Tripp Lite SNMPWEBCARD Инструкция по установке

Категория
Источники бесперебойного питания (UPS)
Тип
Инструкция по установке
Installation Manual
WARRANTY
REGISTRATION
Register online today for a
chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
SNMP/Web Management Accessory Card
Model: SNMPWEBCARD
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Read this manual carefully before installation. A separate User's Guide
(PDF format) is included on the CD-ROM bundled with the accessory card.
Refer to the User's Guide for additional information about configuration
and operation.
200907010 93-2916.indb 1 10/8/2009 5:16:36 PM
2
Warning: When handling the SNMPWEBCARD, follow standard ESD
(electrostatic discharge) precautions to avoid damaging the card. For your
safety, you should also read the documentation that came with your UPS system
or PDU to familiarize yourself with precautions against electric shock.
The SNMPWEBCARD allows users to operate any compatible Tripp Lite UPS
System or network-enabled PDU as a managed device on the network, accessible
via Web browser, Network Management Station or telnet. This manual refers to
installing the card in a UPS system, but the same instructions apply to installing
the card in a compatible PDU.
Installation
1 - Preparation
1-1
Confirm Package Contents: In addition to this manual, your package
should include the accessory card in an anti-static bag, a configuration cable
(73-1025), several faceplates and a CD-ROM containing additional
documentation and Management Information Base (MIB) files for use with
Network Management Systems (not otherwise required). If anything is
missing, contact your supplier immediately.
1-2
Install UPS: Install your UPS system and turn it on before installing the
SNMPWEBCARD. Ensure that the accessory card slot is accessible.
1-3
Locate MAC Address: The 12-digit MAC address (000667xxxxxx) is
printed in two locations: a label attached to the underside of the card and a
duplicate label inside the box. Attach the duplicate label to the UPS system
or keep it in a secure location for easy reference.
1-4
Determine Installation Method: If your network's DHCP server will
assign a dynamic IP address to the SNMPWEBCARD automatically,
proceed to 2 - Dynamic IP Address Assignment. If you will assign a static
IP address to the SNMPWEBCARD manually, proceed to 3 - Static IP
Address Assignment. If you are uncertain which method to use, contact
your network administrator for assistance before continuing the installation
process.
200907010 93-2916.indb 2 10/8/2009 5:16:36 PM
3
Installation
2 - Dynamic IP Address Assignment
2-1
Insert SNMPWEBCARD in Accessory Slot: Use a screwdriver to remove
the accessory slot cover from the UPS. While the UPS is turned on, align
the SNMPWEBCARD with the guides in the accessory slot and push the
card into the slot until the ports are nearly even with the rear surface of the
UPS.
2-2
Connect SNMPWEBCARD to Network: Connect a standard Ethernet
patch cable to the RJ-45 Ethernet port on the card. Note: This port does not
support PoE (Power over Ethernet) applications. The card will attempt to
obtain an IP address via DHCP. This may take as long as several minutes,
depending on your network environment.
2-3
Discover IP Address: Contact your network administrator to determine
which IP address has been assigned to the card by the DHCP server. The
card can be identified on the DHCP server by referring to its MAC address
(see Step
1-3
). You may wish to request a long-term lease period for the IP
address, depending on your application. After you have discovered the IP
address, proceed to 4 -Test and Configure. Note: The DHCP addresss is
also displayed during boot-up when connected to a computer through the
configuration cable and a terminal emulation program.
3 - Static IP Address Assignment/Terminal Menu
Configuration Settings
3-1
Determine IP Information: Before assigning a static IP address, you'll
need to know the IP address, gateway address and subnet mask. If you do
not have this information, contact your network administrator for assistance.
200907010 93-2916.indb 3 10/8/2009 5:16:36 PM
4
If the terminal emulation program supports multiple emulation modes, you
may also need to specify VT100 emulation
C
.
A
B
C
3-2
Configure Terminal Emulation Program: Open a VT100-compatible
terminal emulation program (such as the HyperTerminal program bundled
with Microsoft
®
Windows
®
) on a computer with an available DB9 serial
port. (A notebook computer may be the most convenient choice.) Set the
terminal emulation program to use the COM
port
A
that corresponds to the DB9 serial port.
