be extended (see Figure 22 "Service details").
Figure 22. Service details
“Service title“ and “Service provider“ can be edited (multilanguage character support). „Scrambled ag“ will be inserted
into SDT (Service Description Table). Unchecking this checkbox will not descramble the content. It only carries information
about the scrambling status of the service. “Descramble” checkbox enables or disables descrambling.
"Service type": this is an 8-bit eld specifying the type of the service. The assignment of service type value for a Service
is described in EN 300 468. It shall be coded according to Figure 23.
"Parental control": this selection enables ability to restrict certain content viewable by the user. For example, parental control
eld is set to "Less than 6 years", than all content with maturity rating above 6 years old will be ltered out.
Figure 23. Service type coding
11
Service type Description
0 reserved for future use
1 digital television service (see note 1)
2 digital radio sound service (see note 2)
3 Teletext service
4 NVOD reference service (see note 1)
5 NVOD time-shifted service (see note 1)
6 mosaic service
7 FM radio service
8 DVB SRM service [49]
9 reserved for future use
10 advanced codec digital radio sound service
11 H.264/AVC mosaic service
12 data broadcast service
13 reserved for Common Interface Usage (CENELEC EN 50221 [37])
14 RCS Map (see ETSI EN 301 790 [7])
15 RCS FLS (see ETSI EN 301 790 [7])
16 DVB MHP service
17 MPEG-2 HD digital television service
18 to 21 reserved for future use
22 H.264/AVC SD digital television service
23 H.264/AVC SD NVOD time-shifted service
24 H.264/AVC SD NVOD reference service
25 H.264/AVC HD digital television service
26 H.264/AVC HD NVOD time-shifted service
27 H.264/AVC HD NVOD reference service
28 H.264/AVC frame compatible plano-stereoscopic HD digital television service (see note 3)
29 H.264/AVC frame compatible plano-stereoscopic HD NVOD time-shifted service (see note 3)
30 H.264/AVC frame compatible plano-stereoscopic HD NVOD reference service (see note 3)
31 HEVC digital television service (see note 4)
32 to 127 reserved for future use
128 to 254 user dened
255 reserved for future use
NOTE 1: MPEG-2 SD material should use this type.
NOTE 2: MPEG-1 Layer 2 audio material should use this type.
NOTE 3: For information on the use of these values, see clause I.2.3 and ETSI TS 101 547-2 [54]
(3D Guidelines of Frame Compatible 3D-TV).
NOTE 4: For information on the use of these values, see clause I.2.5 and ETSI TS 101 547-4 [62].
12
Individual streams can be disabled as well. Also PID number can be remapped manually by selecting checkbox “Other
PID” (Keep in mind than PID must be unique) otherwise PID remapping is done automatically.
Press onto „Update“ button to save changes and execute.
NOTE: If transparent mode is selected, all services of transponder will be passed to the output, including original PAT, SDT,
PMT, EIT, CAT, NIT tables, all changes that were made to these tables will be disregarded. No more than 95% of output
bandwidth usage is recommended, otherwise overow might occur.
6.5. NIT
Several tables related to NIT generation exist in this section. Figure 24 "Global TS parameters" describes following TS
parameters:
Figure 24. Global TS parameters
“Network ID”: is unique number within the geographical region dened by the “country code”. For a cable network usually
this is a single country code plus 0x2000 (8192). If there are more connected modulators in the network, they must have
the same Network ID.
Proper value depending on your country and operator can be found here:
http://www.dvbservices.com/identiers/network_id?page=1
“Private data specier (hex)”: can be inserted in the NIT table for proper LCN description. This value is described in TS
101162 specication. NorDig standard requires 00 00 00 29 value, UK should use 00 00 23 3A value.
Other options can be found here:
http://www.dvbservices.com/identiers/private_data_spec_id?page=1
The parameter will not be inserted into NIT if value is set to zero.
„Network name“ is the name of the network.
The 2nd table in the page describes Transport stream ID and Original network ID of each channel (see Figure 25). Each
stream in a network must have unique ID, called „Transport stream ID“. An Original_Network_ID is dened as the “unique
identier of a network”. It can be linked to Network ID or used value from this location:
http://www.dvbservices.com/identiers/original_network_id?page=1
Figure 25. Transport stream and original network IDs
Figure 26. Description of other streams in the network
Every channel in the network must be described in NIT. Otherwise TV automatic channel tuning function will not nd all
channels. All modules in the network will be monitored via standard SSDP protocol. NIT tables will be regenerated if any
change is detected in other modulators with the same Network ID. Make sure, that Ethernet router is congured properly to
pass SSDP packets (239.255.255.250:1900 and 239.255.255.246:7900). Also make sure that all modules are connected to
the same Ethernet network.