Specify the parameters
B
required to
communicate with the SNMPWEBCARD
terminal interface:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Installation
Note: The following message will appear in the terminal startup menu:
IAM:Got AUTO-CONFIGURED IPv6 address FE80::4200:FF:FE01:8 on interface
eth0:3
IPv6 is not currently supported. Tripp Lite is working on IPv6 for a future
release.
200907010 93-2916.indb 4 10/8/2009 5:16:37 PM
5
3-4
Connect SNMPWEBCARD to Computer: Use the mini-DIN to DB9
serial cable (part number 73-1025) included with the card to connect the
card to the computer. The circular connector
A
at one end of the cable
attaches to the 8-pin mini-DIN serial port
B
on the card. (Align the
connector carefully to avoid damaging the pins.) The DB9 connector
C
at
the other end of the cable connects to the computer's serial port
D
.
A
B
C
D
3-5
Connect SNMPWEBCARD to Network: Connect a standard Ethernet
patch cable to the RJ-45 Ethernet port on the card. Note: This port does not
support PoE (Power over Ethernet) applications.
3-6
Configure SNMPWEBCARD in Terminal Mode: After a brief pause, an
initialization page should appear in the terminal emulation program. Press
any key on the keyboard within 5 seconds to change the card's settings. (If
the 5-second period has elapsed, you can reboot the card by removing it and
then re-seating it in the accessory slot.)
Installation
3-3
Insert SNMPWEBCARD in Accessory Slot: Use a screwdriver to remove
the accessory slot cover from the UPS. While the UPS is turned on, align the
SNMPWEBCARD with the guides in the accessory slot and push the card
into the slot until the ports are nearly even with the rear surface of the UPS.
200907010 93-2916.indb 5 10/8/2009 5:16:38 PM
6
Follow the sequence of responses below in order to assign an IP address to
the card. The default terminal mode password is TrippLite. Sample IP
settings are shown - supply your own IP information when you configure
your card.
Installation
This card’s hostname [ ]?
This card’s domain [ ]?
Obtain IP settings automatically using DHCP for Ethernet interface? [Y]
IP address? [10.2.0.98]
Subnet mask? [255.0.0.0]
Gateway address? [10.0.0.1]
DNS server 1? [10.0.0.5]
DNS server 2? [10.2.0.10]
This cards host name? [cornflakes]
This cards domain? [tlsoftwaredev.local]
SNMP Settings
Enable SNMP Community 0 [Y]? y
Choose a community privilege level:
0 - noAccess
1 - v1UserReadOnly
2 - v1UserReadWrite
3 - v2cUserReadOnly
4 - v2cUserReadWrite
Privilege Level [4]:
Community Name [tripplite]:
Allowable Address Range : [0.0.0.0]?
Allowable Address Mask : [0.0.0.0]?
Enable SNMP Community 1 [N]? n
Enable SNMP Community 2 [N]? n
Enable SNMP Community 3 [N]? n
Note: Default SNMP access is:
Community 0 enable with v2 read only community public
Community 1 enable with v2 read/write community tripplite
200907010 93-2916.indb 6 10/8/2009 5:16:38 PM
7
Additional Settings
Additional Ethernet Settings:
Enable SNTP? [N]
Enable http? [Y]
Port number? [80]
Hardware Parameters:
Would you like to update the RTC date/time in GMT? [N]
Time Zone (0 is GMT-12, 6 is CST) :
Time Zone Offsets Supported
Western Hemisphere Eastern Hemisphere
Hour
Off-Set Location
Hour
Off-Set Location
0 Greenwich, England -1 Mid Europe/Africa
1 SE Greenland -2 E Europe, E Central Africa
2 Atlantic Ocean -3 Moscow, Mid-East, E Africa
3 Greenland Time -4 NW Caspian Sea
4 Atlantic Time -5 Ural Mountains, Russia
5 Eastern Standard Time -6 Almaty (Alma ATA), Russia
6 Central Standard Time -7 W Mongolia
7 Mountain Standard Time -8 China
8 Pacific Standard Time -9 Japan
9 Alaska Time -10 Eastern Russia, Sydney, Australia
10 Hawaii -11 Kamchatskiy, E Russia
11 Pacific Ocean
+/-12 International Date Line
Do you wish to configure the advanced settings [y/n]? [Y]
This interface must have a unique MAC address.
Ethernet MAC Address? [00:06:67:01:00:08]
DO NOT MODIFY UNLESS DIRECTED BY YOUR
ADMINISTRATOR
Do you want to completely erase the file system? [N]
Enable https? [N]
Port number? [443]
Enable telnet? [Y]
Port number? [23]
Enable ssh? [Y]
Port number? [22]
Installation
200907010 93-2916.indb 7 10/8/2009 5:16:38 PM
8
4 - Test and Configure
4-1
Test Network Connection: After an IP address has been assigned to the
card, try to access it with a Web browser that supports frames, forms and
Java
. Open a Web browser on a computer connected to the LAN and enter
the card's IP address. You should be prompted for a password. The user
name is admin and the default password is admin. After you enter the user
name and password, the PowerAlert Status page will appear in the browser
window. For more information about configuration and operation of the
managed device, refer to the SNMPWEBCARD User's Guide, included on
the CD-ROM bundled with the card.
4-2
Default UPS Shutdown Setting: During a loss of utility power, the
SNMPWEBCARD is configured to shut down the UPS system 2 minutes
after a low battery signal is received from the UPS. This allows the UPS to
provide the maximum available runtime to connected equipment. If you
want to change the default setting, follow these instructions:
DO NOT MODIFY UNLESS DIRECTED BY TRIPP LITE
TECHNICAL SUPPORT
Default Ethernet setting (0=Auto, 1=10 Half, 2=10 Full, 3=100 Half,
4=100 Full)? [Auto]
DO NOT MODIFY UNLESS DIRECTED BY YOUR
ADMINISTRATOR
You can also change the root password, real-time clock and other settings.
(Tripp Lite recommends against changing the default settings unless you are
an advanced user with a specific purpose.) After you have finished entering
settings, the card will save changes to memory and reboot (this may take
several minutes). After the card reboots, the initialization page should
display the new static IP settings.
3-7
Remove Serial Cable: Using one hand to hold the card in place, remove the
serial cable. Proceed to 4 -Test and Configure.
Installation
200907010 93-2916.indb 8 10/8/2009 5:16:38 PM
9
1. From the initial PowerAlert Status page, click the Settings button
A
at the
top of the screen, then click the Events button
B
that appears at the left
side of the screen.
2. From the Event Settings page, confirm that the Low Battery
C
and
Shutdown
D
box is checked and then click the Details Tab
E
, or double-
click the checked box to access the Setting Details page.
3. From the Details page
F
, choose your preferred settings from the
Settings drop down menu
G
and click the Save Changes button
H
.
AB C DE
FG H
Installation
4-3
Attach Faceplate: Using one hand to hold the card in place, temporarily
detach the network cable. Align and attach the faceplate that matches your
UPS system, using screws from the accessory slot cover. Reattach the
network cable.
Note for Network Management System Users Only: Two MIB files -
Tripplite.mib and RFC1628.mib - must be loaded on each Network
Management Station that will monitor the UPS system via SNMP. The files
are provided on the CD-ROM included in the product package.
200907010 93-2916.indb 9 10/8/2009 5:16:39 PM
10
Features
A
PS/2 Port: Use this port to connect a Tripp Lite ENVIROSENSE
environmental sensor to provide remote temperature/humidity monitoring
and a dry contact interface to control and monitor alarm, security and
telecom devices. Contact Tripp Lite Customer Support at (773) 869-1234
for ordering information. Note: Do not connect a keyboard or mouse to this
port.
B
Mini-DIN Serial Port: Use this port to provide a direct terminal connection
to a computer with a terminal emulation program. A serial cable (part
number
73-1025) is included with the SNMPWEBCARD. If you need to order a
replacement cable, contact Tripp Lite Customer Support at (773) 869-1234.
C
Ethernet Port: Use this RJ-45 jack to connect the SNMPWEBCARD to
the network with a standard Ethernet patch cable. The Link LED
C1
and
Status LED
C2
indicate several operating conditions, as shown in the table
below. Does not support PoE (Power Over Ethernet) applications.