NOTE: If in the RF network exists transponders that are generated by old TERRA transmodulators/modulators, the
frequencies and modulation parameters must be lled manually (Figure 26).
13
6.6. RF outputs
Two adjacent adjacent QAM (DVB-C output) channels can be congured in this section. There is requirement for channels
to be adjacent and sorted by frequency, see Figure 23 "RF output settings (DVB-C output)". Each channel can have its own
constellation QAM-16/32/64/128/256 (DVB-C output), symbol rate 3500..7200 Mbps. Note, that symbol rates higher than
6956 kSym/s will exceed 8 MHz bandwidth, so these symbol rates should be used carefully.
Figure 27. RF output settings (DVB-C output)
"Output frequency“ parameter can be entered manually or selected as a channel from combobox. Channels that can be
selected from the list depend on which region is selected, see the 6.11.10 "Regions". If you need any other frequency –
select “Manual” and type the needed frequency. Frequency step is 0.1 MHz. „Enable“ checkbox will enable channel to the
output. Global attenuator can be entered up to 15 dB. Also there is individual precise attenuator up to 2.5 dB in step of 0.5 dB.
Press „Update“ to change settings. In case, if any modulation parameter was changed, both channels will be restarted
with new settings. Exception is „Attenuator“, changes in this parameter will not restart the modulator.
6.7. SNMP settings
Figure 28 "SNMP settings" table is located in “IP parameters” tab.
The description of the SNMP conguration parameters:
"Read Community" - community name acts as a password that is shared by multiple SNMP agents and one or more SNMP
managers. "Read Community" password is used for read-only access to the modules parameters.
"Write Community" - is the password used for read-write access to the modules parameters.
"Enable TRAP" - SNMP traps are alerts generated by agents on a managed device. Check this box to enable TRAP
generation. The module generates traps when the diagnostic message occurs.
"TRAP Community" - is the password used for accessing of TRAPS.
"Host IP #1","Host IP #2""Host IP #3" - IP addresses of hosts with SNMP managers, where TRAPS will be send.
Figure 28. "SNMP settings" table
14
6.8 IP settings
All device IP settings can be congured here IP address, subnet mask, gateway,
DNS (Domain Name System), see Figure 29. Starting with software version 1.41,
the “WEB port” number can be customized. Default is 80. You must restart the
device for the port change to take eect. All other IP parameters will be updated
immediately after pressing „Update“ button and redirected to new location.
NOTE: Press the RESET and default IP button [7] for more than three seconds
to set default IP address of the control Ethernet interface (see Figure 1). Ethernet
led indicators "activity" [5] and "link" [6] will start to toggle to inform, that the reset
IP address request has been accepted. Device will be restarted with default IP
address.
To restore all parameters to default values (including password), keep pressing the
button for additional 4 seconds. The green (link) indicator will start blinking after
that time indicating, that a “restore defaults” command has been accepted. Now
the button can be released. Yellow (activity) indicator will light on while resetting
parameters. After that device will restart with all default values.
6.9 E-mail-settings
The device can send e-mail reports if errors were detected. SMTP
protocol is used for that. Figure 30 “E-mail-settings table” shows
parameters related to this feature. “Enable e-mail error report”
checkbox enables error monitoring. All errors within “timeout” period
will be gathered, and send to the e-mail address, provided in “Receiver
e-mail address” input box. Comma separated e-mail addresses can be
used to send report to multiple addresses. The timer will be started as
soon, as the rst error is detected, and stopped when e-mail is sent.
The timer will be restarted again if a new error will appear.
“Sender e-mail address” can be used as authentication in the SMTP
server side.
SSL (SMTPS) protocol is not supported.
Figure 30. E-mail-settings table
6.10 CAM settings
Figure 31. Conguration of CA modules
Figure 29. IP settings table
15
Figure 32. CAM conguration
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
CAM position on output, individual CAM-s
qq
qq
CAM position on input, individual CAM-s
qq
TS Multiplex &
processing
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
CAM 1
CAM 2
q
q
q
q
q
q
TS Multiplex &
processing
CAM 1
CAM 2
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
CAM position on output, CAM-s chained on Line 1
q
qq
TS Multiplex &
processing
CAM 1
q
CAM 2
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
CAM position on output, CAM-s chained on Line 2
q
q
q
TS Multiplex &
processing CAM 1
q
CAM 2
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
CAM position on input, CAM-s chained on Line 1
TS Multiplex &
processing
q
q
CAM 1
q
CAM 2
CAM position on input, CAM-s chained on Line 2
q
q
CAM 1
q
CAM 2
qq
SAT
INPUT
q
Demodulator 1
Demodulator 2
q
Up
converter
q
q
DVB-C
output
q
q
q
Modulator 1
Modulator 2
TS Multiplex &
processing
q
q
Conguration settings and information about CA modules is split into dierent tabs. Most important table “Conguration of
CA modules” can be found in “CAM conf.” tab. In the "Conguration of CA modules" table CAM restart function in case of
descrambling error can be enabled. It is recommended to turn o this option if not activated conditional access card has been
inserted. “CAM settings” and “CAM position” parameters changes the ow of TS. Demod.1 and Demod.2 streams can be
descrambled separately by selecting “Invidual CAM-s” or “Сhained on the line 1” or 2 as shown in Figure 32. CAM position
can be changed from output to input.
For example: “CAM position” is set to “on input” and “CAM settings” is set to “Chained on line #1”. This means that Demod.1
input’s stream travels through CAM 1 followed by CAM 2, then goes to multiplexer and nally to Modulator, see Figure 32.
16
Figure 33. CA information and menu tables
6.11 System menu
This menu tab contains following submenu items: “Event logs”, “Export parameters”, “Import parameters”, “Firmware
upgrade”, “User management”, “Restore defaults“, “ Reset the device“, “Time, Date”, “Language”. Mouse over to show the
list of this submenu.
6.11.1 Event logs
Various important events, errors, warnings will be logged into the system, see Figure 34 "Event logs". Each record has
an event type, which can be used to lter particular messages. Just select checkboxes in the „Logs ltering“ table and press
„Apply“. Other messages will be hidden.
„Erase logs“ button will erase all logs from the system.
“Export logs” button forms the le (log.html) which will be downloaded to PC.
Each record has a log time when the event appeared. Refer to 6.11.8 "Date and time settings" for instructions how to
congure time settings.
Figure 34. Event logs
The content of the remaining tables depends on the inserted CA module (refer to Figure 33 "CA information and menu
tables"). General information about inserted CA module is displayed in the “CA module information” table. When there is no
CA module inserted, "Status" line indicates message: "No module inserted" and remaining lines are empty. Otherwise, the
"Status" contains message "Initialized" and remaining lines are lled with information read from the CA module. As in the
example Figure 33 "CA information and menu tables", "CA module menu" table shows the menu for a particular CAM. Click
on the corresponding button to access dierent menu options. Click on the "Back" button to return to previous menu, click
on the "Home" button to return to start menu.
17
6.11.2 Export parameters
All settings of transmodulator can be exported for backup or copying to another device. Press “Export parameters” and
“parameters.xml” le will be downloaded to PC. This le can be imported only to the same type of device.
6.11.3 Import parameters
Exported parameters can be imported back to the device. Press onto “Click to select le” button (see Figure 35 "Import
parameters") to select exported le.
Figure 35. Import parameters
Press “Upload” button to send the le to the device.It will take several seconds to update all parameters after le upload.
After that, device will function with new conguration. No restart is required.
6.11.4 Firmware upgrade
Device rmware can be upgraded via web browser. Press the “Click to select le” button and select rmware binary le. If
valid le was selected, a version number of new rmware will be displayed. Otherwise an error message will appear. Press
the “Upload” button to upload new rmware to the device. Upload progress bar will appear and may take several seconds
to upload, depending on the size of a le and a network connection speed. A message will be displayed asking to restart
the device when the le was sent to the device. New rmware will be programmed into the device only after restart. It may
take additional minute or more to ash new program. Device will start up with a new rmware and continue to operate with
previous parameters. Additional new rmware features (if any) may need to setup additionally to take eect.
Avoid power supply interruption when a programming process is going on.
Device has possibility to load software revision history and check availability for new software release. Click the “Check
online” link. If computer (not device!) has internet access, it will show a list of all software releases with links to binary les.
Binary le can be downloaded and saved to computer (see Figure 36 "Firmware upgrade"). After that, use the rmware
upgrade method as described above.