A B
C
C1 C2
SNMPWEBCARD Operating Conditions
C1
Link LED Color
Off No Network Connection
Flashing Amber 100 Mbps Network Connection
Flashing Green 10 Mbps Network Connection
C2
Status LED Color
Off Card Not Initialized
Steady Green Card Initialized and Operational
Flashing Amber Error - Card Not Initialized
200907010 93-2916.indb 10 10/8/2009 5:16:39 PM
11
Technical Support
Technical Support can be found at: www.tripplite.com/support
Warranty and Warranty Registration
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and
workmanship for a period of 2 years (except internal UPS system batteries outside USA and Canada, 1 year) from the date of initial
purchase. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product,
in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or
delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609, USA. Seller will pay return shipping charges. Visit
www.tripplite.com/support before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR
NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN.
EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS
WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations
on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights
which vary from jurisdiction to jurisdiction).
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use
intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the
suitability or fitness of these devices for any specific application.
Not compatible with PoE (Power over Ethernet) applications.
WARRANTY REGISTRATION
Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a
drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
FCC Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not
expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series
number. The series number can be found on the product nameplate label, along with all required approval markings and information.
When requesting compliance information for this product, always refer to the series number. The series number should not be confused
with the marking name or model number of the product.
Tripp Lite has a policy of continuous improvement. Product specifications are subject to change without notice.
200907010 • 932916-EN
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
200907010 93-2916.indb 11 10/8/2009 5:16:39 PM
12
Manual de instalación
Tarjeta accesoria para administración SNMP/Web
Modelo: SNMPWEBCARD
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Lea cuidadosamente este manual antes de la instalación. Una Guía del
Usuario por separado (en formato PDF) se incluye en el CD-ROM que
acompaña a la tarjeta accesoria. Consulte la Guía del usuario para obtener
información adicional acerca de la configuración y la operación.
200907010 93-2916.indb 12 10/8/2009 5:16:40 PM
1313
Advertencia: Cuando manipule la SNMPWEBCARD, siga las precauciones estándar de
descarga electrostática (electrostatic discharge, ESD) para evitar daños a la tarjeta. Para
su seguridad, también debe leer la documentación que acompaña su sistema UPS o PDU
con el fin de familiarizarse con las precauciones para evitar descargas eléctricas.
La SNMPWEBCARD permite que los usuarios operen cualquier Sistema UPS o PDU
habilitado para red compatible con Tripp Lite como un dispositivo administrado en la red,
al que se puede acceder a través de un navegador Web, de una Estación de Administración
de Red o de telnet. Este manual se refiere a la instalación de la tarjeta en un sistema UPS,
pero las mismas instrucciones se aplican a la instalación de la tarjeta en un PDU
compatible.
Instalación
1 - Preparación
1-1
Confirme el contenido del paquete: Además de este manual, su paquete debe
incluir la tarjeta accesoria en una bolsa antiestática, un cable para la configuración
(73-1025), varias placas frontales y un CD-ROM que contiene documentación
adicional y archivos de Base de Administración de Información (MIB) para
utilizarlos con los Sistemas de Administración de Red (si no se requiere otra cosa).
En caso de que falte algo, contacte a su proveedor de inmediato.
1-2
Instale el UPS: Instale su sistema UPS y enciéndalo antes de instalar la
SNMPWEBCARD. Asegúrese de que la ranura para la tarjeta accesoria sea accesible.
1-3
Localice la dirección MAC: La dirección MAC de 12 dígitos (000667xxxxxx) está
impresa en dos lugares: en una etiqueta pegada en la parte inferior de la tarjeta y en
una etiqueta duplicada adentro de la caja. Pegue la etiqueta duplicada en el sistema
UPS o manténgala en un lugar seguro para que pueda consultarla con facilidad.
1-4
Determine el método de instalación: Si el servidor DHCP de su red le asignará
automáticamente una dirección IP dinámica a la SNMPWEBCARD, proceda con 2 -
Asignación de una dirección IP dinámica. Si usted le va a asignar manualmente una
dirección IP estática a la SNMPWEBCARD, proceda con 3 - Asignación de una
dirección IP estática. Si no está seguro de cuál método usar, contacte a su
administrador de red en busca de ayuda antes de continuar con el proceso de
instalación.