Figure 36. Firmware upgrade
18
6.11.5 User management
User may change a password here. Length of the password is up to 16 symbols. Type current password and double enter
new password to change it.
If logged in user has admin role, new users can be added (see Figure 37 "User management").
Figure 37. User management
Enter it’s username, password, select a role and press „Add“ button.
Only administrator (user with a role „admin“) may manage other users.
NOTE: By giving your personal password or user access account for another person, you take full responsibility for all
module settings modications made by that person or anyone else they may give the password to.
6.11.6. Restore defaults
All parameters will be restored back to factory defaults after conrmation. The exception – IP address and users – these
parameters will be unchanged. To restore IP address and system password to system defaults, see „RESET“ button at
section 3, pos.7.
Several seconds can take to restore all parameters, so be patient.
6.11.7. Restart the device
Device will be restarted after conrmation to do it. This is an alternative to pressing a RESET“ button when the device
is operating.
6.11.8. Date, Time
System time can be congured manually or taken from NTP server (only if module can access NTP server). Also there is
an option to select the time source from TS as shown in the Figure 38.
Figure 38. "Date, Time" settings table
6.11.9. Language
Device control panel supports several preinstalled languages. A change of language requires system restart. Note, that
all previously logged records will remain in previous language.
Additional languages can be installed under request. Contact our distributors for such possibility.
6.11.10. Regions
Device supports several preinstalled regions. Region can be changed without restarting the device, just select needed
region by pressing “Change” button in “Device information” table. The RF channel list depends on which region is selected.
Additional regions can be installed under request. Contact our distributors for such possibility.
19
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37
-
31 34 44, fax: +370 37
-
31 35 55
E-mail: [email protected], http://www.terraelectronics.com
* supports physical layer scrambling (PLS) and multiple input streams (MIS)
** only in v.1 and v.2 versions
Type tdq420C / tdq420 ttq420C / ttq420
RF input frequency range 950-2150 MHz 47-862 MHz
LNB/preamplifier 0/13/18 V & 22 kHz, 1 A** max. 12 V 100 mA
powering/control DiSEqC 1.0, EN50607, EN50494
level / impedance 45-85 dBµV / 75 W 40-80 dBµV / 75 W
loop through gain -1 ± 1 dB 0 ± 1 dB
standard DVB-S DVB-S2* DVB-T DVB-T2 DVB-C
modulation QPSK QPSK, 8PSK QPSK, QAM16, QPSK, QAM16, QAM16, QAM32,
APSK 8/16/32 QAM64 QAM64, QAM256 QAM64, QAM128,
QAM256
bandwidth - - 7 MHz, 8 MHz 7 MHz, 8 MHz -
symbol rate 2 ÷ 45 Ms/s 2 ÷ 45 Ms/s - - 1 ÷ 7.2 Ms/s
code rate 1/2, 2/3, 3/4, QPSK 1/2, 3/5, 2/3, 1/2, 2/3, 3/4, 1/2, 3/5, 2/3, 3/4,
-
5/6, 7/8 3/4, 4/5, 5/6, 8/9, 9/10 5/6, 7/8 4/5, 5/6
8PSK 3/5, 2/3, 3/4,
5/6, 8/9, 9/10
roll off 35 % 20 %, 25 %, 35 % - - 15 %
RF output standard DVB-C / J.83B
modulation QAM16/QAM32/QAM64/QAM128/QAM256 (DVB-C), QAM64/QAM256 (J.83B)
frequency range 100 - 858 MHz, by step 100 kHz
channel allocation adjacent
level / impedance 90 ± 2 dBµV / 75 W
return loss 14 dB at 47 MHz; -1.5 dB/oct., but not less 10 dB
spurious level < -60 dB
MER 40 dB
channel bandwidth 4...8.3 MHz
symbol rate 3.5 ÷ 7.2 MS/s
roll off 15 %
signal processing EN 300 429, J.83 A (Annex A)
total output level 0 ÷ -15 dB by 1 dB step
adjustment range
loop through frequency 47-2150 MHz / 2.5 dB
range/loss
Transport max. bit rate output 53 Mbps
stream max. PID filter count unlimited
parameters
Management port standard IEE802.3 10/100 Base T
Supply voltage 12 V ±1 V
Current consumption 550 mA 650 mA
without external load
Current consumption 3 A 0.8 A
with maximum external load
Current consumption with maximum 3.6 A - 1.1 A -
CAM-s and external load
Operating temperature range 0o ÷ +50o C
Dimensions/Weight (packed) 48.5x198x112 mm/0.9 kg
7. Technical specications
pr.
pr.
pr.
pr.
pr.
pr.
pr.
pr.
pr.
pr.
pr. software control
1
Сдвоенные DVB-S/S2/S2X & DVB-T/T2/C в DVB-C/J.83B трансмодуляторы
tdq420C, ttq420C, tdq420, ttq420 RU
Vers. 1.20
Данный продукт соответствует требованиям Европейской Директивы 2002/96/EC. Устройство должно
быть переработано или утилизировано в соответствии с местными и региональными правилами.
Оборудование предназначено работать в закрытых помещениях.
Данный продукт соответствует следующим нормам Европейского Союза: электромагнитной совместимости EN50083-2,
безопасности EN IEC62368-1 и RoHS EN50581.
Данный продукт соответствует требованиям технических регламентов Таможенного Союза: “Электромагнитная
совместимость технических средств“ ТР ТС 020/2011, “О безопасности низковольтного оборудования“ ТР ТС 004/2011.
Данный продукт соответствует нормам безопасности по стандарту AS/NZS 60065 и нормам электромагнитной совместимости по
стандартам Австралии.
1. Описание изделия
Устройства представляют собой трансмодуляторы с двумя входными каналами, обеспечивающие прием сигналов
в формате модуляции DVB-S/S2/S2X (модели tdq420C и tdq420) или DVB-T/T2/C (модели ttq420C и ttq420), и двумя
выходными каналами для передачи сигналов в формате модуляции DVB-C/J.83B. Устройства предназначены для
цифровой трансмодуляции с обработкой транспортного потока теле- и радиопрограмм, передаваемых методом (FTA)
открытого или кодированного цифрового вещания. В последнем случае необходимо использовать модуль условного
доступа с картой оператора связи. Процессор модулей обеспечивает фильтрацию программ, внесение изменений
в сведения о программах, генерирование NIT (таблиц сетевой информации) и LCN (номеров логических каналов),
перемаркирование временных отметок программ. Все параметры конфигурации могут быть изменены с помощью
Web интерфейса.
tdq420Cтрансмодулятор с двумя входными каналами для приема сигналов в формате DVB-S/S2/S2X и двумя
выходными каналами для передачи сигналов в формате DVB-C/J.83B и двумя модулями условного доступа;
ttq420C трансмодулятор с двумя входными каналами для приема сигналов в формате DVB-T/T2/C и двумя
выходными каналами для передачи сигналов в формате DVB-C/J.83B и двумя модулями условного доступа;
tdq420 трансмодулятор с двумя входными каналами для приема сигналов в формате DVB-S/S2/S2X и двумя
выходными каналами для передачи сигналов в формате DVB-C/J.83B;
ttq420 трансмодулятор с двумя входными каналами для приема сигналов в формате DVB-T/T2/C и двумя
выходными каналами для передачи сигналов в формате DVB-C/J.83B.
Трансмодуляторы могут использоваться как автономно действующие устройства.
Изделия предназначены для установки и использования внутри помещений.
2. Инструкция по электробезопасности
Инсталляция трансмодулятора должна быть проведена в соответствии с требованиями IEC60728-11 и национальных
стандартов безопасности.
Ремонтировать трансмодулятор может только квалифицированный персонал.
Не устанавливайте трансмодулятор в местах, где есть возможность попадания брызг или капель воды.
Не ставьте сосудов (напр. ваз) с водой или другими жидкостями вблизи трансмодулятора, чтобы избежать попадания
жидкостей внутрь трансмодулятора.
Не устанавливайте трансмодулятор вблизи приборов отопления, а также в помещениях повышенной влажности.
Держите трансмодулятор вдали от открытого огня.
После длительного хранения трансмодулятора при низкой температуре, необходимо перед включением выдержать
его в теплом помещении не менее двух часов.
Не закрывайте трансмодулятор посторонними предметами, напр. газетами, шторами;
При инсталляции крепите трансмодулятор в вертикальном положении. При инсталляции модуля в 19''
коммутационную стойку, может понадобится дополнительный вентиляторный блок для охлаждения модулей (см.
таблицу ''Технические характеристики'' - диапазон рабочих температур.)
Сверху, cпереди и cнизу установленного трансмодулятора должно быть не менее 10 см свободного
пространства.
руководство