200907010 93-2916.indb 13 10/8/2009 5:16:40 PM
1414
Instalación
2 - Asignación de una dirección IP dinámica
2-1
Inserte la SNMPWEBCARD en la ranura para la tarjeta accesoria: Utilice un
desarmador para retirar la cubierta de la ranura para la tarjeta accesoria del UPS. Con
el UPS encendido, alinee la SNMPWEBCARD con las guías de la ranura para la
tarjeta accesoria y empuje la tarjeta en la ranura hasta que los puertos estén casi
emparejados con la superficie posterior del UPS.
2-2
Conecte la SNMPWEBCARD a la red: Conecte un cable patch Ethernet estándar al
puerto Ethernet RJ-45 A en la tarjeta. Nota: Este puerto no soporta aplicaciones PoE
(Energía sobre la Ethernet). La tarjeta intentará obtener una dirección IP a través de
DHCP. Esto podría requerir de varios minutos, dependiendo de su entorno de red.
2-3
Descubra la dirección IP: Contacte a su administrador de red para determinar cuál
es la dirección IP que el servidor DHCP le asignó a la tarjeta . La tarjeta puede ser
identificada en el servidor DHCP haciendo referencia a su dirección MAC (vea el
paso
1-3
). Tal vez quiera solicitar un periodo de uso más prolongado para la dirección
IP, dependiendo de su aplicación. Después de que haya descubierto la dirección IP,
vaya a 4 –Prueba y configuración. Nota: La dirección DHCP también se muestra
durante el inicio, cuando se conecta a una computadora a través del cable de
configuración y de un programa de emulación de terminal.
3 - Asignación de una dirección IP estática/Ajustes del
menú de la terminal
3-1
Determine la información IP: Antes de asignar una dirección IP estática, necesitará
conocer la dirección IP, la dirección de entrada (gateway) y la máscara de subred. Si
no tiene esta información, comuníquese con su administrador de red para obtener
asistencia.
200907010 93-2916.indb 14 10/8/2009 5:16:40 PM
1515
Si el programa de emulación de terminal soporta diversos modos de emulación,
también necesitará especificar la emulación VT100
C
.
A
B
C
Bits por segundo: 9600
Bits de datos: 8
Paridad: Ninguna
Bits de parada: 1
Control de flujo: Ninguno
Instalación
Notas: El siguiente mensaje aparecerá en el menú de inicio de la terminal:
IAM:Got AUTO-CONFIGURED IPv6 address FE80::4200:FF:FE01:8 on interface
eth0:3
IPv6 is not currently supported. Tripp Lite is working on IPv6 for a future
release.
3-2
Configure el Programa de emulación de terminal: En una computadora con un
puerto serial DB9 disponible, abra un programa de emulación de terminal compatible
con VT100 (como el programa HyperTerminal que se incluye en Microsoft
®
Windows
®
). (Una computadora portátil podría ser la opción más adecuada.) Configure
el programa de emulación de terminal para que use el
puerto COM
A
que corresponde al puerto serial DB9.
Especifique los parámetros
B
requeridos para
comunicarse con la interfaz de terminal de la
SNMPWEBCARD:
200907010 93-2916.indb 15 10/8/2009 5:16:41 PM
1616
3-4
Conecte la SNMPWEBCARD a la computadora: Para conectar la tarjeta a la
computadora utilice el cable serial mini-DIN a DB9 (número de parte 73-1025) que
se incluye con la tarjeta. El conector circular
A
de uno de los extremos del cable se
conecta al puerto serial mini-DIN de 8 pines
B
de la tarjeta. (Alinee el conector con
cuidado para evitar dañar los pines.) El conector DB9
C
que se encuentra en el otro
extremo del cable se conecta al puerto serial
D
de la computadora.
A
B
C
D
3-5
Conecte la SNMPWEBCARD a la red: Conecte un cable patch estándar al puerto
Ethernet RJ-45 de la tarjeta. Nota: Este puerto no soporta aplicaciones PoE (Energía
sobre la Ethernet).
3-6
Configure la SNMPWEBCARD en el modo de terminal: Después de una breve
pausa, deberá aparecer una página de inicialización en el programa de emulación de
terminal. Oprima cualquier tecla del teclado antes de 5 segundos para cambiar los
ajustes de la tarjeta. (Si pasa el periodo de 5 segundos, podrá reiniciar la tarjeta
retirándola y volviéndola a colocar en la ranura accesoria.)
Instalación
3-3
Inserte la SNMPWEBCARD en la ranura accesoria: Use un desarmador para
quitar la tapa de la ranura accesoria del UPS. Mientras el UPS está encendido, alinee
la SNMPWEBCARD con las guías de la ranura accesoria y empuje la tarjeta dentro
de la ranura hasta que los puertos estén casi emparejados con la superficie posterior
del UPS.
200907010 93-2916.indb 16 10/8/2009 5:16:41 PM
1717
Siga en orden la secuencia de respuestas que se muestra abajo para asignarle una
dirección IP a la tarjeta. La contraseña predeterminada para el modo de terminal es
TrippLite. Aquí se ofrecen valores IP de muestra; introduzca su propia información IP
cuando configure su tarjeta.
Instalación
This card’s hostname [ ]?
This card’s domain [ ]?
Obtain IP settings automatically using DHCP for Ethernet interface? [Y]
IP address? [10.2.0.98]
Subnet mask? [255.0.0.0]
Gateway address? [10.0.0.1]
DNS server 1? [10.0.0.5]
DNS server 2? [10.2.0.10]
This cards host name? [cornflakes]
This cards domain? [tlsoftwaredev.local]
Ajustes de SNMP
Enable SNMP Community 0 [Y]? y
Choose a community privilege level:
0 - noAccess
1 - v1UserReadOnly
2 - v1UserReadWrite
3 - v2cUserReadOnly
4 - v2cUserReadWrite
Privilege Level [4]:
Community Name [tripplite]:
Allowable Address Range : [0.0.0.0]?
Allowable Address Mask : [0.0.0.0]?
Enable SNMP Community 1 [N]? n
Enable SNMP Community 2 [N]? n
Enable SNMP Community 3 [N]? n
Nota: El acceso predeterminado a SNMP es:
Community 0 enable with v2 read only community public
Community 1 enable with v2 read/write community tripplite
200907010 93-2916.indb 17 10/8/2009 5:16:41 PM
1818
Ajustes adicionales
Ajustes adicionales de Ethernet:
Enable SNTP? [N]
Enable http? [Y]
Port number? [80]
Parámetros de hardware:
Would you like to update the RTC date/time in GMT? [N]
Time Zone (0 is GMT-12, 6 is CST) :
Compensaciones de zona horaria soportadas
Hemisferio occidental Hemisferio oriental
Compen-
sación
horaria Ubicación
Compen-
sación
horaria Ubicación
0 Greenwich, Inglaterra -1 Europa central/África
1 SE Groenlandia -2 Europa del este, África Central y del
Este
2 Océano Atlántico -3 Moscú, Medio Oriente, África del Este
3 Hora de Groenlandia -4 NO Mar Caspio
4 Hora del Atlántico -5 Montes Urales, Rusia
5 Hora Estándar del Este -6 Almaty (Alma ATA), Rusia
6 Hora Estándar del Centro -7 O Mongolia
7 Hora Estándar de la Montaña -8 China
8 Hora Estándar del Pacífico -9 Japón
9 Hora de Alaska -10 Este de Rusia, Sidney, Australia
10 Hawái -11 Kamchatskiy, Este de Rusia
11 Océano Pacífico
+/-12 Línea internacional de cam-
bio de fecha
Do you wish to configure the advanced settings [y/n]? [Y]
Esta interfaz debe tener una dirección MAC única.
Ethernet MAC Address? [00:06:67:01:00:08]
NO MODIFIQUE ESTO A MENOS QUE SE LO INDIQUE SU ADMINISTRADOR
Do you want to completely erase the file system? [N]
Enable https? [N]
Port number? [443]
Enable telnet? [Y]
Port number? [23]
Enable ssh? [Y]
Port number? [22]
Instalación
200907010 93-2916.indb 18 10/8/2009 5:16:42 PM
1919
4 – Prueba y configuración
4-1
Pruebe la conexión de la red: Después de que se le haya asignado una dirección IP a
la tarjeta, trate de acceder a ella con un navegador Web que soporte marcos, formularios
y Java
. Abra un navegador Web en una computadora conectada a la LAN e introduzca
la dirección IP de la tarjeta. Se le solicitará una contraseña. El nombre de usuario es
admin y la contraseña predeterminada es admin. Después de que introduzca el nombre
de usuario y la contraseña, aparecerá la página PowerAlert Status en la ventana del
navegador. Si desea más información acerca de la configuración y la operación del
dispositivo administrado, consulte la Guía del Usuario de la SNMPWEBCARD que se
incluye en el CD-ROM que acompaña a la tarjeta.
4-2
Ajuste predeterminado de apagado del UPS: Durante una pérdida de energía
eléctrica, la SNMPWEBCARD está configurada para apagar el UPS dos minutos
después de recibir una señal de batería baja desde el UPS. Esto permite que el UPS
proporcione el máximo nivel de tiempo de ejecución disponible para el equipo
conectado. Si quiere cambiar el ajuste predeterminado, siga estas instrucciones:
NO MODIFIQUE ESTO A MENOS QUE SE LO INDIQUE EL SOPORTE
TÉCNICO DE TRIPP LITE
Default Ethernet setting (0=Auto, 1=10 Half, 2=10 Full, 3=100 Half,
4=100 Full)? [Auto]
NO MODIFIQUE ESTO A MENOS QUE SE LO INDIQUE SU
ADMINISTRADOR
También puede cambiar la contraseña de la raíz, el reloj en tiempo real y otros ajustes.
(Tripp Lite no recomienda cambiar los ajustes predeterminados a menos que usted sea
un usuario avanzado y tenga un propósito específico.) Después de que termine de
introducir los ajustes, la tarjeta guardará los cambios en la memoria y reiniciará (esto
puede tardar varios minutos). Después de que la tarjeta reinicie, la página de
inicialización mostrará los nuevos ajustes de la IP estática.
3-7
Retire el cable serial: Usando una mano para mantener la tarjeta en su lugar, retire el
cable serial. Vaya a 4 –Prueba y configuración.
Instalación
200907010 93-2916.indb 19 10/8/2009 5:16:42 PM
2020
1. En la página inicial de estado de PowerAlert, haga clic en el botón Settings (Ajustes)
A
que se encuentra en la parte superior de la pantalla, después haga clic en el botón
Events (Eventos)
B
que aparece en el lado izquierdo de la pantalla.
2. Desde la página Event Settings (Ajustes de Eventos), confirme que el cuadro donde
se juntan Low Battery (Batería baja)
C
y Shutdown (Apagado)
D
esté activado y
después haga clic en la ficha Details (Detalles)
E
, o haga doble clic sobre el cuadro
activado para acceder a la página Setting Details (Detalles de los ajustes).
3. En la página Details (Detalles)
F
, elija sus ajustes preferidos en el menú desplegable
Settings (Ajustes)
G
y haga clic en el botón Save Changes (Guardar cambios)
H
.
Instalación
4-3
Coloque una placa frontal: Usando una mano para mantener la tarjeta en su lugar,
desconecte temporalmente el cable de red. Alinee la placa frontal que coincida con su
sistema UPS usando los tornillos de la cubierta de la ranura accesoria. Vuelva a
conectar el cable de red.
Nota únicamente para los usuarios del sistema de administración de red: Dos archivos
MIB (Tripplite.mib y RFC1628.mib) se deben cargar en cada una de las estaciones de
administración de red que monitorearán el sistema UPS a través de SNMP. Los
archivos se proporcionan en el CD-ROM que se incluye en el paquete del producto.
AB C DE
FG H
200907010 93-2916.indb 20 10/8/2009 5:16:42 PM
1 / 1

Tripp Lite SNMPWEBCARD Инструкция по установке

Категория
Источники бесперебойного питания (UPS)
Тип
Инструкция по установке

Задайте вопрос, и я найду ответ в документе

Поиск информации в документе стал проще с помощью ИИ

Спросите документ